Suitable for non-corrosive and corrosive gases, vapors and liquids; permissible operating temperature -10 to +400 °C.
Orifice plate with annular chambers consisting of two support rings with replaceable orifice disk form A or B (see types of primary differential pressure devices in "Technical description", "Function"); flanged between inlet and outlet pipe sections with lengths according to DIN 19205.
(For the dimensions of the following tapping sockets, see page 4/xxx)
For length of tapping sockets for all metering pipe L = 120 mm and position of tapping socket, see "Technical Description" and "Function".
DN | PN | a | L | k | Pipe1) Da x s | Weight kg |
---|---|---|---|---|---|---|
10 | 10 and 16 | 400 | 218 | 320 | 16 x 3 | 4,5 |
25 and 40 | 320 | 5 | ||||
63 and 100 | 295 | 6,5 | ||||
15 | 10 and 16 | 550 | 368 | 325 | 20 x 2.5 | 5 |
25 and 40 | 325 | 5,5 | ||||
63 and 100 | 300 | 7,5 | ||||
20 | 10 and 16 | 700 | 488 | 335 | 25 x 2.5 | 6,5 |
25 and 40 | 7 | |||||
25 | 10 and 16 | 900 | 638 | 310 | 30 x 2.5 | 8 |
25 and 40 | 9 | |||||
63 and 100 | 14 | |||||
32 | 10 and 16 | 1100 | 788 | 320 | 38 x 3 | 11,5 |
25 and 40 | 12,5 | |||||
40 | 10 and 16 | 1300 | 988 | 330 | 48, 3 x 3.6 or 50 x 5 | 13 |
25 and 40 | 330 | 15 | ||||
63 and 100 | 335 | 25 | ||||
50 | 10 and 16 | 1500 | 1188 | 340 | 60 x 5 | 20 |
25 and 40 | 340 | 22 | ||||
63 | 345 | 34 | ||||
100 | 345 | 34 |
Metering pipes with orifice plates and annular chambers for installation between EN flanges to EN 1092.1, dimensions in mm and weights
1) The stated pipe dimensions may vary, depending on availability. The pipe dimensions used can be found in the calculation for primary differential pressure devices and/or in the order confirmation.
ASME | PN | a | L | k | Pipe1) Da x s | Weight kg |
---|---|---|---|---|---|---|
½ inch | Class 150 | 550 | 368 | 297 | 20 x 2.5 | 5 |
Class 300 | 307 | 5,5 | ||||
Class 600 | 307 | 7,5 | ||||
¾ inch | Class 150 | 700 | 488 | 297 | 25 x 2.5 | 6,5 |
Class 300 | 307 | 7 | ||||
Class 600 | 307 | 8 | ||||
1 inch | Class 150 | 900 | 638 | 307 | 30 x 2.5 | 8 |
Class 300 | 313 | 9 | ||||
Class 600 | 313 | 14 | ||||
1¼ inch | Class 150 | 1100 | 788 | 316 | 38 x 3 | 11,5 |
Class 300 | 322 | 12,5 | ||||
Class 600 | 322 | 14 | ||||
1½ inch | Class 150 | 1300 | 988 | 326 | 48, 3 x 3.6 or 50 x 5 | 13 |
Class 300 | 335 | 15 | ||||
Class 600 | 335 | 25 | ||||
2 inch | Class 150 | 1500 | 1188 | 345 | 60 x 5 | 20 |
Class 300 | 371 | 22 | ||||
Class 600 | 351 | 34 |
Metering pipes with orifice plates and annular chambers for installation between ASME flanges to ASME B 16.5, dimensions in mm and weights
1) The stated pipe dimensions may vary, depending on availability. The pipe dimensions used can be found in the calculation for primary differential pressure devices and/or in the order confirmation.
Код | Заказной номер | Заказать |
---|---|---|
71149 | 7ME1310-.....-.... | Заказать |