SIPLUS SCALANCE X-300 managed производства Siemens

SIPLUS SCALANCE X-300 managed

  • The SCALANCE X-300 product line consists of compact Industrial Ethernet switches for establishing electrical and/or optical line, ring and star topologies at 10/100/1000 Mbit/s
  • Three integral electrical and/or optical Gigabit Ethernet interfaces (10/100/1000 Mbit/s) and seven electrical Fast Ethernet interfaces (10/100 Mbit/s) for interconnecting several switches to establish Gigabit or Fast Ethernet rings or to connect Industrial Ethernet nodes
  • High-speed media redundancy through integral redundancy manager both for Gigabit Ethernet (SCALANCE X-300, SCALANCE X-400) and Fast Ethernet (SCALANCE X-300 switches in the ring in combination with SCALANCE X-200 switches or OSM/ESM)
  • Switches from the SCALANCE X-300 product line support numerous IT standard and thus permit seamless integration of automation networks into existing corporate networks. Virtual local area networks (VLANs) can be constructed
  • The support of standardized redundancy procedures (Rapid Spanning Tree Protocol) permits redundant integration into higher-level enterprise networks
  • By learning the multicast sources and destinations (IGMP Snooping and IGMP Querier (Internet Group Management Protocol)), SCALANCE X-300 switches can also filter multicast data traffic and thus limit the load on the network.
  • The ports can be configured for terminal devices that support authentication in accordance with IEEE 802.1x. Authentication is done via a RADIUS server which has to be configured accordingly and must be able to be reached via the network.
  • Rugged metal enclosure in S7-300 format for mounting on standard rail, S7-300 standard mounting rail or for direct wall mounting in various positions
  • Compact, space-saving design for installation in control cabinet
  • Rugged, industry-standard station connections with PROFINET-compatible RJ45 connectors that offer additional strain relief and bending strain relief thanks to latching on the housing
  • Redundant power supply for protection against power failure
  • Diagnostics on the device by means of LEDs (power, link status, data traffic, fault, redundancy manager)
  • Fault signaling contact, can be easily set by means of the SELECT/SET pushbutton for simple display of faults
  • The devices feature PROFINET diagnostics, SNMP access, integrated web server and automatic e-mail sending function for remote diagnosis and signaling via the network.

Note:

SIPLUS extreme products are based on Siemens Industry standard products. The contents listed here were taken from the respective standard products. SIPLUS extreme-specific information was added.

 

SIPLUS SCALANCE X308-2

Order number

6AG1 308-2FL00-4AA3

Order No. based on

6GK5 308-2FL00-2AA3

Ambient temperature range

-10 ... +60 °C

Conformal coating

Coating of the printed circuit boards and the electronic components

Technical data

The technical data of the standard product applies except for the environmental conditions.

Ambient conditions

Relative humidity

5 ... 100 %
Condensation permissible

Biologically active substances

Conformity with EN 60721‑3‑3, Class 3B2 mold and fungal spores (except fauna)

Chemically active substances

Conformity with EN 60721‑3‑3, Class 3C4 incl. salt mist and ISA–S71.04 severity level G1; G2; G3; GX 1)2)

Mechanically active substances

Conformity with EN 60721‑3‑3, Class 3S4 including conductive sand, dust 2)

Air pressure (depending on the highest positive temperature range specified)

1080 ... 795 hPa (-1000 ... +2000 m)
see ambient temperature range

795 ... 658 hPa (+2000 ... +3500 m)
derating 10 K

658 ... 540 hPa (+3500 ... +5000 m)
derating 20 K


1) ISA-S71.04 severity level GX: Long-term load: SO2 < 4.8 ppm; H2S < 9.9 ppm; Cl < 0.2 ppm; HCl < 0.66 ppm; HF < 0.12 ppm; NH < 49 ppm; O3 < 0.1 ppm; NOX < 5.2 ppm
Limit value (max. 30 min/d): SO2 < 17.8 ppm; H2S < 49.7 ppm; Cl < 1.0 ppm; HCl < 3.3 ppm; HF < 2.4 ppm; NH < 247 ppm; O3 < 1.0 ppm; NOX < 10.4 ppm

2) The supplied plug covers must remain in place over the unused interface when operated in atmospheres containing corrosive gases!

The technical documentation on SIPLUS can be found here:
http://www.siemens.de/siplus-extreme

SCALANCE X-300 products enable the establishment of switched networks both at the field level and at the control level where high data transfer rates are required in addition to high network availability and extensive diagnostics facilities. The switches are designed in degree of protection IP30 for installation in control cabinets.

The main area of application is found in high-performance plant networks with interfaces to the corporate network.

The X308-2M TS is suitable for use in railway applications due to its specification according to EN 50155.

Product versions

Switches with Fast Ethernet and Gigabit Ethernet ports

Electrical star topology with SCALANCE X310

SCALANCE X310, SCALANCE X308-2, SCALANCE X308-2LD,
SCALANCE X308-2LH, SCALANCE X308-2LH+,
SCALANCE X307-3, SCALANCE X307-3LD

  • For configuring electrical Industrial Ethernet line, star or ring structures
    • SCALANCE X310;
      3 x 10/100/1000 Mbit/s RJ45 ports, electrical
      7 x 10/100 Mbit/s RJ45 ports, electrical
    • SCALANCE X308-2;
      1 x 10/100/1000 Mbit/s RJ45 ports, electrical
      7 x 10/100 Mbit/s RJ45 ports, electrical
      2 x 1000 Mbit/s SC ports, optical, for glass FOC (multimode) up to 750 m
    • SCALANCE X307-3;
      7 x 10/100 Mbit/s RJ45 ports, electrical
      3 x 1000 Mbit/s SC ports, optical, for glass FOC (multimode) up to 750 m
    • SCALANCE X308-2LD;
      1 x 10/100/1000 Mbit/s RJ45 ports, electrical
      7 x 10/100 Mbit/s RJ45 ports, electrical
      2 x 1000 Mbit/s SC ports, optical, for glass FOC (singlemode) up to 10 km
    • SCALANCE X307-3LD;
      7 x 10/100 Mbit/s RJ45 ports, electrical
      3 x 1000 Mbit/s SC ports, optical, for glass FOC (singlemode) up to 10 km
    • SCALANCE X308-2LH;
      1 x 10/100/1000 Mbit/s RJ45 ports, electrical
      7 x 10/100 Mbit/s RJ45 ports, electrical
      2 x 1000 Mbit/s SC ports, optical, for glass FOC (singlemode) up to 40 km
    • SCALANCE X308-2LH+;
      1 x 10/100/1000 Mbit/s RJ45 ports, electrical
      7 x 10/100 Mbit/s RJ45 ports, electrical
      2 x 1000 Mbit/s SC ports, optical, for glass FOC (singlemode) up to 70 km
  • The RJ45 ports are designed to be industry-standard with additional holding collars for connection of the IE FC RJ45 Plug 180

Connection of control cabinets with SCALANCE X308-2 in an optical gigabit ring

Fast Ethernet switches

SCALANCE X310FE
SCALANCE X304-2FE
SCALANCE X306-1LD FE
SCALANCE X320-1FE
SCALANCE X320-3 LD FE

  • For configuring electrical and/or optical Industrial Ethernet line, star or ring structures
    • SCALANCE X310FE;
      10 x 10/100 Mbit/s RJ45 ports, electrical
    • SCALANCE X304-2FE;
      4 x 10/100 Mbit/s RJ45 ports, electrical
      2 x 100 Mbit/s SC ports, optical, for glass FOC (multimode) up to 5 km
    • SCALANCE X306-1LD FE;
      6 x 10/100 Mbit/s RJ45 ports, electrical
      1 x 100 Mbit/s SC port, optical, for glass FOC (singlemode) up to 26 km
    • SCALANCE X320-1FE;
      20 x 10/100 Mbit/s RJ45 ports, electrical
      1 x 100 Mbit/s SC port, optical, for glass FOC (multimode) up to 5 km
    • SCALANCE X320-3LD FE;
      20 x 10/100 Mbit/s RJ45 ports, electrical
      1 x 100 Mbit/s SC port, optical, for glass FOC (multimode) up to 5 km
      2 x 100 Mbit/s SC ports, optical, for glass FOC (singlemode), up to 26 km
  • The RJ45 ports are designed to be industry-standard with additional holding collars for connection of the IE FC RJ45 Plug 180

