SIPLUS extreme products are based on Siemens Industry standard products. The contents listed here were taken from the respective standard products. SIPLUS extreme-specific information was added.
SIPLUS S7-400 PS | ||
---|---|---|
Order No. | 6AG1 405-0KA02-2AA0 | 6AG1 407-0KR02-4AA0 |
Order No. based on | 6ES7 405-0KA02-0AA0 | 6ES7 407-0KR02-0AA0 |
Ambient temperature range | -25 ... +70 °C | -0 ... +60 °C |
Conformal coating | Coating of the printed circuit boards and the electronic components | |
Technical data | The technical data of the standard product applies, except for the environmental conditions | |
Environmental conditions | ||
Relative humidity | 5 ... 100 % | |
Biologically active substances | Conformity with EN 60721‑3‑3, Class 3B2 mold and fungal spores (except fauna) | |
Chemically active substances | Conformity with EN 60721‑3‑3, Class 3C4 incl. salt mist and ISA–S71.04 severity level G1; G2; G3; GX 1)2) | |
Mechanically active substances | Conformity with EN 60721‑3‑3, Class 3S4 including sand, dust 2) | |
Air pressure (depending on the highest positive temperature range specified) | 1080 ... 795 hPa (-1000 ... +2000 m) 795 ... 658 hPa (+2000 ... +3500 m) 658 ... 540 hPa (+3500 ... +5000 m) |
1) ISA-S71.04 severity level GX: Long-term load: SO2 < 4.8 ppm; H2S < 9.9 ppm; Cl < 0.2 ppm; HCl < 0.66 ppm; HF < 0.12 ppm; NH < 49 ppm; O3 < 0.1 ppm; NOX < 5.2 ppm
Limit value (max. 30 min/d): SO2 < 14.8 ppm; H2S < 49.7 ppm; Cl < 1.0 ppm; HCl < 3.3 ppm; HF < 2.4 ppm; NH < 247 ppm; O3 < 1.0 ppm; NOX < 10.4 ppm
2) The supplied plug covers must remain in place over the unused interface when operated in atmospheres containing corrosive gases!
For further technical documentation on SIPLUS, see:
http://www.siemens.com/siplus-extreme
The power supplies supply the S7-400 modules with their 5 V DC and 24 V DC operating voltages via the backplane bus.
Power supplies are available for AC line voltages of 85 to 264 V and for DC voltages of 19.2 to 300 V.
One power supply module is required per rack.
Exception:
With interfaces with current transfer, the power supply module in the central controller also supplies all modules in the expansion units.
The load voltage for supplying sensors and actuators must be made available separately.
There are also power supplies to make both the standard system and the H system fail-safe (redundant power supplies).
The power supply modules are inserted at the far left in the rack (starting from slot 1). Depending on the version, they occupy slots 1 to 3. The modules are enclosed and are cooled via natural convection.
The front of the module contains:
The back-up battery is optional and must be ordered in addition. For power supplies at and above 10 A, two back-up batteries are recommended.
| 6ES7 405-0DA02-0AA0 | 6ES7 405-0KA02-0AA0 | 6ES7 405-0KR02-0AA0 | 6ES7 405-0RA02-0AA0 |
| PS405, 24 VDC, 5 VDC/4 A | PS405, 24/48/60 VDC, 5 VDC/10 A | PS405,24/48/60 VDC,5 VDC/10 A,RED | PS405, 24/48/60 VDC, 5 VDC/20 A |
Supply voltage |
|
|
|
|
Rated value, 24 V DC | Yes | Yes | Yes | Yes |
Rated value, 48 V DC | Yes | Yes | Yes | Yes |
Rated value, 60 V DC | Yes | Yes | Yes | Yes |
permissible range, lower limit (DC) | 19.2 V; Dynamic 18.5 V | 19.2 V; Dynamic 18.5 V | 19.2 V; Dynamic 18.5 V | 19.2 V; Dynamic 18.5 V |
