SIPLUS CPU 317F-2 DP производства Siemens

SIPLUS CPU 317F-2 DP
  • The fail-safe CPU with a large program memory and quantity framework for demanding applications
  • For configuring a fail-safe automation system for plants with increased safety requirements
  • Complies with safety requirements up to SIL 3 according to IEC 61508 and up to Cat. 4 according to EN 954-1
  • Fail-safe I/O modules can be connected in a distributed configuration to both integral PROFIBUS DP interfaces (PROFIsafe)
  • The fail-safe I/O modules of ET 200M can be also centrally connected
  • The standard modules for non-safety applications can be operated both centrally and locally

Micro Memory Card required for CPU operation.

Note:

SIPLUS extreme products are based on Siemens Industry standard products. The contents listed here were taken from the respective standard products. SIPLUS extreme-specific information was added.

 

SIPLUS CPU 317F-2 DP

Order number

6AG1 317-6FF03-2AB0

6AG1 317-6FF03-2AY0

Order No. based on

6ES7 317-6FF03-0AB0

6ES7 317-6FF03-0AB0

Ambient temperature range

-25 ... +60 °C

Conformal coating

Coating of the printed circuit boards and the electronic components.

Technical data

The technical data of the standard product applies except for the environmental conditions.

Compliant with the standards for electronic equipment used on railway rolling stock (EN 50155, temperature T1, category 1).

No

Yes

Technical data

The technical data is identical to that of the based on modules.

Ambient conditions

 

Relative humidity

5 ... 100%, condensation allowed


Technical documentation on SIPLUS can be found here:
http://www.siemens.de/siplus-extreme

The CPU 317F-2 DP allows a fail-safe automation system to be implemented for plants with increased safety requirements, especially in manufacturing automation.

Distributed I/O stations containing fail-safe I/O modules can be connected through the two integrated PROFIBUS DP interfaces. The fail-safe I/O modules of ET 200M can also be installed in central and safety-related configurations.

The safety-oriented communication between the F-CPU and the fail-safe I/O modules is performed on the basis of the PROFIsafe profile.

A SIMATIC Micro Memory Card is required for operation of the CPU.

The CPU 317F-2 DP is equipped with the following:

  • Microprocessor;
    the processor achieves an execution time of approximately 25 ns per binary instruction and 160 µs per floating-point operation. The CPU 317F-2 DP is significantly superior regarding processing speed, particularly where word or double-word commands and 32 bit fixed-point commands are concerned
  • Memory;
    1.5 MB high-speed work memory for safety-relevant and standard program sections; increased memory space requirements must be expected (5 times larger) if safety-relevant program sections are implemented. SIMATIC Micro Memory Cards (8 MB max.) as load memory for the program also allow the project to be stored in the CPU (complete with symbols and comments) and can be used for data archiving and recipe management.
  • Flexible expansion
    up to 32 modules (four-tier configuration)
  • Combined MPI/DP interface
    The first MPI/DP integrated interface can establish as many as 32 connections simultaneously to S7-300/400 or connections to programming device, PC, OP. Among these connections, one is always reserved for programming devices and another for OPs. A simple network with up to 32 CPUs can be configured with the MPI interfaces and "global data communication".
  • The MPI interface can be reconfigured from an MPI to a DP interface. The DP interface can be used as a DP master or as a DP slave.
  • PROFIBUS DP interface;
    The second integrated interface of the CPU 317F-2 DP is a pure PROFIBUS DP interface that can be used as a DP master or as a DP slave. It allows a distributed automation configuration with high speeds and simple handling. From the user's point of view, the distributed I/Os are treated the same as central I/Os (identical configuration, addressing and programming).
    The PROFIBUS DP V1 standard is supported in full. This increases the scope of DP V1 standard slaves in terms of diagnostics and parameterization capability.
    Limitation: It is impossible to operate both interfaces simultaneously as slaves.