Redundant ring topology with SCALANCE X for wind farms

Full Gigabit switches

SCALANCE X308-2M
SCALANCE X308-2M TS

  • For setting up optical line, ring or star network structures with
    • Four integrated electrical Gigabit Ethernet ports and
    • Four modular slots for equipping with any 2-port media modules
      (see "Media modules for SCALANCE X-300")
  • Star hubs in the plant bus
    (redundant connection possible)
  • SCALANCE X308-2M;
    4 x 10/100/1000 Mbit/s RJ45 ports, electrical
    2 x free module slots for 4 x 10/100/1000 Mbit/s media modules (electrical or optical)
  • SCALANCE X308-2M TS (TS = Transportation Systems);
    4 x 10/100/1000 Mbit/s RJ45 ports, electrical
    2 x free module slots for 4 x 10/100/1000 Mbit/s media modules (electrical or optical)
    is suitable for use in railway applications due to its specification according to EN 50155
  • High availability of the network thanks to:
    • Redundant power supply
    • Redundant network structures based on fiber-optic or twisted pair cables
      (redundancy manager, standby function, and RSTP are integrated)
    • Easy device replacement by means of plug-in C-PLUG swap medium
    • Very fast reconfiguration of the network in the event of a fault
  • Lower susceptibility to failure and higher availability of the plant networking due to latching of the RJ45 FastConnect connectors in the sleeve of the RJ45 ports
  • Protection of investment due to integration into existing network management systems by means of standardized SNMP access
  • Time savings during engineering, commissioning and in the operating phase of a plant by using the configuration and diagnostics integrated in STEP 7
  • Simple adaptation to different network topologies, and reduction in stock keeping costs through flexibility of the partially modular versions

The SCALANCE X-300 Industrial Ethernet switches with rugged metal housing are optimized for mounting on a standard DIN rail and the S7-300 rail. Direct wall mounting in various positions is also possible. Thanks to the S7-300 housing dimensions, the devices are suitable for integration into an automation solution with S7-300 components.

The switches have:

  • a 4-pin terminal block for connecting the redundant power supply (2 x 24 V DC)
  • Row of LEDs for indicating the status information (power, link status, data traffic, fault, redundancy manager, standby manager)
  • A 2-pin terminal block for connecting the isolated signaling contact
  • SELECT/SET key for on-site configuration of the signaling contact
  • Slot for optional C-PLUG swap medium on the rear of the device for easy replacement in the event of a fault

The SCALANCE X-300 switches are available with the following port types:

  • 10/100BaseTX, RJ45 connection;
    RJ45 socket, automatic detection of the data rate (10 or 100 Mbit/s), with Autosensing and Autocrossover function for the connection of IE FC cables via IE FC RJ45 Plug 180 to 100 m.
  • 10/100/1000BaseTX, RJ45 connection;
    RJ45 socket, automatic detection of the data rate (10 or 100 or 1000 Mbit/s), with Autosensing and Autocrossover function for the connection of
    • IE FC cables 2x2 for 100 Mbit/s via IE FC RJ45 Plug 180 up to 100 m
    • IE FC cables 4x2 for 1000 Mbit/s via TP Cord and IE FC RJ45 Modular Outlet up to 100 m
    • IE FC cables 4x2 for 1000 Mbit/s via IE FC RJ45 Plug 4x2 up to 100 m
  • 1000BaseSX, SC connections;
    SC ports for direct connection to the Industrial Ethernet glass fiber-optic cable up to 750 m (multimode)
  • 1000BaseSX, SC connections;
    SC ports for direct connection to the Industrial Ethernet glass fiber-optic cable up to 10 km (singlemode)
  • 1000BaseLX, SC connections;
    SC ports for direct connection to the Industrial Ethernet glass fiber-optic cable up to 40 km (singlemode)
  • 1000BaseLX, SC connections;
    SC ports for direct connection to the Industrial Ethernet glass fiber-optic cable up to 70 km (singlemode)
  • Increase of the network performance;
    by filtering the data traffic on the basis of the Ethernet (MAC) address of the data terminals, data traffic remains local; only data intended for users of another subnetwork are forwarded by the switch.
  • Simple network configuration and expansion;
    the switch saves the data received at the ports and forwards them independently to the destination address. Collision detection (CSMA/CD method) does not restrict the expansion of the network beyond the port.
  • Limiting of error spreading to the associated subnetwork;
    the SCALANCE X-300 switches only pass on data with a valid checksum (CRC).
  • Integration of existing subnetworks with 10 Mbit/s into Fast Ethernet networks with 100 Mbit/s;
    at the twisted-pair ports, the SCALANCE X-300 switch automatically recognizes the conductor pairs for transmission and reception (Autocrossover), the data transfer rate of 10 or 100 or 1000 Mbit/s, as well as full-duplex and half-duplex mode (Autonegotiation).
  • High-performance connection of SCALANCE X-300 switches with 1 Gbit/s;
    SCALANCE X-300 switches have Gigabit Ethernet ports for connecting the switches to each other or with other Gigabit-Ethernet-enabled components (e.g. SCALANCE X-400, X-500)
  • Integrated redundancy manager for constructing Fast Ethernet and Gigabit Ethernet ring topologies with high-speed media redundancy.
  • High-speed standby redundancy;
    several network segments such as rings can be interconnected redundantly with SCALANCE X-300 over the integrated standby function. Two X-300 switches are configured in a ring as a master and slave over two links to the other ring. The redundant connection can be made at 1000 Mbit/s.
  • Redundant interfacing to higher-level networks;
    SCALANCE X-300 switches support the standardized redundancy procedures Spanning Tree Protocol (STP) and Rapid Spanning Tree Protocol (RSTP). This enables a subnetwork to be connected redundantly to a higher-level network with reduced requirements for the reconfiguration time (in the order of seconds).
  • Support of virtual networks (VLAN);
    for structuring Industrial Ethernet networks with a fast growing number of users, a physically existing network can be divided into several virtual networks.
  • Load limiting when multicast protocols (e.g. video transmission) are used;
    through learning the multicast sources and targets (IGMP Snooping, IGMP Querier), SCALANCE X-300 switches can also filter multicast data traffic and therefore limit the load in the network.
  • Configuration of the ports for terminals that support authentication in accordance to IEEE 802.1x. Authentication is done via a RADIUS server which has to be configured accordingly and must be able to be reached via the network.
  • Support of the DHCP Option 82, 66, 67 (Dynamic Host Configuration Protocol);
    this facilitates the IP address assignment of a terminal depending on the connected switch port. The IP address is assigned via a DHCP Server, which has to be configured accordingly and must be able to be reached via the network.
  • Support from the Access Control List (ACL);
    if this function is activated for one port, the switch forwards the message frames received to this port if its source address is present in the address table. All connected nodes can be automatically entered in the ACL.
  • Syslog;
    Syslog according to RFC 3164 is used in the IP network for transmitting short, unencrypted text messages via UDP. This requires the use of a Syslog server that must be configured appropriately and must be accessible via the network.
  • Time synchronization;
    diagnostic messages (log table entries, e-mails) are time-stamped. The local time is standardized throughout the network by means of synchronization with a SICLOCK or SNTP time transmitter, thereby simplifying the assignment of diagnostic messages to several devices.
  • Fast replacement of devices in event of failure, by means of the C-PLUG switching medium

Network topology and network configuration

The SCALANCE X-300 Industrial Ethernet switches with degree of protection IP30 are typically accommodated in a control cabinet along with the nodes to be connected. The can be mixed electrically and optically in star, line and ring topologies.

