SCALANCE XR-300 managed производства Siemens

SCALANCE XR-300 managed

The SCALANCE XR-300 Industrial Ethernet switches are fully modular, high-performance, industry-standard switches for the construction of electrical and optical line, ring and star topologies with data transfer rates of 10/100/1000 Mbit/s, designed for installation in 19" control cabinets.

  • As many as 24 electrical and/or optical interfaces (10/100/1000 Mbit/s);
    up to12 electrical and/or optical 2-port media modules can be inserted at any position in the basic unit
  • High-speed media redundancy through integral redundancy manager both for Gigabit Ethernet (with SCALANCE X-300, X-400) and Fast Ethernet (e.g. in combination with SCALANCE X-200 switches)
  • Seamless integration of automation networks into existing corporate networks thanks to support for a host of IT standard functions (VLANs, IGMP-Snooping/Querier, STP/RSTP, Link Aggregation, Quality of Service)
  • Redundant integration into higher-level networks thanks to support for standardized redundancy procedures (Spanning Tree Protocol/Rapid Reconfiguration Spanning Tree Protocol/MRP)
  • Remote diagnostics by means of PROFINET diagnostics, Web browser, CLI, or SNMP

The SCALANCE XR-300 is ideal for use in plant networks and for integrating the industrial network into an existing corporate network. Both at the field level and the control level, the switch performs the network with the distributed field devices and ensures high plant availability with extensive diagnostics options and high transmission speeds. The modularity permits perfect adaptation to the respective application through the use of electrical and also optical media modules

The SCALANCE XR-300 switch is suitable for establishing electrical and optical Industrial Ethernet line, star or ring topologies with 24 ports that can be optionally equipped with electrical and/or optical 2-port media modules. It can also be used as a hub in the plant bus (redundant connection is possible).

Integration of control cabinets with SCALANCE X-300 in an optical Gigabit ring

The use of media modules in partly and fully modular versions of the SCALANCE X-300 switches supports:

  • The extension of networks by subsequent insertion of additional media modules in unused media module slots
  • The changing of cabling technology, e.g. conversion from copper to fiber-optic cables, or from multimode to single-mode FOC
  • Unlimited flexibility during network expansions (e.g. more terminals) or conversion (e.g. switching from copper to fiber-optic cable) and reduction of the storage costs due to the modular construction using port modules
  • High availability of the network thanks to:
    • Redundant power supply
    • Redundant network structures based on fiber-optic or twisted pair cables (redundancy manager, standby function, and STP/RSTP are integrated)
    • Easy device replacement by means of plug-in C-PLUG swap medium
    • Very fast reconfiguration of the network in the event of a fault
  • Lower susceptibility to failure and higher availability of the plant networking due to latching of the RJ45 FastConnect connectors in the sleeve of the RJ45 port modules
  • Protection of investment due to integration into existing network management systems by means of standardized SNMP access
  • Time saving during engineering, commissioning and in the operating phase of a plant by using the integrated configuration and diagnostics in STEP 7, without additional software
  • Space savings in control cabinet due to flexible cable outlet on the front or rear of the device

The SCALANCE XR-300 Industrial Ethernet switches with rugged metal enclosure with IP30 degree of protection are optimized for installation in the 19" control cabinet. Versions are available with 24 V DC or 230 V AC connection. The connection of the power supply and the data cable outlet are located optionally either at the front or rear of the device.

The switches have:

  • 4-pin terminal block for redundant voltage feed to protected against power failure at 24 V DC
  • 3-pin terminal block for voltage feed in 230 V AC version
  • 2-pin terminal block for connecting the isolated signaling contact for simple display of faults
  • Row of LEDs for indicating status information (power, link status, data transfer, power supply, signal contact)
  • SELECT/SET pushbutton for easy setting of the fault signaling contact on the device
  • Slot for optional C-PLUG swap medium on the side of the device for easy replacement in the event of a fault
  • Console port (serial interface) for on-site parameterization/diagnostics (RJ11 cable to RS232 (9-pin) included in scope of delivery)

The SCALANCE XR-300 switches are available with the following port types:

  • 12 slots for electrical or optical 2-port media modules for multi-mode or single-mode connections; the optical media modules are available in various connection technologies
  • The RJ45 sockets are designed to industry standards with additional sleeves, for connection of the Industrial Ethernet FC°RJ45°Plug°180
  • All electrical Ethernet interfaces support 10/100/1000 Mbit/s,
    all optical Ethernet interfaces support 100 or 1000 Mbit/s
  • The SCALANCE XR-300 switches support Gigabit Ethernet (1000 Mbit/s) at all ports. The 24 ports are divided into three groups of eight ports each (Gigabit Ethernet Blocking). Gigabit Ethernet is supported with full wire speed within each group, but not between the groups.

