The SITRANS P250 transmitter measures the differential pressure of liquids and gases.
The SITRANS P250 transmitter for differential pressure is primarily used in the following industries:
SITRANS P250 differential pressure transmitter | |
---|---|
Application | |
Differential pressure transmitter | Liquids and neutral gases |
Mode of operation | |
Measuring principle | Piezo-resistive measuring cell (ceramic diaphragm) |
Input | |
Measured variable | Differential pressure |
Measuring range | 0 ... 0.1 to 0 ... 25 bar (0 ... 1.45 to 0 ... 363 psi) |
Operating pressure | ≤ 25 bar at a differential pressure range > 6 bar ≤ 50 bar at a differential pressure range > 10 bar |
Burst pressure | 1.5 x operating pressure |
Output | |
Output signal | |
| 4 ... 20 mA |
| 0 ... 5 V DC and 0 ... 10 V DC |
Load | |
| > 10 kΩ |
| ≤ (UH - 11 V) / 0.02 A |
Measuring accuracy | |
Error in measurement at limit setting incl. hysteresis and reproducibility | ≤ 1 % of typical full-scale value, see "Measuring range" table |
Long-term stability acc. to IEC 60770 | ≤ 0.5 % of full-scale value/year |
Influence of ambient temperature | |
| ≤ 0.6 % / 10 K of full-scale value (≤ 1.2 % / 10 K for measuring cell 0 ... 0.1 bar (1.45 psi)) |
| ≤ 0.22 % / 10 K of full-scale value (≤ 0.37 % / 10 K for measuring cell 0 ... 0.1 bar (1.45 psi)) |
Dynamic behavior | Suitable for static and dynamic measurements |
Step response time T99 | < 5 ms |
Load variation | < 50 Hz |
Rated conditions | |
---|---|
Ambient conditions | |
| - 15 ...+ 85 °C (5 ... 185 °F) |
| - 15 ...+ 85 °C (5 ... 185 °F) |
| - 40 ...+ 85 °C (-40 ... +185 °F) |
Degree of protection to IEC 60529 | IP65 |
Mounting position | Any |
Mounting | Mounting bracket, included in delivery |
Design | |
Weight | Approx. 430 g (approx. 0.95 lb) |
Enclosure material | Stainless steel 1.4305/AISI 303 |
Electrical connection |
|
Process connection |
|
Wetted parts materials | |
| Stainless steel 1.4305/AISI 303, CuZn nickel-plated |
| Ceramic Al2O3 (96 %) |
| FPM (standard), EPDM, NBR, MVQ, CR |
Power supply UH | |
Terminal voltage on pressure transmitter | |
| 11 ... 33 V DC |
| 11 ... 33 V DC/ 24 V AC ±15 % |
| 18 ... 33 V DC/ 24 V AC ±15 % |
Current consumption at nominal pressure | |
| < 20 mA |
| < 5 mA |
Protection against polarity reversal | Protected against short-circuit and polarity reversal. Each connection against the other with max. supply voltage. |
Certificates and approvals | |
Approval | CE conformity |
Measuring range | Max. permissible operating pressure | Burst pressure | Max. permissible operating pressure | Accuracy | |
---|---|---|---|---|---|
[bar] | [inH2O] | ||||
0 ... 0,1 | 0 ... 40.18 | 25 bar | 37.5 bar | 0.6 bar | ≤ 1,0 % |
0 ... 0,2 | 0 ... 80.37 | 25 bar | 37.5 bar | 0.6 bar | ≤ 0,8 % |
0 ... 0,25 | 0 ... 100.46 | 25 bar | 37.5 bar | 0.6 bar | ≤ 0,5 % |