The following network structures and combinations of structures can be implemented:

  • Fast Ethernet and Gigabit Ethernet rings with fast media redundancy;
    to increase network availability, as many as 50 X-200, X-300, X-400 or X-500 switches can be cascaded in line can be connected into a ring
  • Several rings can be redundantly linked through the standby function
  • In addition, SCALANCE X-300 supports redundant connection of the ring structure to the corporate network with a rapid spanning tree.
  • Star topology with SCALANCE X-300 switches:
    The SCALANCE X-300 switch represents a star point which can interconnect several nodes or subnets electrically or optically.

When configuring the network, it is necessary to observe the following boundary conditions:

  • Maximum line length between two modules for multi-mode fiber-optic conductors:
    • 750 m at 1 Gbit/s
    • 5 km at 100 Mbit/s
  • Maximum line length between two modules for single-mode fiber-optic conductors:
    • 10 to 70 km at 1 Gbit/s
    • 26 km at 100 Mbit/s
  • Maximum cable length of the TP cable between two SCALANCE X switches:
    • Max. 100 m with IE FC cable 2x2 and IE FC RJ45 Plug 180
    • Max. 100 m at 1 Gbit/s with IE FC Standard Cable 4x2 (90 m), IE FC RJ45 Modular Outlet and patch cable (10 m)
    • Max. 10 m using patches with TP cord

Commissioning and diagnosis

Setting options on the device itself:

  • Redundancy manager RM;
    to establish a ring, a SCALANCE X-300 is switched to RM mode. The Gigabit ports (electrical or optical) are preferably used as ring ports.
  • Signal mask;
    the signal mask is set to the current status of the SCALANCE X-300 (setpoint) by pushbutton operation. The signal mask defines which ports and which power supplies are to be monitored. The signaling contact only reports an error when a monitored port or a monitored feeder fails (deviation of setpoint/actual status).
  • IP address;
    the IP address is assigned via DHCP (Dynamic Host Configuration Protocol). If there is no corresponding server in the network, the IP address can be assigned using an enclosed software tool.

Diagnostic options on site:

  • The following status information is displayed by LEDs on site:
    • Port status
    • Port mode (10/100/1000 Mbit/s, full/half-duplex)
    • Status of the two power supplies
    • Signaling contact status
    • Signal mask (setpoint status)
    • RM mode
    • Standby mode
  • The status of the signaling contact is routed externally by means of floating relay contacts. This enables, for example, the module to be monitored via an input module from a controller.
  • Monitoring via the Industrial Ethernet network;
    the following possibilities are available:
    • Remote via standard browser (Web-based management):
      Selection of SCALANCE X-300 switches via the network from a PC with browser
    • Remote via SNMP V1, V2c, V3:
      Secure integration of SCALANCE X-300 switches via the network into a network management system, e.g. SINEMA Server
    • Remote via PROFINET IO diagnostics:
      PROFINET diagnostic alarms from SCALANCE X-300 switches can be displayed using the relevant SIMATIC engineering tools and they can also be processed in the controller. The engineering outlay for the PLC and HMI have been drastically reduced due to the complete integration in the SIMATIC concept for system error messages.

Network management

The network management provides the following functions:

  • Password-protected dial-up for "Administrator" (read and write authorization) and "User" (read only)
  • Read-out of version and status information
  • Setting the signal and standby mask and address information
  • Fixed parameterization of the ports (data rates, half/full duplex)
  • Setting parameters of the VLANs and multicast services
  • Parameterization of the standby connections for a redundant ring link
  • Setting of Rapid Spanning Tree parameters
  • Parameterization of the web management services
  • Security
    • Ports can be connected or disconnected
    • Authentication in accordance with IEEE 802.1x
    • Support from Access Control List (ACL)
  • Parameterization of user administration of SNMP V1, V2c, V3
  • Output of statistics information
  • Diagnosis of data traffic by means of a parameterizable mirror port with a standard commercial network analyzer
  • Loading of new firmware versions or of the configuration data via the network by a TFTP server or directly via HTTP/HTTPS using a Web browser
  • Saving the configuration data or log table via the network on a TFTP server

If faults occur in the network, the SCALANCE X-300 switch can independently send error messages (traps) to a network management system or also e-mails to a predefined network administrator.

Remote monitoring (RMON) provides the following functions:
The SCALANCE X-300 switch can collect statistics information according to the RMON groups 1 through 4. These include, for example, fault statistics that are kept for each port. This information can be read out through web-based management in the statistics sub-area.

Order No.

6GK5 304-2BD00-2AA3

6GK5 306-1BF00-2AA3

6GK5 307-3BL00-2AA3

6GK5 307-3BM00-2AA3

Product type designation

SCALANCE X304-2FE

SCALANCE X306-1LD FE

SCALANCE X307-3

SCALANCE X307-3LD

Transmission rate

 

 

 

 

Transfer rate 1

10 Mbit/s

10 Mbit/s

10 Mbit/s

10 Mbit/s

Transfer rate 2

100 Mbit/s

100 Mbit/s

100 Mbit/s

100 Mbit/s

Transfer rate 3

-

-

1 000 Mbit/s

1 000 Mbit/s

Interfaces

 

 

 

 

Number of electrical/optical connections for network components or terminal equipment maximum

6

7

10

10

Number of electrical connections

 

 

 

 

  • for network components and terminal equipment

4

6

7

7

  • for operator console

-

-

-

-

  • for alarm contact

1

1

1

1

  • for media module

-

-

-

-

  • for power supply

1

1

1

1

  • for redundant power supply

2

2

2

2

Design of electrical connection

 

 

 

 

  • for network components and terminal equipment

RJ45 port

RJ45 port

RJ45 port

RJ45 port

  • for operator console

-

-

-

-

  • for signaling contact

2-pole terminal block

2-pole terminal block

2-pole terminal block

2-pole terminal block

  • for power supply

4-pole terminal block

4-pole terminal block

4-pole terminal block

4-pole terminal block

Number of optical interfaces for optical waveguide

 

 

 

 

  • at 100 Mbit/s

2

1

-

-

  • at 1000 Mbit/s

-

-

3

3

Design of optical interface for optical waveguide

 

 

 

 

  • at 100 Mbit/s

SC port (multimode up to 5 km)

SC port (singlemode up to 26 km)

-

-

  • at 1000 Mbit/s

-

-

SC port (multimode up to 0.75 km)

SC port (singlemode up to 10 km)

Connectable optical power relative to 1 mW

 

 

 

 

  • of the transmitter output

-19 … -14 dB

-15 … -8 dB

-9.5 … -4 dB

-9.5 … -3 dB

  • of the receiver input maximum

-3 dB

-3 dB

-3 dB

-3 dB

Optical sensitivity relative to 1 mW of the receiver input minimum

-32 dB

-34 dB

-17 dB

-21 dB

Attenuation of fiber-optic cable transmission link minimum necessary

0 dB

0 dB

0 dB

0 dB

Range at the optical interface depending on the optical fiber used

0 … 5 km

0 … 26 km

0 … 0.75 km

0 … 10 km

design of the removable storage C-PLUG

Yes

Yes

Yes

Yes

Inputs/outputs

 

 

 

 

Operating voltage of signaling contacts at AC rated value

-

-

-

-

Operating current of signaling contacts at AC maximum

-

-

-

-

Operating voltage of signaling contacts at DC rated value

24 V

24 V

24 V

24 V

Operating current of signaling contacts at DC maximum

0.1 A

0,1 A

0.1 A

0.1 A

Supply voltage, current consumption, power loss

 

 

 

 