Product versions

SCALANCE XR324-12M (12 media module slots)

Versions are available with

  • LEDs, power supply connection and data cable outlet on the front
  • LEDs on the front, power supply connection and data cable outlet at the rear

All versions have twelve media module slots and

  • 1 x 24 V DC power supply
  • 1 x 230 V AC power supply

SCALANCE XR-300 with cable outlet at rear

  • Integrated redundancy manager for constructing Fast Ethernet and Gigabit Ethernet ring topologies with high-speed media redundancy. Reliable communication is achieved by closing an optical or electrical line with SCALANCE X-400, X-300 or X-200 switches to form a ring. The redundancy manager (RM) integrated in the SCALANCE XR-300 switch monitors the function of the network. It recognizes the failure of a transmission link or a SCALANCE X switch in the ring and activates the substitute path within a maximum of 0.2 seconds.
  • Redundant interfacing to company networks;
    SCALANCE XR-300 switches support the standardized redundancy procedures Spanning Tree Protocol (STP) and Rapid Spanning Tree Protocol (RSTP). This enables a subnetwork to be connected redundantly to a higher level corporate network with reduced requirements for the reconfiguration time (in the order of seconds).
  • Support of virtual networks (VLAN);
    for structuring Industrial Ethernet networks with a fast growing number of users, a physically existing network can be divided into several virtual networks.
  • Load limiting when multicast protocols (e.g. video transmission) are used;
    through learning the multicast sources and targets (IGMP Snooping, IGMP Querier), SCALANCE XR-300 switches can also filter multicast data traffic and therefore limit the load in the network. Multicast and broadcast traffic can be limited.
  • Time synchronization;
    diagnostic messages (log table entries, e-mails) are time-stamped. The local time is standardized throughout the network by means of synchronization with a SICLOCK time transmitter, thereby simplifying the assignment of diagnostic messages to several devices.
  • Fast replacement of devices in event of failure, by means of the C-PLUG switching medium
  • Link aggregation (IEEE 802.1q) for bundling data streams
  • Quality of Service (IEEE 802.1p) for prioritization of network traffic

Network topology and network configuration

The network topology can easily be adapted to the structure of the plant using SCALANCE XR-300 Industrial Ethernet switches .

The following network structures and combinations of structures can be implemented:

  • Fast Ethernet with fast media redundancy;
    to increase network availability, as many as 50 X-200, X-300, X-400 or X-500 switches cascaded in line can be connected into a ring.
  • Several rings can be redundantly linked through the standby function
  • In addition, SCALANCE XR-300 supports redundant connection of the ring structure to the corporate network with a rapid spanning tree.
  • Star topology with SCALANCE XR-300 switches:
    Each SCALANCE XR-300 switch represents a neutral point that can connect up to 24 nodes or subnets with each other electrically.

When configuring the network, it is necessary to observe the following boundary conditions:

  • Maximum line length between two modules for multi-mode fiber-optic conductors:
    • 5 km at 100 Mbit/s
    • 750 m at 1 Gbit/s
  • Maximum line length between two modules for single-mode fiber-optic conductors:
    • 26 km to 70 km at 100 Mbit/s
    • 10 to 120 km at 1 Gbit/s
  • Maximum cable length of the TP cable between two SCALANCE X switches:
    • Max. 100 m with IE FC cable 2x2 and IE FC RJ45 Plug 180
    • Max. 100 m at 1 Gbit/s with IE FC Standard Cable 4x2 (90 m), IE FC RJ45 Modular Outlet and patch cable (10 m)
    • Max. 10 m using patches with TP Cord

Commissioning and diagnosis

Setting options on the device itself:

  • Redundancy manager RM;
    to establish a ring, a SCALANCE XR-300 is switched to RM mode. The Gigabit ports (electrical or optical) are preferably used as ring ports. The non-ring ports of the RM can be used freely for the connection of data terminals and networks. If the redundancy procedure MRP standardized by PROFINET is used, the RM is adjusted automatically.
  • Signal mask;
    the signal mask is set to the current status of the SCALANCE XR-300 (setpoint) by pushbutton operation. The signal mask defines which ports and which power supplies are to be monitored. The signaling contact only reports an error when a monitored port or a monitored feeder fails (deviation of setpoint/actual status).
  • IP address;
    the IP address is assigned via DHCP (Dynamic Host Configuration Protocol). If there is no corresponding server in the network, the IP address can be assigned using an enclosed software tool.

