STARTER commissioning tool производства Siemens

STARTER commissioning tool

The user-friendly STARTER commissioning tool can be used for:

  • Commissioning,
  • Optimizing and
  • Diagnostics

This software can be operated either as a standalone PC application, integrated in SIMATIC STEP 7 with TIA compatibility via Drive ES Basic, or it can be integrated into the SCOUT engineering system (for SIMOTION). The basic functions and handling are the same in both cases.

In STARTER, MICROMASTER 4 devices and the SIMATIC ET 200S FC and SIMATIC ET 200pro FC frequency converters are also supported in addition to the SINAMICS drives.

The project wizards can be used to create the drives within the structure of the project tree.

Beginners are supported by solution-based dialog guidance, whereby a standard graphics-based display maximizes clarity when setting the drive parameters.

First commissioning is guided by a wizard which makes all the basic settings in the drive. Therefore, getting a motor up and running is merely a question of setting a few of the drive parameters as part of the drive configuration process.

The individual settings required are made using graphics-based parameterization screens, which also precisely visualize the principle of operation of the drive.

Examples of individual settings that can be made include:

  • How terminals are used
  • Bus interface
  • Setpoint channel (e.g., fixed setpoints)
  • Closed-loop speed control (e.g., ramp-function generator, limits)
  • BICO interconnections
  • Diagnostics

For experts, the expert list can be used to specifically and quickly access individual parameters at any time. An individual compilation of frequently used parameters can be saved in dedicated user lists.

In addition, the following functions are available for optimization purposes:

  • Self-optimization of the controller settings (depending on drive unit)
  • Trace (for SINAMICS S120 only)

Diagnostics functions provide information about:

  • Control/status Words
  • Parameter status
  • Conditions of use
  • Communication states
Performance features
  • User-friendly: Only a small number of settings need to be made for successful first commissioning: The motor starts to rotate
  • Solution-based dialog-based user guidance simplifies commissioning.
  • Self-optimization functions reduce manual effort for optimization.

Minimum hardware and software requirements

PG or PC Pentium III min. 800 MHz (recommended > 1 GHz)

512 MB main memory (1 GB recommended)

Screen resolution 1024 × 768 pixels, 16 bit color depth

Free hard disk memory: min. 2 GB

Microsoft Windows 2000 SP4

Microsoft Windows 2003 Server SP1, SP2

Microsoft Windows XP Professional SP2, SP3

Microsoft Windows Vista Business SP1 1)

Microsoft Windows Vista Ultimate SP1 1)

Microsoft Internet Explorer V6.0 oor higher

1) DCC cannot be used. STARTER can be used on these operating systems only if it does not include the DCC option.

The SINAMICS S120/SINAMICS S150 Control Units can communicate with one another via PROFIBUS or PROFINET/Ethernet, or over a serial RS232 interface, depending on the Control Unit version (DP or PN).

The PG/PC will require a PROFIBUS communications board and a connecting cable for this purpose.

If the optional CBE20 PROFINET Communication Board is available, this can be used instead to provide an Ethernet communications link between the CU320‑2 and PG/PC.

Overview

Drive Control Chart (DCC) expands the scope of device functions by means of freely available closed-loop control, calculation and logic modules and offers a means by which technological functions can be graphically configured in the SINAMICS S120 drive system. DCC is installed as a supplementary application to the STARTER commissioning tool.

Drive Control Chart expands the facility for the simplest possible configuring of technological functions both for the Motion Control System SIMOTION as well as for the SINAMICS S120 drive system. For users, this opens up a new dimension regarding the adaptability of the systems mentioned to the specific functions of their machines. DCC has no restrictions with regard to the number of usable functions; this is only limited by the performance capability of the target platform.

The user-friendly DCC editor enables easy graphics-based configuration, allows control loop structures to be clearly represented and provides a high degree of reusability of diagrams that have already been created.

The open-loop and closed-loop control functions are defined by using multi-instance-capable blocks (Drive Control Blocks (DCBs)) from a pre-defined library (DCB library) that are selected and graphically linked with one another by dragging and dropping. Test and diagnostic functions allow the program behavior to be verified and in the case of a fault, the cause identified.

The block library encompasses a large selection of closed-loop, arithmetic and logic blocks, as well as comprehensive open-loop and closed-loop control functions.

For logically combining, evaluating and acquiring binary signals, all commonly used logic functions are available for selection (AND, XOR, on/off delay, RS flipflop, counter, etc.). A wide range of arithmetic functions, such as absolute value generation, dividers and minimum/maximum evaluation are available to monitor and evaluate numerical quantities. In addition to the closed-loop drive control, axial winder functions, closed-loop PI controllers, ramp-function generators or wobble generators can be configured simply and easily.

Closed-loop control structures can be programmed with almost no restrictions in conjunction with the SIMOTION Motion Control System. These can then be combined with other program sections to form an overall program.

Drive Control Chart for SINAMICS S120 also provides a convenient basis for resolving drive-level open-loop and closed-loop control tasks directly in the converter. This further extends the possibility of adapting SINAMICS to the particular application. Local data processing in the drive supports the implementation of modular machine concepts and results in an increase in the overall machine performance.