Type of supply voltage redundant power supply unit

No

No

No

No

Type of voltage of supply voltage

DC

DC

DC

DC

Supply voltage external

24 V

24 V

24 V

24 V

  • minimum

18 V

18 V

18 V

18 V

  • maximum

32 V

32 V

32 V

32 V

Product component fusing at power supply input

Yes

Yes

Yes

Yes

Type of fusing at input for supply voltage

 

 

 

 

Consumed current maximum

0.26 A

0.2 A

0.4 A

0.4 A

Active power loss

 

 

 

 

  • at 24 V for DC

6.2 W

4.8 W

9.6 W

9.6 W

  • at 230 V AC

-

-

-

-

Permitted ambient conditions

 

 

 

 

Ambient temperature

 

 

 

 

  • during operating

-40 … +60 °C

-40 … +60 °C

-10 … +60 °C

-40 … +60 °C

  • during storage

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

  • during transport

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

  • Comment

-

-

-

-

Relative humidity at 25 °C without condensation during operating maximum

95 %

95 %

95 %

95 %

Ambient condition for (standard) operation mode

-

-

-

-

Protection class IP

IP30

IP30

IP30

IP30

Design, dimensions and weight

 

 

 

 

Design

Compact

Compact

Compact

Compact

Width

60 mm

60 mm

120 mm

120 mm

Height

125 mm

125 mm

125 mm

125 mm

Depth

123 mm

123 mm

123 mm

123 mm

Net weight

0.7 kg

0.7 kg

1.4 kg

1.4 kg

Type of mounting

 

 

 

 

  • Installation 19 inch

No

No

No

No

  • 35 mm DIN rail mounting

Yes

Yes

Yes

Yes

  • wall mounting

Yes

Yes

Yes

Yes

  • S7-300 rail mounting

Yes

Yes

Yes

Yes

Type of mounting

When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted

When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted

When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted

When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted

Product properties, functions, componentsgeneral

 

 

 

 

Cascading in the case of a redundant ring at reconfiguration time of <'~0.3'~s

50

50

50

50

Cascading in cases of star structuring

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Product functionsmanagement, configuration

 

 

 

 

Product function

 

 

 

 

  • CLI

Yes

Yes

Yes

Yes

  • web-based management

Yes

Yes

Yes

Yes

  • MIB support

Yes

Yes

Yes

Yes

  • TRAPs via email

Yes

Yes

Yes

Yes

  • Configuration with STEP 7

Yes

Yes

Yes

Yes

  • RMON

Yes

Yes

Yes

Yes

  • SMTP server

Yes

Yes

Yes

Yes

  • Port mirroring

Yes

Yes

Yes

Yes

  • CoS

Yes

Yes

Yes

Yes

  • for IRT PROFINET IO switch

-

-

-

-

  • PROFINET IO diagnosis

Yes

Yes

Yes

Yes

  • switch-managed

Yes

Yes

Yes

Yes

Protocol is supported

 

 

 

 

  • Telnet

Yes

Yes

Yes

Yes

  • HTTP

Yes

Yes

Yes

Yes

  • HTTPS

Yes

Yes

Yes

Yes

  • TFTP

Yes

Yes

Yes

Yes

  • FTP

Yes

Yes

Yes

Yes

  • BOOTP

Yes

Yes

Yes

Yes

  • SNMP v1

Yes

Yes

Yes

Yes

  • SNMP v2

Yes

Yes

Yes

Yes

  • SNMP v3

Yes

Yes

Yes

Yes

  • IGMP (snooping/querier)

Yes

Yes

Yes

Yes

  • GMRP

Yes

Yes

Yes

Yes

  • DCP

Yes

Yes

Yes

Yes

  • LLDP

Yes

Yes

Yes

Yes

Identification & maintenance

 

 

 

 

  • I&M0 - device-specific information

Yes

Yes

Yes

Yes

  • I&M1 - plant identification/location name

Yes

Yes

Yes

Yes

Product functionsDiagnosis

 

 

 

 

Product function

 

 

 

 

  • Port diagnostics

Yes

Yes

Yes

Yes

  • Statistics Packet Size

Yes

Yes

Yes

Yes

  • Statistics packet type

Yes

Yes

Yes

Yes

  • Error statistics

Yes

Yes

Yes

Yes

  • SysLog

Yes

Yes

Yes

Yes

Product functionsVLAN

 

 

 

 

Product function

 

 

 

 

  • VLAN - port based

Yes

Yes

Yes

Yes

  • VLAN dynamic

Yes

Yes

Yes

Yes

Number of VLANs maximum

255

255

255

255

Number of VLANs - dynamic maximum

255

255

255

255

Protocol is supported GVRP

Yes

Yes

Yes

Yes

Product functionsDHCP

 

 

 

 

Product function

 

 

 

 

  • DHCP client

Yes

Yes

Yes

Yes

  • DHCP Option 82

Yes

Yes

Yes

Yes

  • DHCP Option 66

Yes

Yes

Yes

Yes

  • DHCP Option 67

Yes

Yes

Yes

Yes

Product functionsRedundancy

 

 

 

 

Product function

 

 

 

 

  • Ring redundancy

Yes

Yes

Yes

Yes

  • Redundancy manager

Yes

Yes

Yes

Yes

  • Standby redundancy

Yes

Yes

Yes

Yes

  • HSR redundancy protocol

Yes

Yes

Yes

Yes

  • MRP redundancy protocol

Yes

Yes

Yes

Yes

  • redundancy procedure STP

Yes

Yes

Yes

Yes

  • RSTP redundancy protocol

Yes

Yes

Yes

Yes

  • Passive listening

Yes

Yes

Yes

Yes

Protocol is supported

 

 

 

 

  • STP/RSTP

Yes

Yes

Yes

Yes

  • STP

Yes

Yes

Yes

Yes

  • RSTP

Yes

Yes

Yes

Yes

  • RSTP big network support

Yes

Yes

Yes

Yes

  • LACP

Yes

Yes

Yes

Yes

Product functionsSecurity

 

 

 

 

Product function

 

 

 

 

  • ACL - port/MAC-based

Yes

Yes

Yes

Yes

  • IEEE 802.1x (radius)

Yes

Yes

Yes

Yes

  • Broadcast/Multicast/Unicast Limiter

Yes

Yes

Yes

Yes

  • broadcast blocking

Yes

Yes

Yes

Yes

Protocol is supported SSH

Yes

Yes

Yes

Yes

Product functionsTime

 

 

 

 

Product function SICLOCK support

Yes

Yes

Yes

Yes

Protocol is supported

 

 

 

 

  • NTP

No

No

No

No

  • SNTP

Yes

Yes

Yes

Yes

  • IEEE 1588 profile default

No

No

No

No

  • IEEE 1588 profile gPTP

-

-

-

-

  • IEEE 1588 profile PSRC

-

-

-

-

Type of time synchronization

-

-

-

-

Standards, specifications, approvals

 

 

 

 

Standard

 

 

 

 

  • for EMC from FM

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

  • for hazardous zone

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

  • for safety of CSA and UL

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

  • for hazardous area of CSA and UL

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

  • for emitted interference

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

  • for interference immunity

EN 61000-6-2:2005

EN 61000-6-2:2005

EN 61000-6-2:2005

EN 61000-6-2:2005

Verification of suitability

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

  • CE mark

Yes

Yes

Yes

Yes

  • C-Tick

Yes

Yes

Yes

Yes

  • Railway application in accordance with EN 50155

-

-

-

-

  • Railway application in accordance with EN 50124-1

-

-

-

-

Marine classification association

 

 

 

 

  • American Bureau of Shipping Europe Ltd. (ABS)

-

-

Yes

Yes

  • Bureau Veritas (BV)

-

-

Yes

Yes

  • Det Norske Veritas (DNV)

-

-

Yes

Yes

  • Germanische Lloyd (GL)

-

-

Yes

Yes

  • Lloyds Register of Shipping (LRS)

-

-

Yes

Yes

  • Nippon Kaiji Kyokai (NK)

-

-

Yes

Yes


Order No.