Distributed I/O stations containing fail-safe I/O modules can be connected through the two integrated PROFIBUS DP interfaces. The fail-safe I/O modules of ET 200M can also be installed in central and safety-related configurations. The fail-safe I/O modules of ET 200M can also be centrally implemented. Safety-related communication is performed over PROFIBUS DP with the PROFIsafe profile.

  • Password protection;
    a password concept protects the user program from unauthorized access.
  • Diagnostics buffer;
    the last 100 errors and interrupt events are saved in a buffer for diagnostics purposes.
  • Maintenance-free data backup;
    the CPU automatically saves all data in case of power failure so that the data are available again unchanged when the power returns

Configurable attributes

STEP 7 can be used to parameterize both S7 configurations and the properties and responses of the CPUs:

  • MPI multipoint interface;
    determination of node addresses.
  • Restart/cycle time behavior;
    stipulation of maximum cycle time and loading.
  • Clock bit memory;
    address setting
  • Protection level;
    definition of access rights to program and data.
  • System diagnostics;
    definition of the handling and scope of diagnostics messages.
  • Watchdog interrupts;
    setting of periodicity
  • Time-of-day interrupts;
    setting of date and time of start and periodicity
  • PROFIBUS DP master/slave interface;
    user-oriented address allocation for distributed I/O.

Indication and information functions

  • Status and error indications;
    LEDs indicate e.g. hardware, programming, time, I/O or bus errors, as well as operating states such as RUN, STOP and restart
  • Test functions;
    the PG can be used to display signal states in program execution, modify process variables independently of the user program, and read out the contents of stack memories.
  • Information functions;
    you can use the PG to obtain information about the storage capacity and operating mode of the CPU as well as the current loading of the main and load memories, current cycle times and diagnostic buffer contents in plain text.

Integrated communication functions

  • PG/OP communication
  • Global data communication
  • S7 basic communication
  • S7 communication (server only)

Sequential function chart

The CPU provides many extensive system functions for diagnostics, parameterization, synchronization, alerting, time measurement, etc.
Details can be found in the manual.

Communication

The safety-related communication and standard communication between the central controller and the distributed stations is conducted over PROFIBUS DP. The specially developed PROFIBUS profile PROFIsafe allows the transmission of user data associated with the safety function within the standard data telegram. Additional hardware components, e.g. special safety buses, are unnecessary. The required software is either integrated in the hardware components as an extension of the operating system, or must be loaded into the CPU as a certified software component.

Mode of operation

The safety functions of the F CPU are contained in the CPU's F program and in the fail-safe signal modules. The signal modules monitor the output and input signals by means of discrepancy analyses and test signal injections. The CPU monitors proper operation of the PLC by performing regular self-tests, instruction tests and logic and sequential program flow control. In addition, the I/O is checked by requesting signs of life. If an error is diagnosed on the system, the latter is moved to a safe state. An F runtime license is not required for operation of the CPU 317F-2 DP.

Programming

The CPU 317F-2 DP is programmed in the same manner as other SIMATIC S7 systems. The user program for non fail-safe plant sections is created with the proven programming tools such as STEP 7.

SIMATIC S7 Distributed Safety option package

The "S7 F Distributed Safety" option package is required to program the safety-relevant parts of the program. The package contains all the functions and blocks required to create the F program. The F program with the safety functions is linked in F-FBD or F-LAD or using special function blocks from the F library. Use of F-FBD or F-LAD simplifies plant planning and programming and, because of the uniform and cross-vendor presentation, the acceptance test too. Programmers can concentrate completely on configuration of the safety-relevant application without having to use additional tools.

 

6ES7 317-6FF04-0AB0

Product version

 

Hardware product version

01

Firmware version

V3.3

General information

 

associated programming package

STEP 7 V5.5 + SP1 or higher or STEP7 V5.2 + SP1 or higher with HSP 202 + Distributed Safety

Supply voltage

 

24 V DC

Yes

Input current

 

Current consumption (rated value)

870 mA

Current consumption (in no-load operation), typ.

