SIMATIC powerrate, as an option for WinCC / PCS 7, ensures transparency in energy consumption from the infeed to the load.
SIMATIC powerrate is used in all sectors in which WinCC or PCS 7 are deployed and energy efficiency considerations play a major role. Total integration into WinCC or PCS 7 means that there is no need for a special system environment. Predefined modules and symbols give you the assurance of building on tested product components, with interfaces that support customized expansion.
SIMATIC powerrate therefore provides a solution that you can use to obtain an overview of the energy consumption of a plant easily and cost-effectively through integration in an existing SIMATIC SCADA system.
SIMATIC powerrate V4.0 | |
---|---|
Hardware requirements | |
SIMATIC powerrate can be used in the PCS 7 or WinCC SCADA environments. For installation, the respective hardware requirements of the following products apply: |
|
Released CPUs - SIMATIC powerrate is released in the PCS 7 environment for: |
|
Released CPUs - SIMATIC powerrate is released in the WinCC SCADA environment for: |
|
Software requirements | |
You can use SIMATIC powerrate in the PCS 7 or WinCC SCADA environments. For installation, the respective software requirements of the following products apply: |
|
The library is released for the following PCS 7 versions: |
|
The library is released for the following WinCC version with the corresponding versions of STEP 7: |
|
For use with WinCC V7.0 SP2, the following installations are required: |
|
powerrate Reports has been released for the following versions: |
|
SIMATIC WinCC powerrate comprises the following components:
Using ready-to-use function blocks, energy data can be acquired by any PROFIBUS-capable devices. The data can be input to the function blocks in the form of counter pulses, count values or power values. Count values can also be entered manually.
From this data, the function block calculates the power averages and the work values for a predefined period. This calculated data is subsequently saved in the WinCC archive. In addition, a final value forecast is extrapolated for the power values for each period.
A sample function (heat calculation) that can be adapted to the needs of the customer at any time by means of open interfaces has been implemented for the purpose of visualizing customized calculations.
Data from manually read counters can be entered directly into the system and used for further analysis. Absolute numerical values (entry of an absolute value instead of the difference from the previous value) can also be recorded and used in further processing.
The up-to-date, acquired energy data is displayed as power averages/work values for each time interval (total value for the previous interval, current value of the current interval, extrapolated value for the end of the current interval). Load curve display enables analysis of archived energy data as well as its tabular representation.
The archived data can be exported to Excel directly from WinCC using the export functions. The exported energy data can also be included in further customized processing. WinCC tools can be used to access the data from the WinCC archive.
For this purpose, selected energy data is read from archives (Tag Logging archive, user archives) from the WinCC Runtime database; using Microsoft Excel the following reports can then be generated:
The generation of exports or reports can be activated manually or automatically time-controlled (daily, weekly or monthly). Data access and report generation can also take place via a separate "office" PC; which enables the WinCC installation and the "office" applications to be distributed across different PCs.
Contractually agreed power limits (in the case of electricity, normally the 15-minute average power value) must be observed, otherwise significantly higher supply prices or even penalty payments may become due to the energy supply company. The load management feature of SIMATIC WinCC powerrate carries out cyclic trend calculations in order to issue warnings/alarms if violation of the limit is likely and to switch off loads in accordance with the given configuration should this be required. If a limit is exceeded despite this, the latest load management data is archived to enable future evaluation or analysis.
To prevent unnecessary switching operations, numerous parameters are available for adapting the load management to the current process conditions - and all this can be done easily and conveniently via the faceplate.
For loads that are distributed over different PLCs, SIMATIC WinCC powerrate contains appropriate PLC-to-PLC communication blocks which can be used to integrate these loads into the load management system. Load management is scalable, according to the maximum number of loads to be integrated or monitored, for up to 10, 25, 50, 75 or 100 loads. Load management can be performed for different media (e.g. electricity, gas) simultaneously.
A batch comprises all the units of a product that have been produced in one production cycle, i.e. under identical conditions. Batch-related consumption recording allows accurate recording of energy consumption for each batch. Batch-related consumption recording is possible for five types of energy each with up to 10 loads. Appropriate reports can be generated for analysis of the data (see also the batch report).
When the SENTRON PAC3200/PAC4200 Power Monitoring Devices are integrated via DPV1 communication, selected measured values can be displayed and alarms (current, voltage, pulse frequency too high) can be generated from the digital status information and displayed.
Switch integration via digital inputs/outputs (DI/DO) supports display of the switch status (On, Off, tripped, unplugged).
With the appropriate authorization, switching is also possible via the faceplate. Switching takes place in a 2-step operation (switch command is issued, followed by a prompt for repeated confirmation; the switch command is not forwarded to the switch until confirmation has been received).
Makes the powerrate functionality available over the Web.
To avoid data loss in the event of a communication fault, the data is stored temporarily in a circulating buffer on the S7.
Further information can be found on the Internet at:
http://www.siemens.com/simatic-powerrate
Important information on the use of SIMATIC powerrate is available on the Internet at:
http://support.automation.siemens.com/WW/view/en/48204134/133200
Код | Заказной номер | Описание | Заказать |
---|---|---|---|
109715 | 6AV6372-1DE04-0AX0 | simatic powerrate v4.0 engineering+ as-rt (unlimited), powermanagement for wincc v7.0 sp2, pcs 7 v7.1 / pcs 7 v7.1 sp1/2, es/rt-sw, single license software + docu on dvd license key on usb stick, class a, 2 languages(ge,en) | Заказать |
109716 | 6AV6372-1DE04-0AX4 | simatic powerrate v4.0 engineering+ as-rt (unlimited), upgrade powerrate v3.x -> v4.0, powermanagement for wincc v7.0 sp2, pcs 7 v7.1 / pcs 7 v7.1 sp1/2, es/rt-sw, single license, software + docu on dvd license key on usb stick, class a, 2 languages(ge,en) | Заказать |
109717 | 6AV6372-1DE04-0AX7 | simatic powerrate v4.0 trial (30 days), powermanagement for wincc v7.0 sp2, pcs 7 v7.1 / pcs 7 v7.1 sp1/2, software + docu on dvd 2 languages(ge,en) | Заказать |