6GK5 308-2FL00-2AA3

6GK5 308-2FM00-2AA3

6GK5 308-2FN00-2AA3

6GK5 308-2FP00-2AA3

Product type designation

SCALANCE X308-2

SCALANCE X308-2LD

SCALANCE X308-2LH

SCALANCE X308-2LH+

Transmission rate

 

 

 

 

Transfer rate 1

10 Mbit/s

10 Mbit/s

10 Mbit/s

10 Mbit/s

Transfer rate 2

100 Mbit/s

100 Mbit/s

100 Mbit/s

100 Mbit/s

Transfer rate 3

1 000 Mbit/s

1 000 Mbit/s

1 000 Mbit/s

1 000 Mbit/s

Interfaces

 

 

 

 

Number of electrical/optical connections for network components or terminal equipment maximum

10

10

10

10

Number of electrical connections

 

 

 

 

  • for network components and terminal equipment

8

8

8

8

  • for operator console

-

-

-

-

  • for alarm contact

1

1

1

1

  • for media module

-

-

-

-

  • for power supply

1

1

1

1

  • for redundant power supply

2

2

2

2

Design of electrical connection

 

 

 

 

  • for network components and terminal equipment

RJ45 port (1 x 1GE, 7 x FE)

RJ45 port (1 x 1GE, 7 x FE)

RJ45 port (1 x 1GE, 7 x FE)

RJ45 port (1 x 1GE, 7 x FE)

  • for operator console

-

-

-

-

  • for signaling contact

2-pole terminal block

2-pole terminal block

2-pole terminal block

2-pole terminal block

  • for power supply

4-pole terminal block

4-pole terminal block

4-pole terminal block

4-pole terminal block

Number of optical interfaces for optical waveguide

 

 

 

 

  • at 100 Mbit/s

-

-

-

-

  • at 1000 Mbit/s

2

2

2

2

Design of optical interface for optical waveguide

 

 

 

 

  • at 100 Mbit/s

-

-

-

-

  • at 1000 Mbit/s

SC port (multimode up to 0.75 km)

SC port (singlemode up to 10 km)

SC port (singlemode up to 40 km)

SC port (singlemode up to 70 km)

Connectable optical power relative to 1 mW

 

 

 

 

  • of the transmitter output

-9.5 … -4 dB

-9.5 … -3 dB

-6 … +0 dB

0 … 5 dB

  • of the receiver input maximum

-3 dB

-3 dB

-3 dB

-3 dB

Optical sensitivity relative to 1 mW of the receiver input minimum

-17 dB

-21 dB

-23 dB

-23 dB

Attenuation of fiber-optic cable transmission link minimum necessary

0 dB

0 dB

3 dB

8 dB

Range at the optical interface depending on the optical fiber used

0 … 0.75 km

0 … 10 km

8 … 40 km

30 … 70 km

design of the removable storage C-PLUG

Yes

Yes

Yes

Yes

Inputs/outputs

 

 

 

 

Operating voltage of signaling contacts at AC rated value

-

-

-

-

Operating current of signaling contacts at AC maximum

-

-

-

-

Operating voltage of signaling contacts at DC rated value

24 V

24 V

24 V

24 V

Operating current of signaling contacts at DC maximum

0.1 A

0.1 A

0.1 A

0.1 A

Supply voltage, current consumption, power loss

 

 

 

 

Type of supply voltage redundant power supply unit

No

No

No

No

Type of voltage of supply voltage

DC

DC

DC

DC

Supply voltage external

24 V

24 V

24 V

24 V

  • minimum

18 V

18 V

18 V

18 V

  • maximum

32 V

32 V

32 V

32 V

Product component fusing at power supply input

Yes

Yes

Yes

Yes

Type of fusing at input for supply voltage

 

 

 

 

Consumed current maximum

0.4 A

0.4 A

0.4 A

0.4 A

Active power loss

 

 

 

 

  • at 24 V for DC

9.6 W

9.6 W

9.6 W

9.6 W

  • at 230 V AC

-

-

-

-

Permitted ambient conditions

 

 

 

 

Ambient temperature

 

 

 

 

  • during operating

-10 … +60 °C

-40 … +60 °C

-40 … +60 °C

-40 … +60 °C

  • during storage

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

  • during transport

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

  • Comment

-

-

-

-

Relative humidity at 25 °C without condensation during operating maximum

95 %

95 %

95 %

95 %

Ambient condition for (standard) operation mode

-

-

-

-

Protection class IP

IP30

IP30

IP30

IP30

Design, dimensions and weight

 

 

 

 

Design

Compact

Compact

Compact

Compact

Width

120 mm

120 mm

120 mm

120 mm

Height

125 mm

125 mm

125 mm

125 mm

Depth

123 mm

123 mm

123 mm

123 mm

Net weight

1.4 kg

1.4 kg

1.4 kg

1.4 kg

Type of mounting

 

 

 

 

  • Installation 19 inch

No

No

No

No

  • 35 mm DIN rail mounting

Yes

Yes

Yes

Yes

  • wall mounting

Yes

Yes

Yes

Yes

  • S7-300 rail mounting

Yes

Yes

Yes

Yes

Type of mounting

When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted

When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted

When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted

When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted

Product properties, functions, componentsgeneral

 

 

 

 

Cascading in the case of a redundant ring at reconfiguration time of <'~0.3'~s

50

50

50

50

Cascading in cases of star structuring

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Product functionsmanagement, configuration

 

 

 

 

Product function

 

 

 

 

  • CLI

Yes

Yes

Yes

Yes

  • web-based management

Yes

Yes

Yes

Yes

  • MIB support

Yes

Yes

Yes

Yes

  • TRAPs via email

Yes

Yes

Yes

Yes

  • Configuration with STEP 7

Yes

Yes

Yes

Yes

  • RMON

Yes

Yes

Yes

Yes

  • SMTP server

Yes

Yes

Yes

Yes

  • Port mirroring

Yes

Yes

Yes

Yes

  • CoS

Yes

Yes

Yes

Yes

  • for IRT PROFINET IO switch

-

-

-

-

  • PROFINET IO diagnosis

Yes

Yes

Yes

Yes

  • switch-managed

Yes

Yes

Yes

Yes

Protocol is supported

 

 

 

 

  • Telnet

Yes

Yes

Yes

Yes

  • HTTP

Yes

Yes

Yes

Yes

  • HTTPS

Yes

Yes

Yes

Yes

  • TFTP

Yes

Yes

Yes

Yes

  • FTP

Yes

Yes

Yes

Yes

  • BOOTP

Yes

Yes

Yes

Yes

  • SNMP v1

Yes

Yes

Yes

Yes

  • SNMP v2

Yes

Yes

Yes

Yes

  • SNMP v3

Yes

Yes

Yes

Yes

  • IGMP (snooping/querier)

Yes

Yes

Yes

Yes

  • GMRP

Yes

Yes

Yes

Yes

  • DCP

Yes

Yes

Yes

Yes

  • LLDP

Yes

Yes

Yes

Yes

Identification & maintenance

 

 

 

 

  • I&M0 - device-specific information

Yes

Yes

Yes

Yes

  • I&M1 - plant identification/location name

Yes

Yes

Yes

Yes

Product functionsDiagnosis

 

 

 

 

Product function

 

 

 

 

  • Port diagnostics

Yes

Yes

Yes

Yes

  • Statistics Packet Size

Yes

Yes

Yes

Yes

  • Statistics packet type

Yes

Yes

Yes

Yes

  • Error statistics

Yes

Yes

Yes

Yes

  • SysLog

Yes

Yes

Yes

Yes

Product functionsVLAN

 

 

 

 

Product function

 

 

 

 

  • VLAN - port based

Yes

Yes

Yes

Yes

  • VLAN dynamic

Yes

Yes

Yes

Yes

Number of VLANs maximum

255

255

255

255

Number of VLANs - dynamic maximum

255

255

255

255

Protocol is supported GVRP

Yes

Yes

Yes

Yes

Product functionsDHCP

 

