The SINAMICS DC MASTER Control Module is mainly used for retrofitting and modernizing DC drives in existing plants and systems. In DC technology, there are many anterior plants and systems that cannot be connected to modern automation systems.
When such plants and systems are retrofitted or upgraded, the motor, mechanical system and power section are retained and only the closed-loop control section is replaced by a Control Module. As a consequence, an extremely favorably-priced modern DC drive is obtained with the full functional scope of the well-proven, fully digital units from the SINAMICS DC MASTER series.
The new system is adapted to the configuration of the existing components using simple parameterization.
The SINAMICS DC MASTER Control Module contains a power section for the field supply with a rated current of 40 A.
For general technical data, see section "DC Converters"
| Type | |
---|---|---|
| 6RA8000-0MV62-0AA0 | |
Rated armature supply voltage that can be sensed | V | 50/125/250/575/1 000 |
Rated supply voltage, electronics power supply | V | 24 DC (18 … 30 V DC); In = 5 A |
Rated field supply voltage 1) | V | 480 V 2 AC (+10/-20 %) |
Rated frequency | Hz | 45 … 65 |
Rated DC field voltage 1) | V | Max. 390 |
Rated DC field current | A | 40 |
Normal ambient temperature in operation | °C | 0 … +55 |
Dimensions | ||
| mm | 271 |
| mm | 388 |
| mm | 253 |
Weight, approx. | kg | 12 |
1) The field supply voltage can lie below the rated field voltage (set using a parameter, input voltages of up to 85 V are permissible). The output voltage decreases accordingly. The specified DC output voltage can be reliably provided up to a 5 % undervoltage of the line supply voltage (rated field supply voltage).
The SINAMICS DC MASTER Control Module sets itself apart as a result of its compact, space-saving design. The compact design where all of the individual components are easily accessible offers a high degree of service friendliness.
In order to be able to optimally use the mounting and installation possibilities in the plant or system, the SINAMICS DC MASTER Control Module can be split depthwise. In addition, the PC boards for generating and distributing the firing pulses as well as for the fuse monitoring and voltage sensing can be implemented so that they can be mounted outside the unit close to the power section.
Alternatively, when commissioning the drive system with STARTER, the adaptations, settings and measured value displays required can be made using the Basic Operator Panel BOP20 or the Advanced Operator Panel AOP30.
The AOP30 offers a favorably-priced alternative to measuring equipment installed in the electrical cabinet.
The field is supplied from a single-phase, half-controlled bridge circuit B2HZ. The field power section is implemented using electrically insulated thyristor modules, which means that the heatsink is floating.
Note:
When ordering a unit with options, add the suffix “-Z” after the Order No. and then state the order code(s) for the desired option(s) after the suffix.
Examle:
6RA8000-0MV62-0AA0-Z
G00+G20+L10+...
The following table provides an overview of the available options. Detailed descriptions of the options are provided in the section “Description of options”.
Order No. for separate order | ||||
---|---|---|---|---|
Designation | Order code | Notes | not coated | coated |
CUD | ||||
Standard CUD left | (Standard) | – | 6RY1803‑0AA00 | 6RY1803‑0AA20 |
Advanced CUD left | G00 | – | 6RY1803‑0AA05 | 6RY1803‑0AA25 |
Standard CUD right | G10 | This option requires an Advanced CUD left – order code G00 | 6RY1803‑0AA00 | 6RY1803‑0AA20 |
Advanced CUD right | G11 | This option requires an Advanced CUD left – order code G00 | 6RY1803‑0AA05 | 6RY1803‑0AA25 |
Communication Board CBE20 left | G20 | This option requires an Advanced CUD left – order code G00 | – | 6SL3055-0AA00-2EB0 |
Communication Board CBE20 right | G21 | This option requires an Advanced CUD right – order code G11 | – | 6SL3055-0AA00-2EB0 |
Memory card left | S01 | – | 6RX1800-0AS01 | – |
Memory card right | S02 | This option requires a Standard CUD right – order code G10 – or an Advanced CUD right – order code G11 | 6RX1800-0AS01 | – |
Field | ||||
Field power section 1Q | (Standard) | – | – 1) | – 1) |
Field power section 2Q | L11 | – | – 1) | – 1) |
Without field power section | L10 | – | – | – |
Additional options | ||||
Coated PCBs | M08 | – | – | – |
Nickel-plated copper busbars | M10 | – | – | – |
1) Available as spare part.
The SINAMICS DC MASTER Control Module can be split up into several individual modules. These can be mounted separately from one another.
Optional, pre-fabricated cable sets are available to connect the individual modules.
This means that the drive system can be quickly but also flexibly adapted to the plant or system configuration.
