Metering pipes w. orifice plate+annular chambers производства Siemens

Metering pipes w. orifice plate+annular chambers

Suitable for non-corrosive and corrosive gases, vapors and liquids; permissible operating temperature -10 to +400 °C.

Orifice plate with annular chambers consisting of two support rings with replaceable orifice disk form A or B (see types of primary differential pressure devices in "Technical description", "Function"); flanged between inlet and outlet pipe sections with lengths according to DIN 19205.

Nominal diameters
  • EN: DN 10 to DN 50
  • ASME: ½ inch to 2 inch
Nominal pressure
  • EN: PN 10 to PN 100
  • ASME: class 150 to 600
Sealing face of the end flanges
  • Plane, sealing face turned, N10/N12 to DIN ISO 1302
  • Plane, sealing face turned, N8 to DIN ISO 1302
  • Plane, RF (raised faced) for versions to ASME
Tapping sockets

(For the dimensions of the following tapping sockets, see page 4/xxx)

  • With connection thread G½ DIN ISO 228/1, connection dimensions to DIN 19207 form V
  • With threaded connection ½-14 NPT male, for version to ASME
  • With Ø 12 mm pipe connection for pipe union with ferrule
  • With welding connection, Ø 21.3 mm

For length of tapping sockets for all metering pipe L = 120 mm and position of tapping socket, see "Technical Description" and "Function".

DN

PN

a

L

k

Pipe1)

Da x s

Weight

kg

10

10 and 16

400

218

320

16 x 3

4,5

25 and 40

320

5

63 and 100

295

6,5

15

10 and 16

550

368

325

20 x 2.5

5

25 and 40

325

5,5

63 and 100

300

7,5

20

10 and 16

700

488

335

25 x 2.5

6,5

25 and 40

7

25

10 and 16

900

638

310

30 x 2.5

8

25 and 40

9

63 and 100

14

32

10 and 16

1100

788

320

38 x 3

11,5

25 and 40

12,5

40

10 and 16

1300

988

330

48, 3 x 3.6 or 50 x 5

13

25 and 40

330

15

63 and 100

335

25

50

10 and 16

1500

1188

340

60 x 5

20

25 and 40

340

22

63

345

34

100

345

34


Metering pipes with orifice plates and annular chambers for installation between EN flanges to EN 1092.1, dimensions in mm and weights

1) The stated pipe dimensions may vary, depending on availability. The pipe dimensions used can be found in the calculation for primary differential pressure devices and/or in the order confirmation.

ASME

PN

a

L

k

Pipe1)

Da x s

Weight

kg

½ inch

Class 150

550

368

297

20 x 2.5

5

Class 300

307

5,5

Class 600

307

7,5

¾ inch

Class 150

700

488

297

25 x 2.5

6,5

Class 300

307

7

Class 600

307

8

1 inch

Class 150

900

638

307

30 x 2.5

8

Class 300

313

9

Class 600

313

14

1¼ inch

Class 150

1100

788

316

38 x 3

11,5

Class 300

322

12,5

Class 600

322

14

1½ inch

Class 150

1300

988

326

48, 3 x 3.6 or 50 x 5

13

Class 300

335

15

Class 600

335

25

2 inch

Class 150

1500

1188

345

60 x 5

20

Class 300

371

22

Class 600

351

34


Metering pipes with orifice plates and annular chambers for installation between ASME flanges to ASME B 16.5, dimensions in mm and weights

1) The stated pipe dimensions may vary, depending on availability. The pipe dimensions used can be found in the calculation for primary differential pressure devices and/or in the order confirmation.

  • Описание : sitrans f o - delta p, metering pipe for mounting between flanges, orifice plate with annular chambers mounted between flanges
  • Вес (кг) : 0.1
Код Заказной номер Заказать
71149 7ME1310-.....-.... Заказать
;