 

 

 

Product function

 

 

 

 

  • DHCP client

Yes

Yes

Yes

Yes

  • DHCP Option 82

Yes

Yes

Yes

Yes

  • DHCP Option 66

Yes

Yes

Yes

Yes

  • DHCP Option 67

Yes

Yes

Yes

Yes

Product functionsRedundancy

 

 

 

 

Product function

 

 

 

 

  • Ring redundancy

Yes

Yes

Yes

Yes

  • Redundancy manager

Yes

Yes

Yes

Yes

  • Standby redundancy

Yes

Yes

Yes

Yes

  • HSR redundancy protocol

Yes

Yes

Yes

Yes

  • MRP redundancy protocol

Yes

Yes

Yes

Yes

  • redundancy procedure STP

Yes

Yes

Yes

Yes

  • RSTP redundancy protocol

Yes

Yes

Yes

Yes

  • Passive listening

Yes

Yes

Yes

Yes

Protocol is supported

 

 

 

 

  • STP/RSTP

Yes

Yes

Yes

Yes

  • STP

Yes

Yes

Yes

Yes

  • RSTP

Yes

Yes

Yes

Yes

  • RSTP big network support

Yes

Yes

Yes

Yes

  • LACP

Yes

Yes

Yes

Yes

Product functionsSecurity

 

 

 

 

Product function

 

 

 

 

  • ACL - port/MAC-based

Yes

Yes

Yes

Yes

  • IEEE 802.1x (radius)

Yes

Yes

Yes

Yes

  • Broadcast/Multicast/Unicast Limiter

Yes

Yes

Yes

Yes

  • broadcast blocking

Yes

Yes

Yes

Yes

Protocol is supported SSH

Yes

Yes

Yes

Yes

Product functionsTime

 

 

 

 

Product function SICLOCK support

Yes

Yes

Yes

Yes

Protocol is supported

 

 

 

 

  • NTP

No

No

No

No

  • SNTP

Yes

Yes

Yes

Yes

  • IEEE 1588 profile default

No

No

No

No

  • IEEE 1588 profile gPTP

-

-

-

-

  • IEEE 1588 profile PSRC

-

-

-

-

Type of time synchronization

-

-

-

-

Standards, specifications, approvals

 

 

 

 

Standard

 

 

 

 

  • for EMC from FM

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

  • for hazardous zone

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

  • for safety of CSA and UL

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

  • for hazardous area of CSA and UL

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

  • for emitted interference

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

  • for interference immunity

EN 61000-6-2:2005

EN 61000-6-2:2005

EN 61000-6-2:2005

EN 61000-6-2:2005

Verification of suitability

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

Verification of suitability

 

 

 

 

  • CE mark

Yes

Yes

Yes

Yes

  • C-Tick

Yes

Yes

Yes

Yes

  • Railway application in accordance with EN 50155

-

-

-

-

  • Railway application in accordance with EN 50124-1

-

-

-

-

Marine classification association

 

 

 

 

  • American Bureau of Shipping Europe Ltd. (ABS)

Yes

Yes

Yes

Yes

  • Bureau Veritas (BV)

Yes

Yes

Yes

Yes

  • Det Norske Veritas (DNV)

Yes

Yes

Yes

Yes

  • Germanische Lloyd (GL)

Yes

Yes

Yes

Yes

  • Lloyds Register of Shipping (LRS)

Yes

Yes

Yes

Yes

  • Nippon Kaiji Kyokai (NK)

Yes

Yes

Yes

Yes


Order No.

6GK5 310-0BA00-2AA3

6GK5 310-0FA00-2AA3

6GK5 320-1BD00-2AA3

6GK5 320-3BF00-2AA3

Product type designation

SCALANCE X310FE

SCALANCE X310

SCALANCE X320-1FE

SCALANCE X320-3LD FE

Transmission rate

 

 

 

 

Transfer rate 1

10 Mbit/s

10 Mbit/s

10 Mbit/s

10 Mbit/s

Transfer rate 2

100 Mbit/s

100 Mbit/s

100 Mbit/s

100 Mbit/s

Transfer rate 3

-

1 000 Mbit/s

-

-

Interfaces

 

 

 

 

Number of electrical/optical connections for network components or terminal equipment maximum

10

10

21

23

Number of electrical connections

 

 

 

 

  • for network components and terminal equipment

10

10

20

20

  • for operator console

-

-

-

-

  • for alarm contact

1

1

1

1

  • for media module

-

-

-

-

  • for power supply

1

1

1

1

  • for redundant power supply

2

2

2

2

Design of electrical connection

 

 

 

 

  • for network components and terminal equipment

RJ45 port

RJ45 port (3 x 1GE, 7 x FE)

RJ45 port

RJ45 port

  • for operator console

-

-

-

-

  • for signaling contact

2-pole terminal block

2-pole terminal block

2-pole terminal block

2-pole terminal block

  • for power supply

4-pole terminal block

4-pole terminal block

4-pole terminal block

4-pole terminal block

Number of optical interfaces for optical waveguide

 

 

 

 

  • at 100 Mbit/s

-

-

1

3

  • at 1000 Mbit/s

-

-

-

-

Design of optical interface for optical waveguide

 

 

 

 

  • at 100 Mbit/s

-

-

SC port (multimode up to 5 km)

SC port (1 x multimode up to 5 km, 2 x singlemode up to 26 km)

  • at 1000 Mbit/s

-

-

-

-

Connectable optical power relative to 1 mW

 

 

 

 

  • of the transmitter output

- -

- -

-19 … -14 dB

-15 … -8 dB

  • of the receiver input maximum

-

-

-3 dB

-3 dB

Optical sensitivity relative to 1 mW of the receiver input minimum

-

-

-32 dB

-34 dB

Attenuation of fiber-optic cable transmission link minimum necessary

-

-

0 dB

0 dB

Range at the optical interface depending on the optical fiber used

- -

- -

0 … 5 km

0 … 26 km

design of the removable storage C-PLUG

Yes

Yes

Yes

Yes

Inputs/outputs

 

 

 

 

Operating voltage of signaling contacts at AC rated value

-

-

-

-

Operating current of signaling contacts at AC maximum

-

-

-

-

Operating voltage of signaling contacts at DC rated value

24 V

24 V

24 V

24 V

Operating current of signaling contacts at DC maximum

0.1 A

0.1 A

0.1 A

0.1 A

Supply voltage, current consumption, power loss

 

 

 

 

Type of supply voltage redundant power supply unit

No

No

No

No

Type of voltage of supply voltage

DC

DC

DC

DC

Supply voltage external

24 V

24 V

24 V

24 V

  • minimum

18 V

18 V

18 V

18 V

  • maximum

32 V

32 V

32 V

32 V

Product component fusing at power supply input

Yes

Yes

Yes

Yes

Type of fusing at input for supply voltage

 

 

 

 

Consumed current maximum

0.4 A

0.4 A

0.4 A

0.5 A

Active power loss

 

 

 

 

  • at 24 V for DC

9.6 W

9.6 W

9.6 W

12 W

  • at 230 V AC

-

-

-

-

Permitted ambient conditions

 

 

 

 

Ambient temperature

 

 

 

 

  • during operating

-40 … +60 °C

-40 … +60 °C

-40 … +60 °C

-40 … +60 °C

  • during storage

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

  • during transport

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

  • Comment

-

-

-

-

Relative humidity at 25 °C without condensation during operating maximum

95 %

95 %

95 %

95 %

Ambient condition for (standard) operation mode

-

-

-

-

Protection class IP

IP30

IP30

IP30

IP30

Design, dimensions and weight

 

 

 

 