permissible range, upper limit (DC) | 72 V; dynamic 75.5 V | 72 V; dynamic 75.5 V | 72 V; dynamic 75.5 V | 72 V; dynamic 75.5 V |
Mains buffering |
|
|
|
|
| 20 ms | 20 ms | 20 ms | 20 ms |
| Yes | Yes | Yes | Yes |
Input current |
|
|
|
|
Rated value at 24 V DC | 2 A | 4 A | 4 A | 7 A |
Rated value at 48 V DC | 1 000 mA | 2 A | 2 A | 3.2 A |
Rated value at 60 V DC | 800 mA | 1.6 A | 1.6 A | 2.5 A |
Inrush current, max. | 18 A; Full width at half maximum 20 ms | 18 A; Full width at half maximum 20 ms | 18 A; Full width at half maximum 20 ms | 56 A; Full width at half maximum 1.5 ms |
Output voltage |
|
|
|
|
Rated value, 5 V DC | Yes | Yes | Yes | Yes |
Rated value, 24 V DC | Yes | Yes | Yes | Yes |
Output current |
|
|
|
|
for backplane bus (5 V DC), max. | 4 A; no base load required | 10 A; no base load required | 10 A; no base load required | 20 A; no base load required |
for backplane bus (24 V DC), max. | 0.5 A; idling-proof | 1 A; idling-proof | 1 A; idling-proof | 1 A; idling-proof |
Short-circuit protection | Yes | Yes | Yes | Yes |
Power |
|
|
|
|
Power consumption, typ. | 48 W | 95 W | 95 W | 168 W |
Power losses |
|
|
|
|
Power loss, typ. | 16 W | 20 W | 20 W | 44 W |
Backup battery |
|
|
|
|
Backup battery |
|
|
|
|
| Yes; 1 x lithium AA; 3.6 V/2.3 Ah | Yes; 2 x lithium AA; 3.6 V/2.3 Ah | Yes; 2 x lithium AA; 3.6 V/2.3 Ah | Yes; 2 x lithium AA; 3.6 V/2.3 Ah |
Galvanic isolation |
|
|
|
|
primary/secondary | Yes | Yes | Yes | Yes |
Degree and class of protection |
|
|
|
|
Protection class | 1; with protective conductor | 1; with protective conductor | 1; with protective conductor | 1; with protective conductor |
Standards, approvals, certificates |
|
|
|
|
FM approval | Yes; Ta: 0 °C to 60 °C T4 | Yes; Ta: 0 °C to 60 °C T4 | Yes; Ta: 0 °C to 60 °C T4 | Yes; Ta: 0 °C to 60 °C T4 |
Connection method |
|
|
|
|
Connecting cables/cross sections | 3 x 1.5 mm2, solid or stranded wire with end sleeve, external diameter 3 to 9 mm | 3 x 1.5 mm2, solid or stranded wire with end sleeve, external diameter 3 to 9 mm | 3 x 1.5 mm2, solid or stranded wire with end sleeve, external diameter 3 to 9 mm | 3 x 1.5 mm2, solid or stranded wire with end sleeve, external diameter 3 to 9 mm |
Dimensions |
|
|
|
|
Width | 25 mm | 50 mm | 50 mm | 50 mm |
Height | 290 mm | 290 mm | 290 mm | 290 mm |
Depth | 217 mm | 217 mm | 217 mm | 217 mm |
Required slots | 1 | 2 | 2 | 2 |
Weight |
|
|
|
|
Weight, approx. | 760 g | 1 200 g | 1 200 g | 1 300 g |
| 6ES7 407-0DA02-0AA0 | 6ES7 407-0KA02-0AA0 | 6ES7 407-0KR02-0AA0 | 6ES7 407-0RA02-0AA0 |
Supply voltage |
|
|
|
|
Rated value, 110 V DC | Yes; Rated value 120 V DC | Yes; Rated value 120 V DC | Yes; Rated value 120 V DC | Yes; Rated value 120 V DC |
Rated value, 230 V DC | Yes | Yes | Yes | Yes |
permissible range, lower limit (DC) | 88 V | 88 V | 88 V | 88 V |
permissible range, upper limit (DC) | 300 V | 300 V | 300 V | 300 V |
Rated value, 120 V AC | Yes | Yes | Yes | Yes |
Rated value, 230 V AC | Yes | Yes | Yes | Yes |
Line frequency |
|
|
|
|
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| 47 Hz | 47 Hz | 47 Hz | 47 Hz |
| 63 Hz | 63 Hz | 63 Hz | 63 Hz |
Mains buffering |
|
|
|
|
| 20 ms | 20 ms | 20 ms | 20 ms |
| Yes | Yes | Yes | Yes |
Input current |
