The transponders can be used for the following RFID systems:
- SIMATIC RF200
- SIMATIC RF300 (in ISO 15693 operating mode)
- MOBY D (except MDS D421, MDS D422, MDS D425)
Transponder | Features |
MDS D165 | SmartLabel, (PET) in credit card format. Applications range from simple identification such as electronic barcode substitution or supplementation to storage and distribution logistics, right up to product identification. - 112 bytes EEPROM
- Up to IP65 degree of protection
- Operating temperature range -25 °C to +85 °C
- Dimensions L x W (mm): 86 x 54
|
MDS D261 | SmartLabel, (PET) in compact design. Applications range from simple identification such as electronic barcode substitution or supplementation to storage and distribution logistics, right up to product identification. - 256 bytes EEPROM
- Up to IP65 degree of protection
- Operating temperature range -25 °C to +85 °C
- Dimensions L x W (mm): 55 x 55
|
MDS D100 | Universal transponder in credit card format. - 112 bytes EEPROM
- IP68 degree of protection
- Operating temperature range -25 °C to +80 °C
- Dimensions L x W x H (mm): 85.6 x 54 x 0.9
|
MDS D200 | Universal transponder in credit card format. - 256 bytes EEPROM
- IP67 degree of protection
- Operating temperature range -20 °C to +60 °C
- Dimensions L x W x H (mm): 86 x 54 x 0.8
|
MDS D124 | Rugged transponder for use in harsh industrial environments and under extreme environmental conditions. - 112 bytes EEPROM
- IP68 / IPx9K degree of protection
- Operating temperature range -25 °C to +180 °C
- Dimensions diameter x height (mm): Ø 27 x 4
|
MDS D139 | Heat-resistant transponder for use in paint shops or applications with high thermal stress. - 112 bytes EEPROM
- IP68 / IPx9K degree of protection
- Operating temperature range -25 °C to +220 °C
- Dimensions diameter x height (mm): Ø 85 x 15
|
MDS D160 | The transponder has been specially designed for harsh environments in the laundry and cleaning industry. - Its main applications include:
- Rented work clothing
- Rented laundry
- OP textiles, hospital clothing
- Hotel laundry
- Dirt collection mats
- 112 bytes EEPROM
- IP68 / IPx9K degree of protection
- Operating temperature range -25 °C to +175 °C
- Dimensions diameter x height (mm): Ø 16 x 3
|
MDS D324 | Rugged transponder for use in harsh industrial environments and under extreme environmental conditions. - 992 bytes EEPROM
- IP67 degree of protection
- Operating temperature range -25 °C to +125 °C
- Dimensions diameter x height (mm): Ø 27 x 4
|
MDS D424 | Rugged transponder for use in production and distribution logistics as well as in assembly and production lines: - 2000 bytes FRAM
- IP67 degree of protection
- Operating temperature range -25 °C to +85 °C
- Dimensions diameter x height (mm): Ø 27 x 4
|
MDS D428 | Compact and rugged ISO transponder; suitable for screw mounting; for use in assembly and production lines in the powertrain area. - 2000 bytes FRAM
- IP68 / IPx9K degree of protection
- Operating temperature range -25 °C to +85 °C
- Dimensions diameter x height (mm): Ø 24 x 20 (without M8 grub screw)
|
MDS D460 | Rugged transponder for use in assembly lines. - 2000 bytes FRAM
- IP67 degree of protection
- Operating temperature range -25 °C to +85 °C
- Dimensions diameter x height (mm): Ø 16 x 3
|
MDS D421 | Transponder for tool coding according to DIN 69873. It can be used wherever very small data carriers and exact positioning are required (e.g. for tool identification). - 2000 bytes FRAM
- IP67 / IPx9K degree of protection
- Operating temperature range -25 °C to +85 °C
- Dimensions diameter x height (mm): Ø 10 x 4.5
Note: This transponder is operated exclusively with the following readers/antennas: SIMATIC RF350R with ANT 12 or ANT 18 and SIMATIC RF210R. Operation with the mobile readers (SIMATIC RF310M and MOBY STG D) is not possible. |
MDS D126 | Compact and rugged ISO transponder; suitable for identification of transport units in production-related logistics; can also be used under harsh environmental conditions. - 112 bytes EEPROM
- IP68 degree of protection
- Operating temperature range -25 °C to +85 °C
- Dimensions L x W x H (mm): 85.6 x 54 x 0.9
|
MDS D426 | Compact and rugged ISO transponder; suitable for identification of transport units in production-related logistics; can also be used under harsh environmental conditions. - 2000 bytes FRAM
- IP68 / IPx9K degree of protection
- Operating temperature range -25 °C to +85 °C
- Dimensions diameter x height (mm): Ø 50 x 3.6
|
MDS D422 | Transponder for the identification of metallic workpiece holders, workpieces or containers. - 2000 bytes FRAM
- IP68 degree of protection
- Operating temperature range -25 °C to +85 °C
- Dimensions, thread diameter x height (mm): M20 x 6
Note: This transponder is operated exclusively with the following readers/antennas: SIMATIC RF350R with ANT 12, ANT 18, ANT 30 and SIMATIC RF210R, RF220R. Operation with the mobile readers (SIMATIC RF310M and MOBY STG D) is not possible. |
MDS D425 | Compact and rugged ISO transponder; suitable for screw mounting; for use in assembly and production lines in the powertrain area. - 2000 bytes FRAM
- IP68 / IPx9K degree of protection
- Operating temperature range -25 °C to +85 °C
- Dimensions diameter x height (mm): Ø 24 x 10 (without M6 grub screw)
|
Customer-specific transponder
Customer-specific transponders (packaging, temperature range, geometry, etc.) on request.
Field data (operating/limit distance) of transponders and readers (all specifications in mm)
The following table shows the field data (unaffected by metal) for all ISO transponders (MDS Dxxx) in connection with RF200 readers. The listed technical data are typical values and are valid for a room temperature of +25 °C.
| MDS D165 | MDS D261 | MDS D100 | MDS D200 | MDS D124 | MDS D139 | MDS D160 | MDS D324 |
---|
SIMATIC RF210R | - | - | - | - | 5 … 16/18 | - | 2 … 10/12 | 2 … 8/9 |
SIMATIC RF220R | 10 … 36/44 | 10 … 30/35 | 10 … 35/40 | 10 … 35/40 | 5 … 16/18 | 10 … 35/40 | 5 … 20/22 | 10 … 20/25 |
SIMATIC RF260R | 40 … 120/135 | 20 … 75/90 | 40 … 110/130 | 30 … 100/120 | 10 … 40/48 | 20 … 80/110 | 10 … 40/45 | 20 … 60/70 |
| MDS D424 | MDS D428 | MDS D460 | MDS D421 | MDS D126 | MDS D426 | MDS D422 | MDS D425 |
---|
SIMATIC RF210R | 2 … 10/12 | 2 … 10/12 | 2 … 8/9 | 1 … 2/4 | - | - | 2 … 6/7 | 3 … 7/8 |
SIMATIC RF220R | 10 … 25/28 | 5 … 18/20 | 5 … 18/20 | 1 … 5/6 | 8 … 25/28 | 10 … 30/35 | 3 … 9/10 | 5 … 12/14 |
SIMATIC RF260R | 10 … 60/70 | 5 … 30/40 | 10 … 35/40 | - | 15 … 55/75 | 20 … 70/90 | - | - |
–: Reader-transponder combination not released
For detailed descriptions and detailed technical data of the ISO transponders MDS Dxxx: See MOBY D.