120 mA

Inrush current, typ.

4 A

I²t

1 A²·s

Power losses

 

Power loss, typ.

4.5 W

Memory

 

Work memory

 

  • integrated

1 536 Kibyte

  • expandable

No

  • Size of retentive memory for retentive data blocks

256 Kibyte

Load memory

 

  • pluggable (MMC)

Yes

  • pluggable (MMC), max.

8 Mbyte

  • Data management on MMC (after last programming), min.

10 a

Backup

 

  • present

Yes; Guaranteed by MMC (maintenance-free)

  • without battery

Yes; Program and data

CPU-blocks

 

Number of blocks (total)

2 048; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.

DB

 

  • Number, max.

2 048; Number range: 1 to 16000

  • Size, max.

64 Kibyte

FB

 

  • Number, max.

2 048; Number range: 0 to 7999

  • Size, max.

64 Kibyte

FC

 

  • Number, max.

2 048; Number range: 0 to 7999

  • Size, max.

64 Kibyte

OB

 

  • Size, max.

64 Kibyte

Nesting depth

 

  • per priority class

16

  • additional within an error OB

4

CPU processing times

 

for bit operations, min.

0.025 µs

for word operations, min.

0.03 µs

for fixed point arithmetic, min.

0.04 µs

for floating point arithmetic, min.

0.16 µs

Counters, timers and their retentivity

 

S7 counter

 

  • Number

512

  • Retentivity

 

    • adjustable

Yes

    • lower limit

0

    • upper limit

511

    • preset

Z 0 to Z 7

  • Counting range

 

    • lower limit

0

    • upper limit

999

IEC counter

 

  • present

Yes

  • Type

SFB

  • Number

Unlimited (limited only by RAM capacity)

S7 times

 

  • Number

512

  • Retentivity

 

    • adjustable

Yes

    • lower limit

0

    • upper limit

511

    • preset

No retentivity

  • Time range

 

    • lower limit

10 ms

    • upper limit

9 990 s

IEC timer

 

  • present

Yes

  • Type

SFB

  • Number

Unlimited (limited only by RAM capacity)

Data areas and their retentivity

 

retentive data area, total

All, max. 256 KB

Flag

 

  • Number, max.

4 096 byte

  • Retentivity available

Yes; MB 0 to MB 4095

  • Retentivity preset

MB 0 to MB 15

  • Number of clock memories

8; 1 memory byte

Data blocks

 

  • Retentivity adjustable

Yes; via non-retain property on DB

  • Retentivity preset

Yes

Local data

 

  • per priority class, max.

32 768 byte; Max. 2048 bytes per block

Address area

 

I/O address area

 

  • Inputs

8 192 byte

  • Outputs

8 192 byte

  • of which, distributed

 

    • Inputs

8 192 byte

    • Outputs

8 192 byte

Process image

 

  • Inputs, adjustable

8 192 byte

  • Outputs, adjustable

8 192 byte

  • Inputs, default

1 024 byte

  • Outputs, default

1 024 byte

Subprocess images

 

  • Number of subprocess images, max.

1

Digital channels

 

  • Inputs

65 536

  • Outputs

65 536

  • Inputs, of which central

1 024

  • Outputs, of which central

1 024

Analog channels

 

  • Inputs

4 096

  • Outputs

4 096

  • Inputs, of which central

256

  • Outputs, of which central

256

Hardware configuration

 

Racks, max.

4

Modules per rack, max.

8

Expansion devices, max.

3

Number of DP masters

 

  • integrated

2

  • via CP

4

Number of operable FMs and CPs (recommended)

 

  • FM

8

  • CP, point-to-point

8

  • CP, LAN

10

Time of day

 

Clock

 

  • Hardware clock (real-time clock)

Yes

  • battery-backed and synchronizable

Yes

  • Deviation per day, max.

