19" rack unit производства Siemens

19" rack unit

General

 

Measurement ranges

4, internally and externally switchable; automatic measuring range switchover also possible

Smallest possible span (relating to sample gas pressure 1 000 hPa absolute, 0.5 l/min sample gas flow, and 25 °C ambient temperature)

0 ... 10 vpm O2

Largest possible measuring span

0 ... 100 %

Operating position

Front wall vertical

Conformity

CE mark in accordance with EN 50081-1, EN 50082-2 and RoHS

Design, enclosure

 

Degree of protection

IP20 according to EN 60529

Weight

Approx. 11 kg

Electrical characteristics

 

EMC (Electromagnetic Compatibility)

In accordance with standard requirements of NAMUR NE21 (08/98) and EN 61326

Electrical safety

In accordance with EN 61010-1, overvoltage category II

Power supply

100 ... 120 V AC (nominal range of use 90 ... 132 V), 48 ... 63 Hz or

200 ... 240 V AC (nominal range of use 180 ... 264 V), 48 ... 63 Hz

Power consumption

Approx. 37 VA

Fuse values

100 ... 120 V: 1.0T/250

200 ... 240 V: 0.63T/250

Gas inlet conditions

 

Sample gas flow

 

  • through the sensor

7.5 l/h

  • Overall consumption

15 ... 30 l/h

Permissible sample gas pressure

 

  • without internal pressure regulator

2 000 hPa (abs.)

  • with internal pressure regulator

2 000 ... 6 000 hPa (abs.)

Sample gas temperature

Min. 0 ... max. 50 °C, but above the dew point

Sample gas humidity

< 1% relative humidity

Dynamic response

 

Warm-up period

At room temperature < 30 min (the technical specification will be met after 2 hours)

Damping (electrical time constant)

0 ... 100 s, parameterizable

Dead time (high-pressure version) (purging time of the gas path in the unit at 125 ml/min)

10 ... 30 s

Dead time (low-pressure version without pump)

< 5 s

Dead time (low-pressure version with pump)

< 10 s

Time for device-internal signal processing

< 1 s

Pressure correction range

 

Pressure sensor internal

800 ... 1 100 hPa (abs.)

Measuring response (referred to sample gas pressure 1 013 hPa absolute, sample gas flow 7.5 l/min, and ambient temperature 25 °C)

Output signal fluctuation

< ± 1% of the smallest possible measuring range according to rating plate, with electronic damping constant of 1 s

Zero point drift

< ± 1 % of the current span/month

Measured-value drift

< ± 1 % of the current span/month

Repeatability

< 3% of the current measuring span

Detection limit

1 % of current measuring range,

< 0.1 vpm in measuring range

0 ... 10 vpm

Linearity error

< 2% of the current measuring span

Influencing variables (relating to sample gas pressure 1 013 hPa absolute, 7.5 l/min sample gas flow and 25 °C ambient temperature)

Ambient temperature

< 2%/10 K referred to current measuring span

Sample gas pressure only possible if the sample gas can flow out into the ambient air

  • When pressure compensation has been switched off: < 1 % of current span/1 % pressure change
  • When pressure compensation has been switched on: < 0.2 % of current span/1 % pressure change

Residual gases, deviation from zero point

 

  • Catalytically active sensor (CAZ)

Only gases with non-combustible residual gas components can be introduced

  • Catalytically inactive sensor (CIZ)

Residual gas concentration of 10 vpm H2; CO and CH4 have a lower cross-interference; higher HCs are negligible

Sample gas flow

< 2 % of the smallest possible span with a change in flow of 10 ml/min

Power supply

< 0.1 % of the current measuring range with rated voltage ± 10 %

Electrical inputs and outputs

 

Analog output

0/2/4 ... 20 mA, 4 … 20 mA (NAMUR), isolated; max. load 750 Ω

Relay outputs

6, with changeover contacts, freely parameterizable, e.g. for measuring range identification; load: 24 V AC/DC/1 A, isolated

Analog inputs

2, dimensioned for 0/2/4 … 20 mA for external pressure sensor and correction of influence of residual gas (correction of cross-interference)

Binary inputs

6, designed for 24 V, isolated, freely parameterizable, e.g. for measurement range switchover

Serial interface

RS 485

Options

AUTOCAL function each with 8 additional binary inputs and relay outputs, also with PROFIBUS PA or PROFIBUS DP

Climatic conditions

 

Permissible ambient temperature

-40 ... +70 °C during storage and transportation, 5 … 45 °C during operation

Permissible humidity

< 90% relative humidity as annual average, during storage and transportation (must not fall below dew point)


OXYMAT 64, 19" rack unit, size in mm

Pin assignment (electrical connections)

OXYMAT 64, 19" rack unit, pin assignment

OXYMAT 64, 19" rack unit, pin assignment of the AUTOCAL plate and PROFIBUS plug

Gas connections and pin assignment

OXYMAT 64, 19" rack unit, gas connections and electrical connections

Код Заказной номер Описание Вес (кг) Заказать
70844 7MB2041-.....-.... газовый анализатор кислорода малых концентрация, 19" шкафное исполнение 14.5 Заказать
77977 A5E00057307 autocal board with 8 binary- inputs/outputs and profibus pa 0.5 Заказать
124413 A5E00057312 autocal board with mit 8 binary inputs and 8 binary outputs and profibus dp 0.5 Заказать
78169 A5E00852382 usb-rs485 converter 1 Заказать
124619 A5E00852383 rs 485 / ethernet-converter 1 Заказать
126071 C79451-A3480-D511 additional electronics modul 0.243 Заказать
126081 C79451-Z1589-U1 interface converter rs 485 / rs 232 (retrofit set) 0.716 Заказать
;