Блоки питания SIPLUS производства Siemens

Блоки питания SIPLUS
  • Power supplies for SIPLUS S7-400
  • For conversion of AC or DC line voltages to the 5 V DC and 24 V DC operating voltages required
  • 4 A, 10 A and 20 A output currents

Note:

SIPLUS extreme products are based on Siemens Industry standard products. The contents listed here were taken from the respective standard products. SIPLUS extreme-specific information was added.

SIPLUS S7-400 PS

 

 

Order No.

6AG1 405-0KA02-2AA0

6AG1 407-0KR02-4AA0

Order No. based on

6ES7 405-0KA02-0AA0

6ES7 407-0KR02-0AA0

Ambient temperature range

-25 ... +70 °C

-0 ... +60 °C

Conformal coating

Coating of the printed circuit boards and the electronic components

Technical data

The technical data of the standard product applies, except for the environmental conditions

Environmental conditions

Relative humidity

5 ... 100 %
Condensation permissible

Biologically active substances

Conformity with EN 60721‑3‑3, Class 3B2 mold and fungal spores (except fauna)

Chemically active substances

Conformity with EN 60721‑3‑3, Class 3C4 incl. salt mist and ISA–S71.04 severity level G1; G2; G3; GX 1)2)

Mechanically active substances

Conformity with EN 60721‑3‑3, Class 3S4 including sand, dust 2)

Air pressure (depending on the highest positive temperature range specified)

1080 ... 795 hPa (-1000 ... +2000 m)
see ambient temperature range

795 ... 658 hPa (+2000 ... +3500 m)
derating 10 K

658 ... 540 hPa (+3500 ... +5000 m)
derating 20 K


1) ISA-S71.04 severity level GX: Long-term load: SO2 < 4.8 ppm; H2S < 9.9 ppm; Cl < 0.2 ppm; HCl < 0.66 ppm; HF < 0.12 ppm; NH < 49 ppm; O3 < 0.1 ppm; NOX < 5.2 ppm
Limit value (max. 30 min/d): SO2 < 14.8 ppm; H2S < 49.7 ppm; Cl < 1.0 ppm; HCl < 3.3 ppm; HF < 2.4 ppm; NH < 247 ppm; O3 < 1.0 ppm; NOX < 10.4 ppm

2) The supplied plug covers must remain in place over the unused interface when operated in atmospheres containing corrosive gases!

For further technical documentation on SIPLUS, see:
http://www.siemens.com/siplus-extreme

The power supplies supply the S7-400 modules with their 5 V DC and 24 V DC operating voltages via the backplane bus.

Power supplies are available for AC line voltages of 85 to 264 V and for DC voltages of 19.2 to 300 V.

One power supply module is required per rack.
Exception:
With interfaces with current transfer, the power supply module in the central controller also supplies all modules in the expansion units.

The load voltage for supplying sensors and actuators must be made available separately.

There are also power supplies to make both the standard system and the H system fail-safe (redundant power supplies).

The power supply modules are inserted at the far left in the rack (starting from slot 1). Depending on the version, they occupy slots 1 to 3. The modules are enclosed and are cooled via natural convection.

The front of the module contains:

  • LED displays:
    LEDS indicate internal faults, correct output voltages 5 V DC, 24 V DC, and correct back-up battery voltage.
  • Pushbutton for fault acknowledgment.
  • On/off switch for output voltages.
  • Battery compartment for back-up battery (batteries).
  • Switch for battery monitoring.
  • Supply voltage selector switch (not for wide-range power supplies).
  • Power supply connection.

The back-up battery is optional and must be ordered in addition. For power supplies at and above 10 A, two back-up batteries are recommended.

 

6ES7 405-0DA02-0AA0

6ES7 405-0KA02-0AA0

6ES7 405-0KR02-0AA0

6ES7 405-0RA02-0AA0

 

PS405, 24 VDC, 5 VDC/4 A

PS405, 24/48/60 VDC, 5 VDC/10 A

PS405,24/48/60 VDC,5 VDC/10 A,RED

PS405, 24/48/60 VDC, 5 VDC/20 A

Supply voltage

 

 

 

 

Rated value, 24 V DC

Yes

Yes

Yes

Yes

Rated value, 48 V DC

Yes

Yes

Yes

Yes

Rated value, 60 V DC

Yes

Yes

Yes

Yes

permissible range, lower limit (DC)

19.2 V; Dynamic 18.5 V

19.2 V; Dynamic 18.5 V

19.2 V; Dynamic 18.5 V

19.2 V; Dynamic 18.5 V

permissible range, upper limit (DC)