10 s; Typ.: 2 s

  • Backup time

6 wk; At 40 °C ambient temperature

  • Behavior of the clock following POWER-ON

Clock continues running after POWER OFF

  • Behavior of the clock following expiry of backup period

Clock continues to run with the time at which the power failure occurred

Operating hours counter

 

  • Number

4

  • Number/Number range

0 to 3

  • Range of values

0 to 2^31 hours (when using SFC 101)

  • Granularity

1 hour

  • retentive

Yes; Must be restarted at each restart

Clock synchronization

 

  • supported

Yes

  • to MPI, master

Yes

  • to MPI, slave

Yes

  • to DP, master

Yes; With DP slave only slave clock

  • to DP, slave

Yes

  • in AS, master

Yes

  • in AS, slave

Yes

  • on Ethernet via NTP

No

1st interface

 

Type of interface

Integrated RS 485 interface

Physics

RS 485

Isolated

Yes

Power supply to interface (15 to 30 V DC), max.

200 mA

Functionality

 

  • MPI

Yes

  • DP master

Yes

  • DP slave

Yes

  • Point-to-point connection

No

MPI

 

  • Services

 

    • PG/OP communication

Yes

    • Routing

Yes

    • Global data communication

Yes

    • S7 basic communication

Yes

    • S7 communication

Yes; Only server, configured on one side

    • S7 communication, as client

No; but via CP and loadable FB

    • S7 communication, as server

Yes

  • Transmission rate, max.

12 Mbit/s

DP master

 

  • Services

 

    • PG/OP communication

Yes

    • Global data communication

No

    • S7 basic communication

Yes; I blocks only

    • S7 communication

Yes; Only server, configured on one side

    • S7 communication, as client

No

    • S7 communication, as server

Yes

    • Equidistance mode support

Yes

    • Isochronous mode

No

    • SYNC/FREEZE

Yes

    • Activation/deactivation of DP slaves

Yes

    • Number of DP slaves that can be simultaneously activated/deactivated, max.

8

    • Direct data exchange (slave-to-slave communication)

Yes; As subscriber

    • DPV1

Yes

  • Transmission rate, max.

12 Mbit/s

  • Number of DP slaves, max.

124

  • Address area

 

    • Inputs, max.

8 Kibyte

    • Outputs, max.

8 Kibyte

  • User data per DP slave

 

    • Inputs, max.

244 byte

    • Outputs, max.

244 byte

DP slave

 

  • Services

 

    • PG/OP communication

Yes

    • Global data communication

No

    • S7 basic communication

No

    • S7 communication

Yes; Only server, configured on one side

    • S7 communication, as client

No

    • S7 communication, as server

Yes; Connection configured on one side only

    • Direct data exchange (slave-to-slave communication)

Yes

    • DPV1

No

  • Transmission rate, max.

12 Mbit/s

  • Automatic baud rate search

Yes; only with passive interface

  • Transfer memory

 

    • Inputs

244 byte

    • Outputs

244 byte

  • Address area, max.

32

  • User data per address area, max.

32 byte

2nd interface

 

Type of interface

Integrated RS 485 interface

Physics

RS 485

Isolated

Yes

Power supply to interface (15 to 30 V DC), max.

200 mA

Functionality

 

  • MPI

No

  • DP master

Yes

  • DP slave

Yes

  • Local Operating Network

No

DP master

 

  • Services

 

    • PG/OP communication

Yes

    • Global data communication

No

    • S7 basic communication

Yes; I blocks only

    • S7 communication

Yes; Only server, configured on one side

    • S7 communication, as client

No; but via CP and loadable FB

    • S7 communication, as server

Yes

    • Equidistance mode support

Yes

    • Isochronous mode

Yes; OB 61

    • SYNC/FREEZE

Yes

    • Activation/deactivation of DP slaves

Yes

    • Number of DP slaves that can be simultaneously activated/deactivated, max.