Diagnostic options on site:

  • The following status information is displayed by LEDs on site:
    • Port status
    • Port mode (10/100/1000 Mbit/s, full/half-duplex)
    • Status of the two power supplies
    • Signaling contact status
    • Signal mask (setpoint status)
    • RM mode
    • Standby mode
  • The status of the signaling contact is routed externally by means of floating relay contacts. This enables, for example, the module to be monitored via an input module from a controller.
  • Monitoring via the Industrial Ethernet network;
    the following possibilities are available:
    • Remote via standard browser (Web-based management):
      Selection of SCALANCE XR-300 switches via the network from a PC with browser
    • Remote via SNMP V1, V2c, V3:
      Secure integration of SCALANCE XR-300 switches via the network into a network management system, e.g. SINEMA Server
    • Remote via PROFINET IO diagnostics:
      PROFINET diagnostic alarms from SCALANCE X-300 switches can be displayed using the relevant SIMATIC engineering tools and they can also be processed in the controller. The engineering outlay for the PLC and HMI have been drastically reduced due to the complete integration in the SIMATIC concept for system error messages.

Network management

The network management provides the following functions:

  • Password-protected dial-up for "Administrator" (read and write authorization) and "User" (read only)
  • Read-out of version and status information
  • Setting the signal and standby mask and address information
  • Fixed parameterization of the ports (data rates, half/full duplex)
  • Setting of Spanning/Rapid Spanning Tree parameters
  • Parameterization of the web management services
  • Security
    • Ports can be connected or disconnected
    • Port-based network access control according to IEEE 802.1x
    • Authentication in accordance with IEEE 802.1x (available soon)
    • Support of Access Control List (ACL) (available soon)
  • Output of statistics information
  • Diagnosis of data traffic by means of a parameterizable mirror port with a standard commercial network analyzer
  • Loading of new firmware versions or of the configuration data via the network by a TFTP server or directly via HTTP/HTTPS using a Web browser
  • Saving the configuration data or log table via the network on a TFTP server

If faults occur in the network, the SCALANCE XR-300 switch can independently send error messages (traps) to a network management system or also e-mails to a predefined network administrator.

Remote monitoring (RMON) provides the following functions:
The SCALANCE XR-300 switch can collect statistics information according to the RMON groups 1 through 4. These include, for example, fault statistics that are kept for each port. This information can be read out through web-based management in the statistics sub-area.

Order No.

6GK5 324-0GG00-1AR2

6GK5 324-0GG00-1HR2

6GK5 324-0GG00-3AR2

6GK5 324-0GG00-3HR2

Product type designation

SCALANCE XR324-12M

SCALANCE XR324-12M

SCALANCE XR324-12M

SCALANCE XR324-12M

Transmission rate

 

 

 

 

Transfer rate 1

10 Mbit/s

10 Mbit/s

10 Mbit/s

10 Mbit/s

Transfer rate 2

100 Mbit/s

100 Mbit/s

100 Mbit/s

100 Mbit/s

Transfer rate 3

1 000 Mbit/s

1 000 Mbit/s

1 000 Mbit/s

1 000 Mbit/s

Interfaces

 

 

 

 

Number of electrical/optical connections for network components or terminal equipment maximum

24

24

24

24

Number of electrical connections

 

 

 

 

  • for network components and terminal equipment

-

-

-

-

  • for operator console

1

1

1

1

  • for alarm contact

1

1

1

1

  • for media module

12

12

12

12

  • for power supply

1

1

1

1

  • for redundant power supply

1

1

0

0

Design of electrical connection

 

 

 

 

  • for network components and terminal equipment

Dependent on selected media modules

Dependent on selected media modules

Dependent on selected media modules

Dependent on selected media modules

  • for operator console

RJ11 port

RJ11 port

RJ11 port

RJ11 port

  • for signaling contact

2-pole terminal block

2-pole terminal block

2-pole terminal block

2-pole terminal block

  • for power supply

4-pole terminal block

4-pole terminal block

2-pole terminal block

2-pole terminal block

Number of optical interfaces for optical waveguide

 