Design

Compact

Compact

Compact

Compact

Width

120 mm

120 mm

180 mm

180 mm

Height

125 mm

125 mm

125 mm

125 mm

Depth

123 mm

123 mm

123 mm

123 mm

Net weight

1.4 kg

1.4 kg

1.65 kg

1.65 kg

Type of mounting

 

 

 

 

  • Installation 19 inch

No

No

No

No

  • 35 mm DIN rail mounting

Yes

Yes

Yes

Yes

  • wall mounting

Yes

Yes

Yes

Yes

  • S7-300 rail mounting

Yes

Yes

Yes

Yes

Type of mounting

When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted

When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted

When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted

When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted

Product properties, functions, componentsgeneral

 

 

 

 

Cascading in the case of a redundant ring at reconfiguration time of <'~0.3'~s

50

50

50

50

Cascading in cases of star structuring

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Product functionsmanagement, configuration

 

 

 

 

Product function

 

 

 

 

  • CLI

Yes

Yes

Yes

Yes

  • web-based management

Yes

Yes

Yes

Yes

  • MIB support

Yes

Yes

Yes

Yes

  • TRAPs via email

Yes

Yes

Yes

Yes

  • Configuration with STEP 7

Yes

Yes

Yes

Yes

  • RMON

Yes

Yes

Yes

Yes

  • SMTP server

Yes

Yes

Yes

Yes

  • Port mirroring

Yes

Yes

Yes

Yes

  • CoS

Yes

Yes

Yes

Yes

  • for IRT PROFINET IO switch

-

-

-

-

  • PROFINET IO diagnosis

Yes

Yes

Yes

Yes

  • switch-managed

Yes

Yes

Yes

Yes

Protocol is supported

 

 

 

 

  • Telnet

Yes

Yes

Yes

Yes

  • HTTP

Yes

Yes

Yes

Yes

  • HTTPS

Yes

Yes

Yes

Yes

  • TFTP

Yes

Yes

Yes

Yes

  • FTP

Yes

Yes

Yes

Yes

  • BOOTP

Yes

Yes

Yes

Yes

  • SNMP v1

Yes

Yes

Yes

Yes

  • SNMP v2

Yes

Yes

Yes

Yes

  • SNMP v3

Yes

Yes

Yes

Yes

  • IGMP (snooping/querier)

Yes

Yes

Yes

Yes

  • GMRP

Yes

Yes

Yes

Yes

  • DCP

Yes

Yes

Yes

Yes

  • LLDP

Yes

Yes

Yes

Yes

Identification & maintenance

 

 

 

 

  • I&M0 - device-specific information

Yes

Yes

Yes

Yes

  • I&M1 - plant identification/location name

Yes

Yes

Yes

Yes

Product functionsDiagnosis

 

 

 

 

Product function

 

 

 

 

  • Port diagnostics

Yes

Yes

Yes

Yes

  • Statistics Packet Size

Yes

Yes

Yes

Yes

  • Statistics packet type

Yes

Yes

Yes

Yes

  • Error statistics

Yes

Yes

Yes

Yes

  • SysLog

Yes

Yes

Yes

Yes

Product functionsVLAN

 

 

 

 

Product function

 

 

 

 

  • VLAN - port based

Yes

Yes

Yes

Yes

  • VLAN dynamic

Yes

Yes

Yes

Yes

Number of VLANs maximum

255

255

255

255

Number of VLANs - dynamic maximum

255

255

255

255

Protocol is supported GVRP

Yes

Yes

Yes

Yes

Product functionsDHCP

 

 

 

 

Product function

 

 

 

 

  • DHCP client

Yes

Yes

Yes

Yes

  • DHCP Option 82

Yes

Yes

Yes

Yes

  • DHCP Option 66

Yes

Yes

Yes

Yes

  • DHCP Option 67

Yes

Yes

Yes

Yes

Product functionsRedundancy

 

 

 

 

Product function

 

 

 

 

  • Ring redundancy

Yes

Yes

Yes

Yes

  • Redundancy manager

Yes

Yes

Yes

Yes

  • Standby redundancy

Yes

Yes

Yes

Yes

  • HSR redundancy protocol

Yes

Yes

Yes

Yes

  • MRP redundancy protocol

Yes

Yes

Yes

Yes

  • redundancy procedure STP

Yes

Yes

Yes

Yes

  • RSTP redundancy protocol

Yes

Yes

Yes

Yes

  • Passive listening

Yes

Yes

Yes

Yes

Protocol is supported

 

 

 

 

  • STP/RSTP

Yes

Yes

Yes

Yes

  • STP

Yes

Yes

Yes

Yes

  • RSTP

Yes

Yes

Yes

Yes

  • RSTP big network support

Yes

Yes

Yes

Yes

  • LACP

Yes

Yes

Yes

Yes

Product functionsSecurity

 

 

 

 

Product function

 

 

 

 

  • ACL - port/MAC-based

Yes

Yes

Yes

Yes

  • IEEE 802.1x (radius)

Yes

Yes

Yes

Yes

  • Broadcast/Multicast/Unicast Limiter

Yes

Yes

Yes

Yes

  • broadcast blocking

Yes

Yes

Yes

Yes

Protocol is supported SSH

Yes

Yes

Yes

Yes

Product functionsTime

 

 

 

 

Product function SICLOCK support

Yes

Yes

Yes

Yes

Protocol is supported

 

 

 

 

  • NTP

No

No

No

No

  • SNTP

Yes

Yes

Yes

Yes

  • IEEE 1588 profile default

No

No

No

No

  • IEEE 1588 profile gPTP

-

-

-

-

  • IEEE 1588 profile PSRC

-

-

-

-

Type of time synchronization

-

-

-

-

Standards, specifications, approvals

 

 

 

 

Standard

 

 

 

 

  • for EMC from FM

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

  • for hazardous zone

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

  • for safety of CSA and UL

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

  • for hazardous area of CSA and UL

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

  • for emitted interference

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

  • for interference immunity

EN 61000-6-2:2005

EN 61000-6-2:2005

EN 61000-6-2:2005

EN 61000-6-2:2005

Verification of suitability

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

  • CE mark

Yes

Yes

Yes

Yes

  • C-Tick

Yes

Yes

Yes

Yes

  • Railway application in accordance with EN 50155

-

-

-

-

  • Railway application in accordance with EN 50124-1

-

-

-

-

Marine classification association

 

 

 

 

  • American Bureau of Shipping Europe Ltd. (ABS)

Yes

Yes

-

-

  • Bureau Veritas (BV)

Yes

Yes

-

-

  • Det Norske Veritas (DNV)

Yes

Yes

-

-

  • Germanische Lloyd (GL)

Yes

Yes

-

-

  • Lloyds Register of Shipping (LRS)

Yes

Yes

-

-

  • Nippon Kaiji Kyokai (NK)

Yes

Yes

-

-


Order No.

