The SMC20 Sensor Module Cabinet-Mounted is required to evaluate the encoder signals of motors without a DRIVE‑CLiQ interface. External encoders can also be connected via the SMC20.
The following encoder signals can be evaluated:
The motor temperature can also be detected using KTY84‑130 or PTC thermistors.
SMC20 Sensor Module Cabinet‑Mounted 6SL3055-0AA00-5BA3 | |
---|---|
Current requirement, max. At 24 V DC, | 0.2 A |
| 2.5 mm2 |
| 20 A |
Power loss, max. | 10 W |
Encoders which can be evaluated |
|
| 5 V DC/0.35 A |
| 500 kHz |
| 16384 times (14 bit) |
| 100 kBaud |
| 100 m (328 ft) |
PE connection | M4 screw |
Dimensions |
|
| 30 mm (1.18 in) |
| 150 mm (5.91 in) |
| 111 mm (4.37 in) |
Weight, approx. | 0.45 kg (1 lb) |
Approvals, according to | cULus |
The SMC20 Sensor Module Cabinet-Mounted features the following interfaces as standard:
The status of the SMC20 Sensor Module Cabinet-Mounted is indicated via a multi-color LED.
The SMC20 Sensor Module Cabinet-Mounted can be snapped onto a TH 35 top-hat rail according to EN 60715 (IEC 60715).
The signal cable shield is connected via the encoder system connector and can also be connected to the SMC20 Sensor Module Cabinet-Mounted via a shield connection terminal, e.g. Phoenix Contact type SK8 or Weidmüller type KLBÜ CO 1.
The SMC20 Sensor Module Cabinet-Mounted communicates with a Control Unit via DRIVE-CLiQ.
Код | Заказной номер | Заказать |
---|---|---|
115640 | 6SL3055-0AA00-5BA3 | Заказать |