 

 

 

  • at 100 Mbit/s

-

-

-

-

  • at 1000 Mbit/s

-

-

-

-

Design of optical interface for optical waveguide

 

 

 

 

  • at 100 Mbit/s

Dependent on selected media modules

Dependent on selected media modules

Dependent on selected media modules

Dependent on selected media modules

  • at 1000 Mbit/s

Dependent on selected media modules

Dependent on selected media modules

Dependent on selected media modules

Dependent on selected media modules

Connectable optical power relative to 1 mW

 

 

 

 

  • of the transmitter output

- -

- -

- -

- -

  • of the receiver input maximum

-

-

-

-

Optical sensitivity relative to 1 mW of the receiver input minimum

-

-

-

-

Attenuation of fiber-optic cable transmission link minimum necessary

-

-

-

-

Range at the optical interface depending on the optical fiber used

- -

- -

- -

- -

design of the removable storage C-PLUG

Yes

Yes

Yes

Yes

Inputs/outputs

 

 

 

 

Operating voltage of signaling contacts at AC rated value

-

-

-

-

Operating current of signaling contacts at AC maximum

-

-

-

-

Operating voltage of signaling contacts at DC rated value

24 V

24 V

24 V

24 V

Operating current of signaling contacts at DC maximum

0.1 A

0.1 A

0.1 A

0.1 A

Supply voltage, current consumption, power loss

 

 

 

 

Type of supply voltage redundant power supply unit

No

No

No

No

Type of voltage of supply voltage

DC

DC

AC

AC

Supply voltage external

24 V

24 V

230 V

230 V

  • minimum

19.2 V

19.2 V

85 V

85 V

  • maximum

28.8 V

28.8 V

264 V

264 V

Product component fusing at power supply input

Yes

Yes

Yes

Yes

Type of fusing at input for supply voltage

 

 

 

 

Consumed current maximum

1.8 A

1.8 A

0.8 A

0.8 A

Active power loss

 

 

 

 

  • at 24 V for DC

44 W

44 W

-

-

  • at 230 V AC

-

-

50 W

50 W

Permitted ambient conditions

 

 

 

 

Ambient temperature

 

 

 

 

  • during operating

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

  • during storage

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

  • during transport

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

  • Comment

Reduced operating temperature through the use of media modules (-40 °C to +70 °C) or SFP plug-in transceivers (-40 °C to +60 °C). If the device is installed in the vertical position, the maximum operating temperature is reduced to +50 °C.

Reduced operating temperature through the use of media modules (-40 °C to +70 °C) or SFP plug-in transceivers (-40 °C to +60 °C). If the device is installed in the vertical position, the maximum operating temperature is reduced to +50 °C.

Reduced operating temperature through the use of media modules (-40 °C to +70 °C) or SFP plug-in transceivers (-40 °C to +60 °C). If the device is installed in the vertical position, the maximum operating temperature is reduced to +50 °C.

Reduced operating temperature through the use of media modules (-40 °C to +70 °C) or SFP plug-in transceivers (-40 °C to +60 °C). If the device is installed in the vertical position, the maximum operating temperature is reduced to +50 °C.

Relative humidity at 25 °C without condensation during operating maximum

95 %

95 %

95 %

95 %

Ambient condition for (standard) operation mode

-

-

-

-

Protection class IP

IP20

IP20

IP20

IP20

Design, dimensions and weight

 

 

 

 

Design

19" rack

19" rack

19" rack

19" rack

Width

483 mm

483 mm

483 mm

483 mm

Height

44 mm

44 mm

44 mm

44 mm

Depth

305 mm

305 mm

305 mm

305 mm

Net weight

5.5 kg

5.5 kg

5.9 kg

5.9 kg

Type of mounting

 

 

 

 

  • Installation 19 inch

Yes

Yes

Yes

Yes

  • 35 mm DIN rail mounting

No

No

No

No

  • wall mounting

No

No

No

No

  • S7-300 rail mounting

No

No

No

No

Type of mounting

When used in shipbuilding, the device must be secured in the 19" rack at four points

When used in shipbuilding, the device must be secured in the 19" rack at four points

