Siemens has developed standardized system solutions that supplement its range of individual system solutions for a wide range of sector-specific applications.
Our system solutions have had outstanding success in practice and are subject to continuous further development.
Set FLK - Continuous sampling of flue gas in cement kiln
Gas analysis in the rotary kiln in cement manufacturing is crucial to the efficient and safe operation of the plant and in protecting against emissions. Sampling the gas in the rotary kiln for analysis purposes can be handled optimally with the FLK gas sampling equipment.
Set GGA - Continuous monitoring of H2-cooled generators
In hydrogen-cooled turbo generators in power plants, the gas mixture is monitored for protection against explosion hazard, and hydrogen purity is determined for economic reasons. A special analysis system with two CALOMAT 6 analyzers has been developed for this task. It complies with the relevant regulations with regard to redundancy and explosion protection.
Set CV - Determining the natural gas quality
The quality of natural gas is determined at different points from gas production, through the distribution network, to the end user. With the Set CV (Calorific Value), Siemens offers a standardized system that covers all the requirements of such applications, from sampling through pressure reduction, sample preparation, determination of quality using the SITRANS CV natural gas chromatograph, supplying carrier and calibration gases, right up to expansion of the communication interfaces.
Set CEM - Continuous monitoring of emission components in flue gases
The measurement and monitoring of emission components in flue gases is one of the most important issues in continuous gas analysis. The Set CEM (Continuous Emission Monitoring) offered by Siemens is a standardized system which reliably covers all requirements associated with sampling, sample preparation, and gas analysis.