72 V; dynamic 75.5 V

72 V; dynamic 75.5 V

72 V; dynamic 75.5 V

72 V; dynamic 75.5 V

Mains buffering

 

 

 

 

  • Mains/voltage failure stored energy time

20 ms

20 ms

20 ms

20 ms

  • Mains buffering according to NAMUR recommendation

Yes

Yes

Yes

Yes

Input current

 

 

 

 

Rated value at 24 V DC

2 A

4 A

4 A

7 A

Rated value at 48 V DC

1 000 mA

2 A

2 A

3.2 A

Rated value at 60 V DC

800 mA

1.6 A

1.6 A

2.5 A

Inrush current, max.

18 A; Full width at half maximum 20 ms

18 A; Full width at half maximum 20 ms

18 A; Full width at half maximum 20 ms

56 A; Full width at half maximum 1.5 ms

Output voltage

 

 

 

 

Rated value, 5 V DC

Yes

Yes

Yes

Yes

Rated value, 24 V DC

Yes

Yes

Yes

Yes

Output current

 

 

 

 

for backplane bus (5 V DC), max.

4 A; no base load required

10 A; no base load required

10 A; no base load required

20 A; no base load required

for backplane bus (24 V DC), max.

0.5 A; idling-proof

1 A; idling-proof

1 A; idling-proof

1 A; idling-proof

Short-circuit protection

Yes

Yes

Yes

Yes

Power

 

 

 

 

Power consumption, typ.

48 W

95 W

95 W

168 W

Power losses

 

 

 

 

Power loss, typ.

16 W

20 W

20 W

44 W

Backup battery

 

 

 

 

Backup battery

 

 

 

 

  • Backup battery (optional)

Yes; 1 x lithium AA; 3.6 V/2.3 Ah

Yes; 2 x lithium AA; 3.6 V/2.3 Ah

Yes; 2 x lithium AA; 3.6 V/2.3 Ah

Yes; 2 x lithium AA; 3.6 V/2.3 Ah

Galvanic isolation

 

 

 

 

primary/secondary

Yes

Yes

Yes

Yes

Degree and class of protection

 

 

 

 

Protection class

1; with protective conductor

1; with protective conductor

1; with protective conductor

1; with protective conductor

Standards, approvals, certificates

 

 

 

 

FM approval

Yes; Ta: 0 °C to 60 °C T4

Yes; Ta: 0 °C to 60 °C T4

Yes; Ta: 0 °C to 60 °C T4

Yes; Ta: 0 °C to 60 °C T4

Connection method

 

 

 

 

Connecting cables/cross sections

3 x 1.5 mm2, solid or stranded wire with end sleeve, external diameter 3 to 9 mm

3 x 1.5 mm2, solid or stranded wire with end sleeve, external diameter 3 to 9 mm

3 x 1.5 mm2, solid or stranded wire with end sleeve, external diameter 3 to 9 mm

3 x 1.5 mm2, solid or stranded wire with end sleeve, external diameter 3 to 9 mm

Dimensions

 

 

 

 

Width

25 mm

50 mm

50 mm

50 mm

Height

290 mm

290 mm

290 mm

290 mm

Depth

217 mm

217 mm

217 mm

217 mm

Required slots

1

2

2

2

Weight

 

 

 

 

Weight, approx.

760 g

1 200 g

1 200 g

1 300 g


 

6ES7 407-0DA02-0AA0

6ES7 407-0KA02-0AA0

6ES7 407-0KR02-0AA0

6ES7 407-0RA02-0AA0

Supply voltage

 

 

 

 

Rated value, 110 V DC

Yes; Rated value 120 V DC

Yes; Rated value 120 V DC

Yes; Rated value 120 V DC

Yes; Rated value 120 V DC

Rated value, 230 V DC

Yes

Yes

Yes

Yes

permissible range, lower limit (DC)

88 V

88 V

88 V

88 V

permissible range, upper limit (DC)

300 V

300 V

300 V

300 V

Rated value, 120 V AC

Yes

Yes

Yes

Yes

Rated value, 230 V AC

Yes

Yes

Yes

Yes

Line frequency

 

 

 

 

  • Rated value 50 Hz

Yes

Yes

Yes

Yes

  • Rated value 60 Hz

Yes

Yes

Yes

Yes

  • permissible range, lower limit

47 Hz

47 Hz

47 Hz

47 Hz

  • permissible range, upper limit

63 Hz

63 Hz

63 Hz

63 Hz

Mains buffering

 

 

 

 

  • Mains/voltage failure stored energy time

20 ms

20 ms

20 ms

20 ms

  • Mains buffering according to NAMUR recommendation

Yes

Yes

Yes

Yes

Input current

 

 

 

 

Rated value at 110 V DC

350 mA; at 120 V DC

1 A; at 120 V DC

1 A; at 120 V DC

1.4 A; at 120 V DC

Rated value at 230 V DC

190 mA

0.5 A

0.5 A

0.7 A

Rated value at 120 V AC

0.42 A

0.9 A

0.9 A

1.4 A

Rated value at 230 V AC

0.22 A

0.5 A

0.5 A

0.7 A

Inrush current, max.