When used in shipbuilding, the device must be secured in the 19" rack at four points

When used in shipbuilding, the device must be secured in the 19" rack at four points

Product properties, functions, componentsgeneral

 

 

 

 

Cascading in the case of a redundant ring at reconfiguration time of <'~0.3'~s

50

50

50

50

Cascading in cases of star structuring

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Product functionsmanagement, configuration

 

 

 

 

Product function

 

 

 

 

  • CLI

Yes

Yes

Yes

Yes

  • web-based management

Yes

Yes

Yes

Yes

  • MIB support

Yes

Yes

Yes

Yes

  • TRAPs via email

Yes

Yes

Yes

Yes

  • Configuration with STEP 7

Yes

Yes

Yes

Yes

  • RMON

Yes

Yes

Yes

Yes

  • SMTP server

Yes

Yes

Yes

Yes

  • Port mirroring

Yes

Yes

Yes

Yes

  • CoS

Yes

Yes

Yes

Yes

  • for IRT PROFINET IO switch

-

-

-

-

  • PROFINET IO diagnosis

Yes

Yes

Yes

Yes

  • switch-managed

Yes

Yes

Yes

Yes

Protocol is supported

 

 

 

 

  • Telnet

Yes

Yes

Yes

Yes

  • HTTP

Yes

Yes

Yes

Yes

  • HTTPS

Yes

Yes

Yes

Yes

  • TFTP

Yes

Yes

Yes

Yes

  • FTP

Yes

Yes

Yes

Yes

  • BOOTP

Yes

Yes

Yes

Yes

  • SNMP v1

Yes

Yes

Yes

Yes

  • SNMP v2

Yes

Yes

Yes

Yes

  • SNMP v3

Yes

Yes

Yes

Yes

  • IGMP (snooping/querier)

Yes

Yes

Yes

Yes

  • GMRP

Yes

Yes

Yes

Yes

  • DCP

Yes

Yes

Yes

Yes

  • LLDP

Yes

Yes

Yes

Yes

Identification & maintenance

 

 

 

 

  • I&M0 - device-specific information

Yes

Yes

Yes

Yes

  • I&M1 - plant identification/location name

Yes

Yes

Yes

Yes

Product functionsDiagnosis

 

 

 

 

Product function

 

 

 

 

  • Port diagnostics

Yes

Yes

Yes

Yes

  • Statistics Packet Size

Yes

Yes

Yes

Yes

  • Statistics packet type

Yes

Yes

Yes

Yes

  • Error statistics

Yes

Yes

Yes

Yes

  • SysLog

Yes

Yes

Yes

Yes

Product functionsVLAN

 

 

 

 

Product function

 

 

 

 

  • VLAN - port based

Yes

Yes

Yes

Yes

  • VLAN dynamic

Yes

Yes

Yes

Yes

Number of VLANs maximum

255

255

255

255

Number of VLANs - dynamic maximum

255

255

255

255

Protocol is supported GVRP

Yes

Yes

Yes

Yes

Product functionsDHCP

 

 

 

 

Product function

 

 

 

 

  • DHCP client

Yes

Yes

Yes

Yes

  • DHCP Option 82

Yes

Yes

Yes

Yes

  • DHCP Option 66

Yes

Yes

Yes

Yes

  • DHCP Option 67

Yes

Yes

Yes

Yes

Product functionsRedundancy

 

 

 

 

Product function

 

 

 

 

  • Ring redundancy

Yes

Yes

Yes

Yes

  • Redundancy manager

Yes

Yes

Yes

Yes

  • Standby redundancy

Yes

Yes

Yes

Yes

  • HSR redundancy protocol

Yes

Yes

Yes

Yes

  • MRP redundancy protocol

Yes

Yes

Yes

Yes

  • redundancy procedure STP

Yes

Yes

Yes

Yes

  • RSTP redundancy protocol

Yes

Yes

Yes

Yes

  • Passive listening

Yes

Yes

Yes

Yes

Protocol is supported

 

 

 

 

  • STP/RSTP

Yes

Yes

Yes

Yes

  • STP

Yes

Yes

Yes

Yes

  • RSTP

Yes

Yes

Yes

Yes

  • RSTP big network support

Yes

Yes

Yes

Yes

  • LACP

Yes

Yes

Yes

Yes

Product functionsSecurity

 

 

 

 

Product function

 

 

 

 