8

    • Direct data exchange (slave-to-slave communication)

Yes; As subscriber

    • DPV1

Yes

  • Transmission rate, max.

12 Mbit/s

  • Number of DP slaves, max.

124

  • Address area

 

    • Inputs, max.

8 192 byte

    • Outputs, max.

8 192 byte

  • User data per DP slave

 

    • Inputs, max.

244 byte

    • Outputs, max.

244 byte

DP slave

 

  • Services

 

    • PG/OP communication

Yes

    • Global data communication

No

    • S7 basic communication

No

    • S7 communication

Yes; Only server, configured on one side

    • S7 communication, as client

No; but via CP and loadable FB

    • S7 communication, as server

Yes

    • Direct data exchange (slave-to-slave communication)

Yes

    • DPV1

No

  • GSD file

The latest GSD file is available on the Internet (http://www.siemens.com/profibus-gsd)

  • Transmission rate, max.

12 Mbit/s

  • Automatic baud rate search

Yes; only with passive interface

  • Transfer memory

 

    • Inputs

244 byte

    • Outputs

244 byte

  • Address area, max.

32

  • User data per address area, max.

32 byte

Communication functions

 

PG/OP communication

Yes

Data record routing

Yes

Global data communication

 

  • supported

Yes

  • Number of GD loops, max.

8

  • Number of GD packets, max.

8

  • Number of GD packets, transmitter, max.

8

  • Number of GD packets, receiver, max.

8

  • Size of GD packets, max.

22 byte

  • Size of GD packet (of which consistent), max.

22 byte

S7 basic communication

 

  • supported

Yes

  • User data per job, max.

76 byte

  • User data per job (of which consistent), max.

76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server)

S7 communication

 

  • supported

Yes

  • as server

Yes

  • as client

Yes; Via CP and loadable FB

  • User data per job, max.

See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication)

S5-compatible communication

 

  • supported

Yes; via CP and loadable FC

Number of connections

 

  • usable for routing

X1 as a MPI, max. 10; X1 as DP Master max. 24; X1 as DP Slave (active) max. 14; X2 as DP Master max. 24; X2 as DP Slave (active) max. 14

S7 message functions

 

Number of login stations for message functions, max.

32; Depending on the configured connections for PG/OP and S7 basic communication

Process diagnostic messages

Yes

simultaneously active Alarm-S blocks, max.

300

Test commissioning functions

 

Status/control

 

  • Status/control variable

Yes

  • Variables

Inputs, outputs, memory bits, DB, times, counters

  • Number of variables, max.

30

  • of which status variables, max.

30

  • of which control variables, max.

14

Forcing

 

  • Forcing

Yes

  • Force, variables

Inputs, outputs

  • Number of variables, max.

10

Status block

Yes; Up to 2 simultaneously

Single step

Yes

Number of breakpoints

4

Diagnostic buffer

 

  • present

Yes

  • Number of entries, max.

500

    • adjustable

No

    • Of which powerfail-proof

100; Only the last 100 entries are retained

  • Number of entries readable in RUN, max.

499

    • adjustable

Yes; From 10 to 499

    • preset

10

Ambient conditions

 

Operating temperature

 

  • Min.

0 °C

  • max.

60 °C

Configuration

 

Configuration software

 

  • STEP 7

Yes; STEP7 as of V5.5 + SP1 or STEP 7 V5.2 + SP1 or higher with HSP 202

  • STEP 7 Lite

No

programming

 

  • Programming language

 

    • LAD

Yes

    • FBD

Yes

    • STL

Yes

    • SCL

Yes

    • CFC

Yes

    • GRAPH

Yes

    • HiGraph®

Yes

  • Command set

see instruction list

  • Nesting levels

8

Know-how protection

 

  • User program protection/password protection

Yes

  • Block encryption

Yes; With S7 block Privacy

Dimensions

 

Width

40 mm

Height

125 mm

Depth

130 mm

Weight

 

Weight, approx.