Minimum hardware and software requirements

See the SCOUT or STARTER engineering software, since DCC is installed in addition to these programs.

Selection and ordering data

DCC comprises the graphical configuring tool (DCC Editor) and the block library (DCB Library).

DCC is installed in addition to the SCOUT or STARTER engineering software.

The necessary engineering license for each PC (floating) for DCC is acquired at the same time the order is placed; additional runtime licenses are not required.

DCC can be ordered in two versions: The version for SIMOTION and SINAMICS applications, or the version for SINAMICS applications only.

 

Order No.

DCC-SIMOTION/-SINAMICS V2.0 SP5
for SCOUT/STARTER V4.1 SP5

(single engineeering license, with DCC data carrier)

DCC editor + DCB libraries for use on SIMOTION V4.1 SP5 and SINAMICS S120 V2.6 SP2 / V4.3 SP1

English, French, German, Italian (SIMOTION)

English, French, German, Italian, Spanish (SINAMICS)

6AU1810-1JA20-5XA0

DCC-SINAMICS V2.0 SP5
for STARTER V4.1 SP5

(single engineeering license, with DCC data carrier)

DCC editor + DCB library for use on SINAMICS S120 V2.6 SP2 / V4.3 SP1

English, French, German, Italian, Spanish

6AU1810-1HA20-5XA0


Connection

Depending on the version of the Control Unit, the Control Unit (CU) of the drive unit can communicate with the programming device (PG) or PC via a serial interface, PROFIBUS, or Ethernet/PROFINET. The following accessories are available for the particular drive system as listed in the following table.

Selection and ordering data

Drive device range

Recommended accessories for communication between the drive device and the programming device or PC via

 

RS232

Order No.

PROFIBUS

Order No.

PROFINET/Ethernet

Order No.

MICROMASTER 4

PC Inverter Connection Kit

6SE6400‑1PC00‑0AA0

SIMATIC DP plug-in cable

12 Mbaud, for PG connector, pre-assembled with 2 × 9-pin sub D connector, 3 m (9.8 ft)

6ES7901‑4BD00‑0XA0

SIMATIC ET 200S FC

SIMATIC S7 connecting cable

RS232 null-modem cable, 6 m (19.7 ft)

6ES7901‑1BF00‑0XA0

Connection to the PROFIBUS system in the plant

Connection to the PROFINET system in the plant

SIMATIC ET 200pro FC

USB interface cable

for communication with a PC

6SL3555‑0PA00‑2AA0

Connection to the PROFIBUS system in the plant

Connection to the PROFINET system in the plant

SINAMICS G110

PC Inverter Connection Kit

The scope of supply includes a 9-pin Sub-D connector, an RS232 standard cable (3 m) (9.8 ft) and the STARTER commissioning tool on DVD

6SL3255‑0AA00‑2AA1

SINAMICS G120

PC Inverter Connection Kit

For CU240 Control Units

The scope of supply includes a 9-pin Sub-D connector, an RS232 standard cable (3 m) (9.8 ft) and the STARTER commissioning tool on DVD

6SL3255‑0AA00‑2AA1

SIMATIC DP plug-in cable

12 Mbaud, for PG connector, pre-assembled with 2 × 9-pin sub D connector, 3 m (9.8 ft)

6ES7901‑4BD00‑0XA0

Standard CAT5 Ethernet cable or PROFINET cable required

 

PC Inverter Connection Kit

for CU230P-2 Control Units

The scope of supply includes a USB cable, 3m (9.8 ft), and the STARTER commissioning tool on DVD

6SL3255‑0AA00‑2AA1

SIMATIC DP plug-in cable

12 Mbaud, for PG connector, pre-assembled with 2 × 9-pin sub D connector, 3 m (9.8 ft)

6ES7901‑4BD00‑0XA0

SINAMICS G110D

USB interface cable

for communication with a PC

6SL3555‑0PA00‑2AA0

SINAMICS G120D

USB interface cable

for communication with a PC

6SL3555‑0PA00‑2AA0

Connection to the PROFIBUS system in the plant

Connection to the PROFINET system in the plant

SINAMICS S110

SIMATIC S7 connecting cable

RS232 null-modem cable, 6 m (19.7 ft)

6ES7901‑1BF00‑0XA0

PROFIBUS communications module CP 5512

PCMCIA type 2 card + adapter with 9-pin SUB-D socket,
for Windows 2000/XP Professional and PCMCIA 32

6GK1551‑2AA00

avail. soon

avail. soon

 

 

 

SIMATIC DP plug-in cable

12 Mbaud, for PG connector, pre-assembled with 2 × 9-pin sub D connector, 3 m (9.8 ft)

6ES7901‑4BD00‑0XA0

 

 

SINAMICS S120

SIMATIC S7 connecting cable

RS232 null-modem cable, 6 m (19.7 ft)

6ES7901‑1BF00‑0XA0

PROFIBUS communications module CP 5512

PCMCIA type 2 card + adapter with 9-pin SUB-D socket,
for Windows 2000/XP Professional and PCMCIA 32

6GK1551‑2AA00

Standard CAT5 Ethernet cable or PROFINET cable is required.