8.25 A; Full width at half maximum 5 ms

63 A; Full width at half maximum 1 ms

63 A; Full width at half maximum 1 ms

88 A; Full width at half maximum 1.1 ms

Output voltage

 

 

 

 

Rated value, 5 V DC

Yes

Yes

Yes

Yes

Rated value, 24 V DC

Yes

Yes

Yes

Yes

Output current

 

 

 

 

for backplane bus (5 V DC), max.

4 A; no base load required

10 A; no base load required

10 A; no base load required

20 A; no base load required

for backplane bus (24 V DC), max.

0.5 A; idling-proof

1 A; idling-proof

1 A; idling-proof

1 A; idling-proof

Short-circuit protection

Yes

Yes

Yes

Yes

Power

 

 

 

 

Power consumption, typ.

52 W

95 W

95 W

158 W

Power losses

 

 

 

 

Power loss, typ.

20 W

20 W

20 W

35 W

Backup battery

 

 

 

 

Backup battery

 

 

 

 

  • Backup battery (optional)

Yes; 1 x lithium AA; 3.6 V/2.3 Ah

Yes; 2 x lithium AA; 3.6 V/2.3 Ah

Yes; 2 x lithium AA; 3.6 V/2.3 Ah

Yes; 2 x lithium AA; 3.6 V/2.3 Ah

Galvanic isolation

 

 

 

 

primary/secondary

Yes

Yes

Yes

Yes

EMC

 

 

 

 

Compliance with line harmonic distortion limits

 

 

 

 

  • Observance of line harmonic distortion acc. to IEC 61000-3-2, IEC 61000-3-3

Yes

Yes

Yes

Yes

Degree and class of protection

 

 

 

 

Protection class

1; with protective conductor

1; with protective conductor

1; with protective conductor

1; with protective conductor

Standards, approvals, certificates

 

 

 

 

FM approval

Yes; Ta: 0 °C to 60 °C T4

Yes; Ta: 0 °C to 60 °C T4

Yes; Ta: 0 °C to 60 °C T4

Yes; Ta: 0 °C to 60 °C T4

Connection method

 

 

 

 

Connecting cables/cross sections

3 x 1.5 mm2, solid or stranded wire with end sleeve, external diameter 3 to 9 mm

3 x 1.5 mm2, solid or stranded wire with end sleeve, external diameter 3 to 9 mm

3 x 1.5 mm2, solid or stranded wire with end sleeve, external diameter 3 to 9 mm

3 x 1.5 mm2, solid or stranded wire with end sleeve, external diameter 3 to 9 mm

Dimensions

 

 

 

 

Width

25 mm

50 mm

50 mm

50 mm

Height

290 mm

290 mm

290 mm

290 mm

Depth

217 mm

217 mm

217 mm

217 mm

Required slots

1

2

2

2

Weight

 

 

 

 

Weight, approx.

760 g

1 200 g

1 200 g

1 300 g


Brochures

Information material for downloading can be found in the Internet:

http://www.siemens.com/simatic/printmaterial

Код Заказной номер Описание Вес (кг) Заказать
60658 6AG1407-0KR02-4AA0 siplus резервируемый блок питания ps407 10a, для тяжёлых рабочих условий, на основе блока 6es7407-0kr02-0aa0 1.455 Заказать
62367 6ES7490-0AA00-0AA0 simatic s7-400, запасной съемный соединитель подключения цепей питания к ps405 4a/10a/20a 0.049 Заказать
110825 6ES7490-0AB00-0AA0 simatic s7-400, запасной съемный соединитель подключения цепей питания к ps407 4a/10a/20a 0.051 Заказать
63265 6ES7971-0BA00 simatic s7-400, буферная батарея 3.6в/1.9ачас, для ps 405 4a/10a/20a и ps 407 4a/10a/20a. для 4 а блока питания необходима одна, для 10- и 20 а блоков питания - две буферные батареи 0.027 Заказать
;