360 g


Код Заказной номер Описание Вес (кг) Заказать
109050 6AG1305-1AA00-2AA0 siplus upmiter 4a, рабочая температура -25... +60 градусов цельсия, (s7-300-style) 1.2 Заказать
109067 6AG1317-6FF03-2AB0 siplus s7-300 модуль цпу cpu317f-2dp (1mb), темп. диапазон от -25... +60 град. цельсия, на базе модуля 6es7317-6ff03-0ab0 0.529 Заказать
109068 6AG1317-6FF03-2AY0 siplus s7-300, модуль цпу cpu317f-2dp, расширенный диапазон рабочих температур -25... + 60 градусов цельсия согласно en50155, на основе модуля 6es7317-6ff00-0ab0 0.529 Заказать
110756 6ES7391-1AA00-0AA0 simatic s7-300, запасной съемный соединитель для подключения цепей питания =24в к центральным процессорам s7-300 compact и модулю fm352-5, упаковка из 10 штук 0.061 Заказать
110780 6ES7398-8EA00-8AA0 simatic s7-300/-400, руководство по связи s7-300/-400, немецкий язык 0.585 Заказать
110781 6ES7398-8EA00-8BA0 simatic s7-300/-400, руководство по связи s7-300/-400, английский язык 0.568 Заказать
110782 6ES7398-8FA10-8AA0 simatic s7-300 compact, руководство по конфигурированию, технические характеристики центральных процессоров, технические характеристики модулей, список инструкций, немецкий язык 5 Заказать
110783 6ES7398-8FA10-8BA0 simatic s7-300 compact, руководство по конфигурированию, технические характеристики центральных процессоров, технические характеристики модулей, список инструкций, английский язык 5 Заказать
63144 6ES7833-1FC02-0YA5 simatic s7, f средство разработки распределенных систем повышенной безопасности distributed safety v5.4, плавающая лицензия для 1 пользователя, инженерное прогр. обеспечение, прогр. обесп. и документация на cd, class a, 3 языка (нем., англ.,франц.), работа под step7 v5.3 sp3 0.257 Заказать
63145 6ES7833-1FC02-0YE5 simatic s7, f средство программирования distributed safety v5.4, пакет обновления от версии 5.x до версии 5.4, плавающая лицензия для 1 пользователя, инженерное прогр. обеспечение, прогр. обесп. и документация на cd, class a, 3 языка (нем., англ.,франц.), работа под step7 v5.3 sp3 0.257 Заказать
63182 6ES7901-0BF00-0AA0 simatic s7, mpi-кабель для подключения simatic s7 к программатору через mpi, длина 5m 0.274 Заказать
111168 6ES7912-0AA00-0AA0 simatic s7, пластиковые метки маркироки номеров модулей в монтажных стойках s7-300/ s7-400/ et 200m/ c7 0.006 Заказать
111241 6ES7953-8LF20-0AA0 simatic s7, микрокарта памяти mmc для s7-300/c7/et 200, 3.3 в nflash, 64 кбайт 0.012 Заказать
111242 6ES7953-8LG20-0AA0 simatic s7, микрокарта памяти mmc для s7-300/c7/et 200, 3.3 в nflash, 128 кбайт 0.014 Заказать
111243 6ES7953-8LJ30-0AA0 simatic s7, micro memory card f. s7-300/c7/et 200, 3.3 v nflash, 512 kbytes 0.012 Заказать
111244 6ES7953-8LL20-0AA0 simatic s7, микрокарта памяти mmc для s7-300/c7/et 200, 3.3 в nflash, 2 мбайт 0.012 Заказать
111245 6ES7953-8LM20-0AA0 simatic s7, микрокарта памяти mmc для s7-300/c7/et 200, 3.3 в nflash, 4 мбайт 0.012 Заказать