 

 

 

SIMATIC DP plug-in cable

12 Mbaud, for PG connector, pre-assembled with 2 × 9-pin sub D connector, 3 m (9.8 ft)

6ES7901‑4BD00‑0XA0

 

 

SINAMICS S150

SIMATIC S7 connecting cable

RS232 null-modem cable, 6 m (19.7 ft)

6ES7901‑1BF00‑0XA0

PROFIBUS communications module CP 5512

PCMCIA type 2 card + adapter with 9-pin SUB-D socket,
for Windows 2000/XP Professional and PCMCIA 32

6GK1551‑2AA00

Standard CAT5 Ethernet cable or PROFINET cable is required.

 

 

 

SIMATIC DP plug-in cable

12 Mbaud, for PG connector, pre-assembled with 2 × 9-pin sub D connector, 3 m (9.8 ft)

6ES7901‑4BD00‑0XA0

 

 

SINAMICS G130

SIMATIC S7 connecting cable

RS232 null-modem cable, 6 m (19.7 ft)

6ES7901‑1BF00‑0XA0

PROFIBUS communications module CP 5512

PCMCIA type 2 card + adapter with 9-pin SUB-D socket,
for Windows 2000/XP Professional and PCMCIA 32

6GK1551‑2AA00

Standard CAT5 Ethernet cable or PROFINET cable is required.

 

 

 

SIMATIC DP plug-in cable

12 Mbaud, for PG connector, pre-assembled with 2 × 9-pin sub D connector, 3 m (9.8 ft)

6ES7901‑4BD00‑0XA0

 

 

SINAMICS G150

SIMATIC S7 connecting cable

RS232 null-modem cable, 6 m (19.7 ft)

6ES7901‑1BF00‑0XA0

PROFIBUS communications module CP 5512

PCMCIA type 2 card + adapter with 9-pin SUB-D socket,
for Windows 2000/XP Professional and PCMCIA 32

6GK1551‑2AA00

Standard CAT5 Ethernet cable or PROFINET cable is required.

 

 

 

SIMATIC DP plug-in cable

12 Mbaud, for PG connector, pre-assembled with 2 × 9-pin sub D connector, 3 m (9.8 ft)

6ES7901‑4BD00‑0XA0

 

 


The STARTER commissioning tool is also available for update purposes on the Internet at
http://support.automation.siemens.com/WW/view/en/10804985/133100

Код Заказной номер Описание Вес (кг) Заказать
109351 6AU1810-1HA20-5XA0 sinamics инженерное п.о. dcc sinamics v2.0 sp5 полная лицензия dcc для sinamics v2.6 sp2/v4.3 sp1 опция к starter v4.1 sp5 поставка на носителе данных dvd вкл.: floating license 0.01 Заказать
109356 6AU1810-1JA20-5XA0 simotion инженерное п.о. dcc simotion v2.0 sp5 полная лицензия dcc для simotion v4.1 sp5 и для sinamics v2.5 sp1 опция для scout v4.1 sp5 и для starter v4.1 sp5 поставка на dvd включая плавающую лицензию 0.01 Заказать
63183 6ES7901-1BF00-0XA0 simatic s7, соединительный кабель (нуль-модемный кабель rs 232) для hmi-адаптера и pc/ts адаптера, длина 5m 0.27 Заказать
111161 6ES7901-4BD00-0XA0 simatic dp, соединительный кабель для подключения программатора к сети profibus-dp, до 12 мбит/с, с двумя 9-полюсными соединителями d-типа, длина 3 m 0.315 Заказать
66310 6GK1551-2AA00 simatic net, pb, cp 5512 pc-карта (cardbus, 32 бита) для подключения pg (программатора) или ноутбука к сети profibus или mpi 0.251 Заказать
66319 6GK1571-1AA00 коммуникационный процессор cp5711 usb-адаптор (usb 2.0) для подключения pg или ноутбука к profibus или mpi; 2м кабель usb в комплекте 0.3 Заказать
115339 6SE6400-1PC00-0AA0 micromaster 4 pc - набор для связи пк и преобразователя 0.7 Заказать
67586 6SL3072-0AA00-0AG0 starter утилита для ввода в эксплуатацию для sinamics и micromaster версия v4.1 sp2 dvd для windows 2000 sp3,sp4 и windows 2003 server sp1 и windows xp prof sp1, sp2, sp3 немецкий английский испанский французский и итальянский 0.03 Заказать
68021 6SL3255-0AA00-2AA1 sinamics g110 / g120 набор для связи пк и преобразователя вкл. прогр. обеспеч. по началу работы starter на cd-rom 0.4 Заказать
116255 6SL3555-0PA00-2AA0 sinamics g120d usb интерфейс cable длина 2,5 m 0.15 Заказать
;