SINAMICS S120 Combi Power Module производства Siemens

SINAMICS S120 Combi Power Module

SINAMICS S120 Combi is a very compact and rugged drive system tailored for use in compact turning and milling machines. SINAMICS S120 Combi integrates a line infeed with regenerative feedback capability, power units for spindles and feed motors as well as a TTL encoder interface into a single Power Module.

  • Multi-axis drive module with line infeed capable of regenerative feedback and power units for 3 or 4 axes
  • Drive system tailor-made for use in compact standard turning and milling machines
  • Requires very little mounting space in control cabinet (incl. fan unit, shield connection terminals and ventilation clearances)
  • Optimized for weak supply networks with frequent undervoltage, network imbalances and large frequency fluctuations
  • Optimized for harsh operating conditions with increased cabinet temperature and increased humidity
  • Rugged Power Module resistant to short-circuits, overvoltage and ground faults
  • Rugged and easy-to-fit screw-type terminals with integrated shield connection for the power cables
  • Perfect expandability thanks to additional Motor Modules in booksize compact format
  • Low energy consumption thanks to state-of-the-art 400 V technology
  • Excellent dynamic response and machining precision thanks to Dynamic Servo Control (DSC)
  • Simple cabling thanks to intelligent DRIVE-CLiQ interface
  • Very simple commissioning thanks to predefined topologies

General technical specifications
SINAMICS S120 Combi Power Module

 

DC link voltage

1.35 × line voltage1)

Output voltage

0 ... 0.7 × DC link voltage1)

Line power factor at rated power

 

  • Fundamental power factor (cos φ1)

> 0.96

  • Total (λ)

0.65 … 0.90

Radio interference suppression

 

  • Standard

No radio interference suppression

  • With line filter

Category C2 according to EN 61800‑3

Degree of protection

IP20

Installation altitude

Up to 1000 m (3281 ft) above sea level without derating,
> 1000 ... 4000 m (3281 ... 13124 ft) with derating

Conformity

CE (Low-Voltage and EMC Directives)

Approvals, according to

cURus

Safety Integrated

Safety Integrity Level 2 (SIL 2) according to IEC 61508, Control Category 3 according to EN 954-1


1) The DC link voltage adjusts itself to the mean value of the rectified line voltage.

 

3-axis Power Module

External air cooling

6SL3111-3VE21-6FA0

6SL3111-3VE21-6EA0

6SL3111-3VE22-0HA0

Infeed

16

16

20

20

  • Rated power Prated (S1)

16

16

20

20

  • Infeed power PS6 (S6‑40 %)

21

21

26.5

26.5

  • Peak infeed powerPmax

35

35

40

40

Regenerative feedback

 

 

 

 

  • Rated power Prated (S1)

kW

16

16

20

  • Peak regenerative feedback power Pmax

kW

35

35

40

Supply voltages

 

 

 

 

  • Line voltage

V

380 V 3 AC – 10 % ... 480 V 3 AC + 10 % up to 2000 m above sea level

  • Line frequency

Hz

45 ... 66

  • Electronics power supply

V

24 DC (20.4 ... 28.8 DC)

Rated input current

 

 

 

 

  • At 400 V 3 AC

A

28

28

34

  • At 380 V/480 V 3 AC

A

29/25

29/25

35/30

  • At 400 V 3 AC (S6-40%)

A

35.5

35.5

44

  • Peak current at 400 V 3 AC

A

56

56

63.5

Pulse frequency

kHz

4

4

4

Output voltage AC

V

0 ... 0.7 × DC link voltage

Spindle

A

18

24

30

  • Rated output current AC Irated

A

18

24

30

  • Intermittent-duty operating current ACS6-40%

A

24

32

40

  • Peak current AC Irmax

A

36

48

56

Rated power

 

 

 

 

  • At 540 V DC link voltage

kW

8.7

11.7

14.4

  • At 600 V DC link voltage

kW

9.7

13

16

Feed 1/feed 2

A

5

9

9

  • Rated output current AC Irated

A

5

9

9

  • Intermittent-duty operating current ACS6-40%

A

6.5

12

12

  • Peak current AC Irmax

A

10

18

18

Rated power

 