111246 6ES7953-8LP20-0AA0 simatic s7, микрокарта памяти mmc для s7-300/c7/et 200, 3.3 в nflash, 8 мбайт 0.013 Заказать
111255 6ES7972-0AA02-0XA0 simatic dp, rs485-повторитель для подключения шинной системы profibus/mpi bus systems с макс. 31 узлом; макс. 12 мбит/с, степень защиты ip20, улучшенные пользовательские свойства 0.289 Заказать
63269 6ES7972-0BA12-0XA0 simatic dp, соединитель для подключения к profibus, до 12 мбит/с, отвод кабеля под углом 90 градусов, 15.8 x 54 x 34 mm, с встроенным терминальным резистором, с функциями разделения, без гнезда для подключения программатора 0.049 Заказать
111257 6ES7972-0BA52-0XA0 simatic dp, шинный оединитель для подключения к сетям profibus до 12 мбит/с, отвод кабеля под углом 90 градусов, 15,8 x 59 x 35,6 mm (шxвxг), ipcd, технология fast connect, без разъёма для подключения программатора 0.044 Заказать
111258 6ES7972-0BA52-0XB0 simatic dp,bus connector for profibus up to 12 mbit/s 90 degree angle outgoing cable, 15,8 x 59 x 35,6 mm (wxhxd), ipcd techology fast connect, without pg socket 100 pieces per packaging unit 4.5 Заказать
111260 6ES7972-0BB12-0XA0 simatic dp, соединитель для подключения к profibus, до 12 мбит/с, отвод кабеля под углом 90 градусов, 15.8 x 54 x 34 mm, с встроенным терминальным резистором, с функциями разделения, с гнездом для подключения программатора 0.056 Заказать
63271 6ES7972-0BB52-0XA0 simatic dp, шинный оединитель для подключения к сетям profibus до 12 мбит/с, отвод кабеля под углом 90 градусов, 15,8 x 59 x 35,6 mm (шxвxг), ipcd, технология fast connect, с разъёмом для подключения программатора 0.049 Заказать
111262 6ES7972-0BB52-0XB0 simatic dp,bus connector for profibus up to 12 mbit/s 90 degree angle outgoing cable, 15,8 x 59 x 35,6 mm (wxhxd), ipcd techology fast connect, with pg socket 100 pieces per packaging unit 5 Заказать
63274 6ES7972-0CB20-0XA0 simatic s7, pc usb адаптер для подкл. simatic s7-200/s7-300/ s7-400/ c7 к компьютеру/ программатору через usb интерфейс: pc usb адаптер, cd с набором драйверов и док., usb кабель длиной 5 м, mpi кабель длиной 0.3 м. работа под упр. win 2000/xp 0.526 Заказать
63287 6ES7998-8XC01-8YE0 коллекция руководств simatic на cd-rom. pdf-формат, анг/ нем/ фр/ исп/ ит. язык. все руководства по s7-200/ -300/ -400/ -c7/ -logo!; simatic dp/ -pc/ -pg; step7, инстр. средствам проектирования, прогр. обеспечению runtime, simatic pcs7/ hmi/ net 0.2 Заказать
63288 6ES7998-8XC01-8YE2 коллекция руководств simatic на cd-rom, 5-языковая поддержка (без русского), служба обновления в течение 1 года 0.4 Заказать
114346 6GK1500-0EA02 simatic net, pb шинный соединитель с осевым отводом кабеля для пром. пк, simatic op, olm; скорость передачи 12 мбит/с, оконечный резистор с функциями разделения 0.104 Заказать
116945 6XV1830-0EH10 simatic net, стандартный экранированный profibus кабель для быстрого монтажа (fc), 2-жильный, поставка по метражу отрезками длиной 20 ... 1000 m 0.081 Заказать
;