  • ACL - port/MAC-based

Yes

Yes

Yes

Yes

  • IEEE 802.1x (radius)

Yes

Yes

Yes

Yes

  • Broadcast/Multicast/Unicast Limiter

Yes

Yes

Yes

Yes

  • broadcast blocking

Yes

Yes

Yes

Yes

Protocol is supported SSH

Yes

Yes

Yes

Yes

Product functionsTime

 

 

 

 

Product function SICLOCK support

Yes

Yes

Yes

Yes

Protocol is supported

 

 

 

 

  • NTP

No

No

No

No

  • SNTP

Yes

Yes

Yes

Yes

  • IEEE 1588 profile default

Yes

Yes

Yes

Yes

  • IEEE 1588 profile gPTP

-

-

-

-

  • IEEE 1588 profile PSRC

-

-

-

-

Type of time synchronization

-

-

-

-

Standards, specifications, approvals

 

 

 

 

Standard

 

 

 

 

  • for EMC from FM

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

No

No

  • for hazardous zone

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

 

 

  • for safety of CSA and UL

UL 60950-1, CSA C22.2 No. 60950-1-03

UL 60950-1, CSA C22.2 No. 60950-1-03

UL 508, CSA C22.2 No. 142-M1987

UL 508, CSA C22.2 No. 142-M1987

  • for hazardous area of CSA and UL

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

No

No

  • for emitted interference

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

  • for interference immunity

EN 61000-6-2:2005

EN 61000-6-2:2005

EN 61000-6-2:2005

EN 61000-6-2:2005

Verification of suitability

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

  • CE mark

Yes

Yes

Yes

Yes

  • C-Tick

Yes

Yes

Yes

Yes

  • Railway application in accordance with EN 50155

-

-

-

-

  • Railway application in accordance with EN 50124-1

-

-

-

-

Marine classification association

 

 

 

 

  • American Bureau of Shipping Europe Ltd. (ABS)

-

-

-

-

  • Bureau Veritas (BV)

-

-

-

-

  • Det Norske Veritas (DNV)

-

-

-

-

  • Germanische Lloyd (GL)

-

-

-

-

  • Lloyds Register of Shipping (LRS)

-

-

-

-

  • Nippon Kaiji Kyokai (NK)

-

-

-

-


To assist in selecting the right Industrial Ethernet switches as well as configuration of modular variants, the SIMATIC NET Selection Tool is available:

Online version:
http://www.siemens.com/snst

Offline version:
http://www.siemens.com/snst-download

Код Заказной номер Описание Вес (кг) Заказать
110331 6EP1332-5BA00 sitop psu100c 24 v/2.5 a стабилизированный блок питания, вход: ~120-230 в, выход: =24 в/2.5 a 0.22 Заказать
66407 6GK1900-0AB00 simatic net, c-plug, съемный модуль памяти для хранения параметров конфигурации компонентов simatic net. при необходимости в нем могут сохраняться данные пользователя. например, файловая система cp443-1 advanced 0.03 Заказать
114451 6GK1901-1BB10-2AA0 simatic net ie fc rj45 штекер, 180 rj45, штекерный соединитель с метал. корпусом для пром. условий, предназначен для быстрого монтажа, 180 град. угол вывода кабеля, 1 упаковка = 1 шт. 0.03 Заказать
114452 6GK1901-1BB10-2AB0 simatic net ie fc rj45 штекер, 180 rj45, штекерный соединитель с метал. корпусом для пром. условий, предназначен для быстрого монтажа, 180 град. угол вывода кабеля, 1 упаковка = 10 шт. 0.3 Заказать
66419 6GK1901-1BB10-2AE0 simatic net ie fc rj45 штекер, 180 rj45, штекерный соединитель с метал. корпусом для пром. условий, предназначен для быстрого монтажа, 180 град. угол вывода кабеля, 1 упаковка = 50 шт. 1.5 Заказать
66421 6GK1901-1BB11-2AA0 ie fc rj45 plug 180 4x2, rj45 соединитель-розетка (10/100/1000мбит/с) в прочном металлическом корпусе, метод подключчения fc, для ie fc кабеля 4x2 (awg24) выход кабеля под углом 180 градусов, 1 упаковка = 1 штука 0.022 Заказать
114453 6GK1901-1BB11-2AB0 ie fc rj45 plug 180 4x2, rj45 соединитель-розетка (10/100/1000мбит/с) в прочном металлическом корпусе, метод подключчения fc, для ie fc кабеля 4x2 (awg24) выход кабеля под углом 180 градусов, 1 упаковка = 10 штук 0.22 Заказать
114454 6GK1901-1BB11-2AE0 ie fc rj45 plug 180 4x2, rj45 соединитель-розетка (10/100/1000мбит/с) в прочном металлическом корпусе, метод подключчения fc, для ie fc кабеля 4x2 (awg24) выход кабеля под углом 180 градусов, 1 упаковка = 50 штук 1.1 Заказать
114458 6GK1901-1BE00-0AA1 simatic net ie fc rj45 основной модуль модульной розетки, со вставкой 2fe для подсоединения двух интерфейсов 100 мбит/с 0.4 Заказать
66427 6GK1901-1BE00-0AA2 simatic net ie fc rj45 основной модуль модульной розетки, со вставкой 1ge для подсоединения одного интерфейса 1000 мбит/с 0.4 Заказать
66450 6GK1975-1AA00-3AA0 simatic net, коллекция руководств по системам, протоколам, продуктам,... издание 2007, наdvd, нем./англ. 0.018 Заказать
114526 6GK5324-0GG00-1AR2 scalance xr324-12m managed ie switch, 19" rack, power supply 24v dc, data cable outlet front side, 12 x 100/1000mbit/s f. 2-port- media modules, elektrical oder optical, led-diagnostics, fault signal contact with select/set button, profinet-io device, network- management, integrated redundancy manager, office features (rstp, vlan, igmp,..) c-plug in the scope of supply 5 Заказать
114527 6GK5324-0GG00-1HR2 scalance xr324-12m managed ie switch, 19" rack, power supply 24v dc, data cable outlet back side, 12 x 100/1000mbit/s f. 2-port- media modules, elektrical oder optical, led-diagnostics, fault signal contact with select/set button, profinet-io device, network- management, integrated redundancy manager office features (rstp, vlan, igmp,..); c-plug in the scope of supply 5 Заказать
114528 6GK5324-0GG00-3AR2 scalance xr324-12m managed ie switch, 19" rack; power supply 230v ac; data cable outlet front side; 12 x 100/1000mbit/s f. 2-port- media modules, elektrical oder optical; led-diagnostics; fault signal contact; with select/set button; profinet-io device, network- management, integrated redundancy manager office features (rstp, vlan, igmp,..); c-plug in the scope of supply 0.3 Заказать
114529 6GK5324-0GG00-3HR2 scalance xr324-12m managed managed ie switch, 19" rack; power supply 230v ac; data cable outlet back side; 12 x 100/1000mbit/s f. 2-port- media modules, elektrical oder optical; led-diagnostics; fault signal contact; with select/set button; profinet-io device, network- management, integrated redundancy manager office features (rstp, vlan, igmp,..); c-plug in the scope of supply 0.3 Заказать
114595 6GK5991-1AD00-8AA0 scalance x accessory, sfp991-1 1 x 100mbit/s lc-port optical multimode glass up to max. 3 km 0.3 Заказать
