Pulsers with inductive pick-up производства Siemens

Pulsers with inductive pick-up

Pulser with inductive pick-up

The pulser is used for quantity metering in conjunction with electromechanical pulse counters as a transmitter with output signals for electronic data processing.

Using the pulser, quantity measurements from volumetric meters can be converted into electrical pulses for remote transmission. The pulser is used in conjunction with a pulse amplifier or a frequency-to-current converter.

Pulser with inductive pick-up

Slot initiator

Sensor SJ 3,5-N-K37

Power supply (from SITRANS F RA110)

8 V DC, Ri approx. 1 kΩ (DIN 19234) Ci = 40 nF; Li = 160 µH

Change in current consumption on pulse

≤ 1 mA/ ≤ 3mA (DIN 19234)

Permissible line resistance between pick-up and amplifier

≤ 50 Ω (DIN 19234)

Number of pulses per revolution of the drive

10 or 100

Phase position of the channels of the double pick-up

180 ° : 180 ° ± 30 °
Electrically offset 90 ° ± 30 °

Duty factor

1 : 1 ± 17 %

Max. pulse frequency

3000 Hz

Pulse valence

Dependent on value per revolution of the drive of the respective meter

Permissible ambient temp.

-25 ... +100 °C (-13 ... +212 °F)

Degree of protection

IP43 to EN 60529 with register

 

P65 to EN 60529 with protective cover

 

This pulser has the EC-Type Examination Certificate PTB 99 ATEX 2219X.

Mounting position

Any

Weight approx.

1.2 kg (2.65 lb)

Ex approval

IIG EEx ia IIC T6


  • Electronic design
  • High pulse frequency (≤ 3000 Hz)
  • Electronic output
    • 170 mA, 24 V DC (delivering current) for electromechanical pulse counters
    • 2 mA, 24 V DC (absorbing current) for electronic processing
Pulse valence with quantity measurements

Conversion of metered quantities into electrical pulses

Measuring system for remote metering and digital data processing

The metering shaft of the volumetric meter drives a pulse disk. The vanes of the pulse disk successively enter the air gap of an inductive pick-up, thus changing the coupling between two coils. This causes a change in resistance that is converted into a pulse by the subsequent pulse amplifier, which also powers the pick-up.

The pulser operates without contacts. No measurable force is exerted on the disk. This means that the system is free from feed-backs.

Depending on the design, 10 or 100 pulses are produced for each revolution of the drive. The pulse amplifier amplifies the incoming pulses. A timing circuit prevents a continuous output pulse.

The quantitative value associated with one pulse depends on the value per revolution of the drive (pulses per liter or gallon) or on the respective volume of the measuring chamber of the drive.

Pulsers with two inductive pick-ups are available for systems for custody transfer as PTB regulations currently specify a duplicated transmission system with pulse comparison.

Pulse valence with flow measurements

Conversion of metered quantities into electrical pulses

Measuring system for flow measurement

During flow measurements, the change in resistance is converted to pulses by SITRANS F RA110. Each pulse corresponds to a given quantity of metered liquid. The number of pulses per unit in time (the frequency) is a measure of the flow rate.

SITRANS F RA110 converts the incoming NAMUR signals into load-independent direct current.

The electric pulser is available for 10 or 100 pulses per revolution. The choice depends on the smallest flow rate still to be indicated.

Pulser with inductive pick-up, dimension in mm (inch)

Pulser with inductive pick-up, connection diagram for clockwise rotation; pick-up l to terminals 3 and 4 for counter-clockwise rotation

Код Заказной номер Описание Вес (кг) Заказать
72413 7MV1105-1AA00 источник импульсов с индуктивным источником сигнала (одинарный ), 10 импульсов на оборот 1.2 Заказать
118958 7MV1105-2AA00 источник импульсов с индуктивным источником сигнала (одинарный), 100 импульсов на оборот 1.2 Заказать
118959 7MV1105-3AA01 источник импульсов с индуктивным источником сигнала (двойной) ,10 импульсов на оборот 1.2 Заказать
118960 7MV1105-4AA01 источник импульсов с индуктивным источником сигнала (двойной) 100 импульсов на оборот 1.2 Заказать
79547 C73000-B5174-C25 instructions, german/english for pulser 7mv1105 0.1 Заказать
;