Description | Content | Connection | Order No. |
---|---|---|---|
Rear enclosure part including accessories for mounting the firing pulse transformer module and/or fuse monitoring module for a parallel connection | Set of loose parts | 6RY1805‑0CM00 | |
Screws, stud bolts, and snap-on parts to externally mount module parts | Set of loose parts | 6RY1807‑0CM00 | |
Pre-fabricated connection set | 2 x 26-core ribbon cable | from X21A, X22A on PC board -A7109- | 6RY1707‑0CM01 |
1 x 10-core ribbon cable | from X23B on PC board -A7109- | ||
1 x 20-core ribbon cable | from XF1 on PC board -A7109- | ||
1 x RJ45 patch cable | from X45 on PC board -A7109- | ||
Pre-fabricated connection set | 2 x 26-core ribbon cable | from X21A, X22A on PC board -A7109- | 6RY1807‑0CM02 |
1 x 10-core ribbon cable | from X23B on PC board -A7109- | ||
1 x 20-core ribbon cable | from XF1 on PC board -A7109- | ||
1 x RJ45 patch cable | from X45 on PC board -A7109- | ||
Pre-fabricated connection set for | 2 x 2-core twisted cable | from XB on PC board -A7109- | 6RY1707‑0CM03 1) |
Pre-fabricated connection set for | 2 x 2-core cable | from XB on PC board -A7109- | 6RY1707‑0CM04 1) |
Pre-fabricated connection set for | 1 x 2-core cable | from XT6 on PC board -A7109- | 6RY1707‑0CM05 |
Pre-fabricated connection set for | Connection set for 12 x 2-core twisted cable (3 m long) | from XIMP11, XIMP12, XIMP13, XIMP14, XIMP15, XIMP16, XIMP21, XIMP22, XIMP23, XIMP24, XIMP25, | 6RY1707‑0CM06 1) |
Pre-fabricated connection set for | 6 x 2-core twisted cable (10 m long) | from XS1_5, XS2_5, XS3_5, XS4_5, XS5_5, XS6_5, XS7_5, XS8_5, XS9_5, XS10_5, XS11_5, XS12_5 | 6RY1807‑0CM07 |
Pre-fabricated connection set for | 1 x 3-core twisted cable | from XU6, XV6, XW6 or XU5, XV5, XW5 or XU4, XV4, XW4 or XU3, XV3, XW3 or XU2, XV2, XW2 or | 6RY1807‑0CM08 |
Pre-fabricated connection set for | 12 x 2-core twisted cable | from XIMP1, XIMP4 or XIMP2, XIMP5 or XIMP3, XIMP6 on PC board | 6RY1707‑0CM13 1) |
Pre-fabricated connection set for | 2 x 12-core cable | from XIMP1, XIMP4 and/or XIMP2, XIMP5 and/or XIMP3, XIMP6 on PC board -A7043- to the external firing pulse transformers | 6RY1707‑0CM10 1) |
Pre-fabricated connection set for | 2 x 26-core ribbon cable | from X21A, X22A on PC board -A7109- | 6RY1807‑0CM11 |
1 x 10-core ribbon cable | from X23B on PC board -A7109- | ||
1 x 20-core ribbon cable | from XF1 on PC board -A7109- | ||
1 x RJ45 patch cable | from X45 on PC board -A7109- |
1) Unchanged when compared to the SIMOREG DC-MASTER Control Modules.
Код | Заказной номер | Описание | Вес (кг) | Заказать |
---|---|---|---|---|
66748 | 6RA8000-0MV62-0AA0 | sinamics dcm control module without power section incl 40a controllable field rectifier | 12 | Заказать |
115055 | 6RY1707-0CM01 | набор проводов (ленточный кабель): состав: 2 экранированных ленточных кабеля 26-жил (длина=3m) 2 экранированных ленточных кабеля 10-жил (длина=3m) 1 экранированный ленточный кабель 20-жил (длина=3m) | 0.79 | Заказать |
115057 | 6RY1707-0CM03 | набор проводов для трансформаторов тока состав: 2 одножильные витые пары (длина=2m) | 0.12 | Заказать |
66964 | 6RY1707-0CM04 | набор проводов для трансформаторов тока: состав: 2 экранированных двухпроводных кабеля (длина=10m) | 0.3 | Заказать |
115058 | 6RY1707-0CM05 | набор проводов для контроля температуры радиатора: состав: 1 экранированный двухпроводный кабель (длина=10m) | 0.3 | Заказать |
66965 | 6RY1707-0CM06 | набор проводов для d151: состав: 12 одножильных витых пар (устойчивые к короткому замыканию провода) (длина=3m) | 0.62 | Заказать |
115059 | 6RY1707-0CM10 | набор проводов для импульсный трансформатор для управления силовыми модулями: состав: 2 экранированных кабеля 12-жил (длина=10m) | 1.85 | Заказать |
66968 | 6RY1707-0CM13 | набор проводов для импульсного трансформатора для управления силовыми модулями: состав: 12 одножильных витых пар (длина=1m) | 0.3 | Заказать |
115121 | 6RY1805-0CM00 | housing for control module | 5 | Заказать |
115128 | 6RY1807-0CM00 | set of loose parts (required for external use of printed curcuit boards) | 1 | Заказать |
115129 | 6RY1807-0CM02 | set of wires: 2 pieces x ribbon cable shielded 26-way (length=10m) 1 piece x ribbon cable shielded 10-way (length=10m) 1 piece x ribbon cable shielded 20-way (length=10m) 1 piece x rj45 patchcable shielded (length=10m) | 1.2 | Заказать |
67038 | 6RY1807-0CM07 | set of wires for fuse control contents: shielded 26-way (length=3m) 6 pieces single wires (short-circuit-proof cables) twisted pairs (length=10m) | 0.45 | Заказать |
67039 | 6RY1807-0CM08 | set of wires for voltage measurement: content. 1 piece x single wires (short-circuit-proof cables) u-v-w twisted (length=3m) 1 piece single wires (short-circuit-proof cables) c-d twisted (length=3m) | 0.9 | Заказать |
115131 | 6RY1807-0CM11 | set of wires: 2 pieces x ribbon cable 26-way (length=1m) 1 piece x ribbon cable 10-way (length=1m) 1 piece x ribbon cable 20-way (length=1m) 1 piece x rj45 patchcable shielded (length=1m) | 1.3 | Заказать |