114596 6GK5991-1AE00-8AA0 scalance x accessory, sfp991-1lh+ 1 x 100mbit/s lc-port optical singlemode glass up to max. 70 km 0.3 Заказать
114597 6GK5991-1AF00-8AA0 scalance x accessory, sfp991-1ld 1 x 100mbit/s lc-port optical singlemode glass up to max. 26 km 0.3 Заказать
66546 6GK5991-2AB00-8AA0 scalance x accessory, media module mm991-2, 2 x 100mbit/s bfoc-ports optical multimode glass up to max. 3 km 0.3 Заказать
114598 6GK5991-2AC00-8AA0 scalance x accessory, media module mm991-2ld, 2 x 100mbit/s bfoc-ports optical singlemode glass up to max. 26 km 0.3 Заказать
66547 6GK5991-2AD00-8AA0 scalance x accessory, media module mm991-2, 2 x 100mbit/s sc-ports optical multimode glass up to max. 3 km 0.3 Заказать
114599 6GK5991-2AE00-8AA0 scalance x accessory, media module mm991-2lh+, 2 x 100mbit/s sc-ports optical singlemode glass up to max. 70 km 0.3 Заказать
114600 6GK5991-2AF00-8AA0 scalance x accessory, media module mm991-2ld, 2 x 100mbit/s sc-ports optical singlemode glass up to max. 26 km 0.3 Заказать
66548 6GK5992-1AL00-8AA0 scalance x accessory, sfp992-1 1 x 1000mbit/s lc-port, optical multimode glass up to max. 750 m 0.3 Заказать
66549 6GK5992-1AM00-8AA0 scalance x accessory, sfp992-1ld 1 x 1000mbit/s lc-port, optical singlemode glass up to max. 10 km 0.3 Заказать
66550 6GK5992-1AN00-8AA0 scalance x accessory, sfp992-1lh 1 x 1000mbit/s lc-port, optical singlemode glass up to max. 40 km 0.3 Заказать
114601 6GK5992-1AP00-8AA0 scalance x accessory, sfp992-1lh+ 1 x 1000mbit/s lc-port, optical singlemode glass up to max. 70 km 0.3 Заказать
114602 6GK5992-1AQ00-8AA0 scalance x accessory, sfp992-1elh 1 x 1000mbit/s lc-port, optical singlemode glass optical singlemode glass up to max. 120 km 0.3 Заказать
66551 6GK5992-2AL00-8AA0 scalance x accessory, media module mm992-2, 2 x 1000mbit/s sc-ports, optical multimode glass up to max. 750 m 0.3 Заказать
114603 6GK5992-2AM00-8AA0 scalance x accessory, media module mm992-2ld, 2 x 1000mbit/s sc-ports, optical singlemode glass up to max. 10 km 0.3 Заказать
66552 6GK5992-2AN00-8AA0 scalance x accessory, media module mm992-2lh, 2 x 1000mbit/s sc-ports, optical singlemode glass up to max. 40km 0.3 Заказать
66553 6GK5992-2AP00-8AA0 scalance x accessory, media module mm992-2lh+, 2 x 1000mbit/s sc-ports, optical singlemode glass up to max. 70km 0.3 Заказать
66554 6GK5992-2AQ00-8AA0 scalance x accessory, media module mm992-2elh, 2 x 1000mbit/s sc-ports, optical singlemode glass up to max. 120km 0.3 Заказать
114604 6GK5992-2AS00-8AA0 scalance x accessory, media module mm992-2sfp, 2 x 100/1000mbit/s sfp sfp plug transceiver 0.3 Заказать
114605 6GK5992-2GA00-8AA0 scalance x accessory, media module mm992-2cuc, 2 x 1000mbit/s rj45-ports, electrical, with sleeve 0.3 Заказать
66555 6GK5992-2SA00-8AA0 scalance x accessory, media module mm992-2cu, 2 x 1000mbit/s rj45-ports, electrical, without sleeve 0.3 Заказать
70514 6XV1840-2AH10 simatic net, fc стандартный ie tp кабель для быстрого монтажа (fc), для подкл. к fc соединителю rj45, 4-жильный, экранированный, категория 5, поставка по метражу отрезками длиной 20 ... 1000 m 0.068 Заказать
70586 6XV1870-2E simatic net, ethernet fc стандартный инсталяционный кабель; категории 6 для соединения fc rj45 модульной розетки, продаётся в метрах, макс. поставка 1000 m, мин. заказная длина: 20 m 0.093 Заказать
117054 6XV1870-3QE50 simatic net industrial ethernet tp корд rj45/rj45, категории 6, tp кабель 4x2, предсобранный с 2-мя rj45 разъёмами, l = 0.5 m 0.039 Заказать
117055 6XV1870-3QH10 simatic net industrial ethernet tp корд rj45/rj45, категории 6, tp кабель 4x2, предсобранный с 2-мя rj45 разъёмами, l = 1 m 0.052 Заказать
70588 6XV1870-3QH20 simatic net industrial ethernet tp корд rj45/rj45, категории 6, tp кабель 4x2, предсобранный с 2-мя rj45 разъёмами, l = 2 m 0.114 Заказать
70589 6XV1870-3QH60 simatic net industrial ethernet tp корд rj45/rj45, категории 6, tp кабель 4x2, предсобранный с 2-мя rj45 разъёмами, l = 6 m 0.217 Заказать
70590 6XV1870-3QN10 simatic net industrial ethernet tp корд rj45/rj45, категории 6, tp кабель 4x2, предсобранный с 2-мя rj45 разъёмами, l = 10 m 0.349 Заказать
;