|
|
|
|
Rated value at 110 V DC | 350 mA; at 120 V DC | 1 A; at 120 V DC | 1 A; at 120 V DC | 1.4 A; at 120 V DC |
Rated value at 230 V DC | 190 mA | 0.5 A | 0.5 A | 0.7 A |
Rated value at 120 V AC | 0.42 A | 0.9 A | 0.9 A | 1.4 A |
Rated value at 230 V AC | 0.22 A | 0.5 A | 0.5 A | 0.7 A |
Inrush current, max. | 8.25 A; Full width at half maximum 5 ms | 63 A; Full width at half maximum 1 ms | 63 A; Full width at half maximum 1 ms | 88 A; Full width at half maximum 1.1 ms |
Output voltage |
|
|
|
|
Rated value, 5 V DC | Yes | Yes | Yes | Yes |
Rated value, 24 V DC | Yes | Yes | Yes | Yes |
Output current |
|
|
|
|
for backplane bus (5 V DC), max. | 4 A; no base load required | 10 A; no base load required | 10 A; no base load required | 20 A; no base load required |
for backplane bus (24 V DC), max. | 0.5 A; idling-proof | 1 A; idling-proof | 1 A; idling-proof | 1 A; idling-proof |
Short-circuit protection | Yes | Yes | Yes | Yes |
Power |
|
|
|
|
Power consumption, typ. | 52 W | 95 W | 95 W | 158 W |
Power losses |
|
|
|
|
Power loss, typ. | 20 W | 20 W | 20 W | 35 W |
Backup battery |
|
|
|
|
Backup battery |
|
|
|
|
| Yes; 1 x lithium AA; 3.6 V/2.3 Ah | Yes; 2 x lithium AA; 3.6 V/2.3 Ah | Yes; 2 x lithium AA; 3.6 V/2.3 Ah | Yes; 2 x lithium AA; 3.6 V/2.3 Ah |
Galvanic isolation |
|
|
|
|
primary/secondary | Yes | Yes | Yes | Yes |
EMC |
|
|
|
|
Compliance with line harmonic distortion limits |
|
|
|
|
| Yes | Yes | Yes | Yes |
Degree and class of protection |
|
|
|
|
Protection class | 1; with protective conductor | 1; with protective conductor | 1; with protective conductor | 1; with protective conductor |
Standards, approvals, certificates |
|
|
|
|
FM approval | Yes; Ta: 0 °C to 60 °C T4 | Yes; Ta: 0 °C to 60 °C T4 | Yes; Ta: 0 °C to 60 °C T4 | Yes; Ta: 0 °C to 60 °C T4 |
Connection method |
|
|
|
|
Connecting cables/cross sections | 3 x 1.5 mm2, solid or stranded wire with end sleeve, external diameter 3 to 9 mm | 3 x 1.5 mm2, solid or stranded wire with end sleeve, external diameter 3 to 9 mm | 3 x 1.5 mm2, solid or stranded wire with end sleeve, external diameter 3 to 9 mm | 3 x 1.5 mm2, solid or stranded wire with end sleeve, external diameter 3 to 9 mm |
Dimensions |
|
|
|
|
Width | 25 mm | 50 mm | 50 mm | 50 mm |
Height | 290 mm | 290 mm | 290 mm | 290 mm |
Depth | 217 mm | 217 mm | 217 mm | 217 mm |
Required slots | 1 | 2 | 2 | 2 |
Weight |
|
|
|
|
Weight, approx. | 760 g | 1 200 g | 1 200 g | 1 300 g |
Information material for downloading can be found in the Internet:
Код | Заказной номер | Описание | Вес (кг) | Заказать |
---|---|---|---|---|
60658 | 6AG1407-0KR02-4AA0 | siplus резервируемый блок питания ps407 10a, для тяжёлых рабочих условий, на основе блока 6es7407-0kr02-0aa0 | 1.455 | Заказать |
62367 | 6ES7490-0AA00-0AA0 | simatic s7-400, запасной съемный соединитель подключения цепей питания к ps405 4a/10a/20a | 0.049 | Заказать |
110825 | 6ES7490-0AB00-0AA0 | simatic s7-400, запасной съемный соединитель подключения цепей питания к ps407 4a/10a/20a | 0.051 | Заказать |
63265 | 6ES7971-0BA00 | simatic s7-400, буферная батарея 3.6в/1.9ачас, для ps 405 4a/10a/20a и ps 407 4a/10a/20a. для 4 а блока питания необходима одна, для 10- и 20 а блоков питания - две буферные батареи | 0.027 | Заказать |