0 ... 0,3 | 0 ... 120.56 | 25 bar | 37.5 bar | 0.6 bar | ≤ 0,5 % |
0 ... 0,4 | 0 ... 160.74 | 25 bar | 37.5 bar | 1.2 bar | ≤ 0,8 % |
0 ... 0,5 | 0 ... 200.9 | 25 bar | 37.5 bar | 1.2 bar | ≤ 0,5 % |
0 ... 0,6 | 0 ... 241.0 | 25 bar | 37.5 bar | 1.2 bar | ≤ 0,5 % |
0 ... 1,0 | 0 ... 402.0 | 25 bar | 37.5 bar | 2 bar | ≤ 0,5 % |
0 ... 1,6 | 0 ... 643.0 | 25 bar | 37.5 bar | 3.2 bar | ≤ 0,5 % |
0 ... 2,5 | 0 ... 1005 | 25 bar | 37.5 bar | 5 bar | ≤ 0,5 % |
0 ... 4 | 0 ... 1607 | 25 bar | 37.5 bar | 8 bar | ≤ 0,5 % |
0 ... 6 | 0 ... 2411 | 25 bar | 37.5 bar | 12 bar | ≤ 0,5 % |
0 ... 10 | 0 ... 4019 | 50 bar | 75 bar | 20 bar | ≤ 0,5 % |
0 ... 16 | 0 ... 6430 | 50 bar | 75 bar | 32 bar | ≤ 0,5 % |
0 ... 25 | 0 ... 10046 | 50 bar | 75 bar | 50 bar | ≤ 0,5 % |
Main components:
The pressure transmitter measures the differential pressure of liquids and gases.
SITRANS P250 pressure transmitter, function diagram
The piezo-resistive measuring cell (ceramic membrane) has a Wheatstone bridge circuit, on which the operating pressure P1 and P2 of the media acts at both ends.
The voltage output from the measuring cell is converted by an amplifier into an output current of 4 to 20 mA or an output voltage of 0 to 5 or 10 V DC.
The output current and voltage are linearly proportional to the input pressure.
SITRANS P250 differential pressure transmitter with socket outlet to EN 175301-803-A, dimensions in mm (inch)
SITRANS P250 differential pressure transmitter with round connector to EN 60130-9, dimensions in mm (inch)
SITRANS P250 differential pressure transmitter with cable, dimensions in mm (inch)
Process connections | ∅ | Width across flats | L | X | ||||
---|---|---|---|---|---|---|---|---|
[mm] | [inch] | [mm] | [inch] | [mm] | [inch] | |||
Hose connection for hose (CuZn nickel-plated) | 4 | 0.16 | a = 10 | 20 | 0.79 | 61 | 2.40 | |
6 | 0.24 | a = 10 | 25 | 0.99 | 66 | 2.60 | ||
Pipe union with screw-in nipple for outer pipe (CuZn nickel-plated) | 6 | 0.24 | a = 10 b = 12 | 24 | 0.95 | 65 | 2.56 | |
8 | 0.32 | a = 12 b = 14 | 25 | 0.99 | 66 | 2.60 | ||
Pipe union with screw-in nipple for outer pipe (stainless steel 1.4305/AISI 303) | 6 | 0.24 | a = 10 b = 12 | 24 | 0.95 | 65 | 2.56 | |
8 | 0.32 | a = 12 b = 14 | 26 | 1 | 67 | 2.64 | ||
Male thread G1/8 | - | - | a = 14 | 18 | 0.71 | 59 | 2.32 | |
Female thread G1/8 | - | - | a = 14 | 12 | 0.47 | 53 | 2 | |
Male thread G1/8 | - | - | a = 10 | 20 | 0.79 | 61 | 2.40 |
Connection with current output 4 ... 20 mA and plug to EN 175301-803-A
Connection with current output 4 ... 20 mA and round connector
Connection with current output 4 ... 20 mA and permanently fixed cable
Connection with voltage output 0 ... 5 V DC (0 ... 10 V DC) and plug to EN 175301-803-A
Connection with voltage output 0 ... 5 V DC (0 ... 10 V DC) and round connector
Connection with voltage output 0 ... 5 V DC (0 ... 10 V DC) and permanently fixed cable