6GK5 308-2GG00-2AA2

6GK5 308-2GG00-2CA2

Product type designation

SCALANCE X308-2M

SCALANCE X308-2M TS

Transmission rate

 

 

Transfer rate 1

10 Mbit/s

10 Mbit/s

Transfer rate 2

100 Mbit/s

100 Mbit/s

Transfer rate 3

1 000 Mbit/s

1 000 Mbit/s

Interfaces

 

 

Number of electrical/optical connections for network components or terminal equipment maximum

8

8

Number of electrical connections

 

 

  • for network components and terminal equipment

4

4

  • for operator console

-

-

  • for alarm contact

1

1

  • for media module

2

2

  • for power supply

1

1

  • for redundant power supply

1

1

Design of electrical connection

 

 

  • for network components and terminal equipment

RJ45 port

RJ45 port

  • for operator console

-

-

  • for signaling contact

2-pole terminal block

2-pole terminal block

  • for power supply

4-pole terminal block

4-pole terminal block

Number of optical interfaces for optical waveguide

 

 

  • at 100 Mbit/s

-

-

  • at 1000 Mbit/s

-

-

Design of optical interface for optical waveguide

 

 

  • at 100 Mbit/s

Dependent on selected media modules

Dependent on selected media modules

  • at 1000 Mbit/s

Dependent on selected media modules

Dependent on selected media modules

Connectable optical power relative to 1 mW

 

 

  • of the transmitter output

- -

- -

  • of the receiver input maximum

-

-

Optical sensitivity relative to 1 mW of the receiver input minimum

-

-

Attenuation of fiber-optic cable transmission link minimum necessary

-

-

Range at the optical interface depending on the optical fiber used

- -

- -

design of the removable storage C-PLUG

Yes

Yes

Inputs/outputs

 

 

Operating voltage of signaling contacts at AC rated value

-

-

Operating current of signaling contacts at AC maximum

-

-

Operating voltage of signaling contacts at DC rated value

24 V

24 V

Operating current of signaling contacts at DC maximum

0.1 A

0.1 A

Supply voltage, current consumption, power loss

 

 

Type of supply voltage redundant power supply unit

No

No

Type of voltage of supply voltage

DC

DC

Supply voltage external

24 V

12 V

  • minimum

18 V

20 V

  • maximum

32 V

30 V

Product component fusing at power supply input

Yes

Yes

Type of fusing at input for supply voltage

 

 

Consumed current maximum

0.7 A

0.7 A

Active power loss

 

 

  • at 24 V for DC

16.6 W

16.6 W

  • at 230 V AC

-

-

Permitted ambient conditions

 

 

Ambient temperature

 

 

  • during operating

-40 … +70 °C

-40 … +70 °C

  • during storage

-40 … +70 °C

-40 … +70 °C

  • during transport

-40 … +70 °C

-40 … +70 °C

  • Comment

Reduced operating temperature through the use of media modules (-40 °C to +70 °C) or SFP plug-in transceivers (-40 °C to +60 °C). If the device is installed in the vertical position, the maximum operating temperature is reduced to +50 °C.

Reduced operating temperature through the use of media modules (-40 °C to +70 °C) or SFP plug-in transceivers (-40 °C to +60 °C). If the device is installed in the vertical position, the maximum operating temperature is reduced to +50 °C.

Relative humidity at 25 °C without condensation during operating maximum

95 %

95 %

Ambient condition for (standard) operation mode

-

-

Protection class IP

IP20

IP20

Design, dimensions and weight

 

 

Design

Compact

Compact

Width

120 mm

120 mm

Height

125 mm

125 mm

Depth

124 mm

124 mm

Net weight

1.4 kg

1.4 kg

Type of mounting

 

 

  • Installation 19 inch

No

No

  • 35 mm DIN rail mounting

Yes

Yes

  • wall mounting

Yes

Yes

  • S7-300 rail mounting

Yes

Yes

Type of mounting

When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted.

When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted.

Product properties, functions, componentsgeneral

 

 

Cascading in the case of a redundant ring at reconfiguration time of <'~0.3'~s

50

50

Cascading in cases of star structuring

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Product functionsmanagement, configuration

 

 

Product function

 

 

  • CLI

Yes

Yes

  • web-based management

Yes

Yes

  • MIB support

Yes

Yes

  • TRAPs via email

Yes

Yes

  • Configuration with STEP 7

Yes

Yes

  • RMON

Yes

Yes

  • SMTP server

Yes

Yes

  • Port mirroring

Yes

Yes

  • CoS

Yes

Yes

  • for IRT PROFINET IO switch

-

-

  • PROFINET IO diagnosis

Yes

Yes

  • switch-managed

Yes

Yes

Protocol is supported

 

 

  • Telnet

Yes

Yes

  • HTTP

Yes

Yes

  • HTTPS

Yes

Yes

  • TFTP

Yes

Yes

  • FTP

Yes

Yes

  • BOOTP

Yes

Yes

  • SNMP v1

Yes

Yes

  • SNMP v2

Yes

Yes

  • SNMP v3

Yes

Yes

  • IGMP (snooping/querier)

Yes

Yes

  • GMRP

Yes

Yes

  • DCP

Yes

Yes

  • LLDP

Yes

Yes

Identification & maintenance

 

 

  • I&M0 - device-specific information

Yes

Yes

  • I&M1 - plant identification/location name

Yes

Yes

Product functionsDiagnosis

 

 

Product function

 

 

  • Port diagnostics

Yes

Yes

  • Statistics Packet Size

Yes

Yes

  • Statistics packet type

Yes

Yes

  • Error statistics

Yes

Yes

  • SysLog

Yes

Yes

Product functionsVLAN

 

 

Product function

 

 

  • VLAN - port based

Yes

Yes

  • VLAN dynamic

Yes

Yes

Number of VLANs maximum

255

255

Number of VLANs - dynamic maximum

255

255

Protocol is supported GVRP

Yes

Yes

Product functionsDHCP

 

 

Product function

 

 

  • DHCP client

Yes

Yes

  • DHCP Option 82

Yes

Yes

  • DHCP Option 66

Yes

Yes

  • DHCP Option 67

Yes

Yes

Product functionsRedundancy

 

 

Product function

 

 

  • Ring redundancy

Yes

Yes

  • Redundancy manager

Yes

Yes

  • Standby redundancy

Yes

Yes

  • HSR redundancy protocol

Yes

Yes

  • MRP redundancy protocol

Yes

Yes

  • redundancy procedure STP

Yes

Yes

  • RSTP redundancy protocol

Yes

Yes

  • Passive listening

Yes

Yes

Protocol is supported

 

 

  • STP/RSTP

Yes

Yes

  • STP

Yes

Yes

  • RSTP

Yes

Yes

  • RSTP big network support

Yes

Yes

  • LACP

Yes

Yes

Product functionsSecurity

 

 

Product function

 

 

  • ACL - port/MAC-based

Yes

Yes

  • IEEE 802.1x (radius)

Yes

Yes

  • Broadcast/Multicast/Unicast Limiter

Yes

Yes

  • broadcast blocking

Yes

Yes

Protocol is supported SSH

Yes

Yes

Product functionsTime

 

 

Product function SICLOCK support

Yes

Yes

Protocol is supported

 

 

  • NTP

No

No

  • SNTP

Yes

Yes

  • IEEE 1588 profile default

Yes

Yes

  • IEEE 1588 profile gPTP

-

-

  • IEEE 1588 profile PSRC

-

-

Type of time synchronization

-

-

Standards, specifications, approvals

 

 

Standard

 

 

  • for EMC from FM

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

  • for hazardous zone

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

  • for safety of CSA and UL

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

  • for hazardous area of CSA and UL

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

  • for emitted interference

EN 61000-6-4:2007 (Class A)

EN 61000-6-4

  • for interference immunity

EN 61000-6-2:2005

EN 61000-6-2

Verification of suitability

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2, EN 61000-6-4

  • CE mark

Yes

Yes

  • C-Tick

Yes

Yes

  • Railway application in accordance with EN 50155

-

Yes

  • Railway application in accordance with EN 50124-1

-

-

Marine classification association

 

 

  • American Bureau of Shipping Europe Ltd. (ABS)

-

-

  • Bureau Veritas (BV)

-

-

  • Det Norske Veritas (DNV)

-

-

  • Germanische Lloyd (GL)

-

-

  • Lloyds Register of Shipping (LRS)

-

-

  • Nippon Kaiji Kyokai (NK)

-

-


Код Заказной номер Описание Вес (кг) Заказать
60603 6AG1308-2FL00-4AA3 siplus net коммутатор scalaнзe x308-2, для тяжёлых условий применения, на основе 6gk5308-2fl00-2aa5 0.75 Заказать
114451 6GK1901-1BB10-2AA0 simatic net ie fc rj45 штекер, 180 rj45, штекерный соединитель с метал. корпусом для пром. условий, предназначен для быстрого монтажа, 180 град. угол вывода кабеля, 1 упаковка = 1 шт. 0.03 Заказать
;