 

 

 

  • At 540 V DC link voltage

kW

2.4

4.3

4.3

  • At 600 V DC link voltage

kW

2.7

4.8

4.8

Output for expansion axis

 

 

 

 

  • DC link output current DC Irated

A

40

  • DC link voltage DC

V

460 ... 720

  • Electronics output current for an expansion axis 24 V DC

A

20

Electronics current consumption at 24 V DC

 

 

 

 

  • Without external fan module

A

1.5

1.5

1.5

  • With external fan module

A

2.3

2.3

2.3

Total power loss
(incl. electronics losses)

W

425

537

634

  • Internal

W

81

91

102

  • External

W

344

446

532

Ambient temperature, max.

 

 

 

 

  • Without derating

°C (°F)

45 (113)

45 (113)

45 (113)

  • With derating

°C (°F)

55 (131)

55 (131)

55 (131)

DC link voltage DC

V

460 ... 720

  • Overvoltage trip DC

V

820 ± 2 %

  • Undervoltage trip DC

V

380 ± 2 %

DC link capacitance

μF

1645

1880

2115

Circuit breaker (UL)

 

 

 

 

  • Type

 

3VL2105-2KN30-....

3VL2105-2KN30-....

3VL2106-2KN30-....

  • Rated current

A

50

50

60

  • Rated short-circuit current SCCR at 480 V 3 AC, resulting

kA

65

65

65

Safety fuses (UL)

 

 

 

 

  • Type

 

AJT 35

AJT 35

AJT 60

  • Rated current

A

35

35

60

  • Rated short-circuit current SCCR, resulting

 

 

 

 

  • At 480 V 3 AC

kA

65

65

65

  • At 600 V 3 AC

kA

200

200

200

Cooling air requirement

m3/h

160

160

160

Dimensions

 

 

 

 

  • Width

mm (in)

260 (10.24)

260 (10.24)

260 (10.24)

  • Height

mm (in)

380 (14.96)

380 (14.96)

380 (14.96)

  • Depth

mm (in)

304 (11.97)

304 (11.97)

304 (11.97)

Weight, approx.

kg (lb)

18.35 (40.5)

18.4 (40.6)

18.5 (40.8)


 

4-axis Power Module

External air cooling

6SL3111-4VE21-6FA0

6SL3111-4VE21-6EA0

6SL3111-4VE22-0HA0

Infeed

kW

16

16

20

  • Rated power Prated (S1)

kW

16

16

20

  • Infeed power PS6 (S6‑40 %)

kW

21

21

26.5

  • Peak infeed powerPmax

kW

35

35

40

Regenerative feedback

 

 

 

 

  • Rated power Prated (S1)

kW

16

16

20

  • Peak regenerative feedback power Pmax

kW

35

35

40

Supply voltages

 

 

 

 

  • Line voltage

V

380 V 3 AC – 10 % ... 480 V 3 AC + 10 % up to 2000 m above sea level

  • Line frequency

Hz

45 ... 66

  • Electronics power supply

V

24 DC (20.4 ... 28.8 DC)

Rated input current

 

 

 

 

  • At 400 V 3 AC

A

28

28

34

  • At 380 V/480 V 3 AC

A

29/25

29/25

35/30

  • At 400 V 3 AC (S6-40 %)

A

35.5

35.5

44

  • Peak current at 400 V 3 AC

A

56

56

63.5

Pulse frequency

kHz

4

4

4

Output voltage AC

V

0 ... 0.7 × DC link voltage

Spindle

A

18

24

30

  • Rated output current AC Irated

A

18

24

30

  • Intermittent-duty operating current ACS6-40%

A

24

32

40

  • Peak current AC Irmax

A

36

48

56

Rated power

 

 

 

 

  • At 540 V DC link voltage

kW

8.7

11.7

14.4

  • At 600 V DC link voltage

kW

9.7

13

16

Feed 1

A

9

9

12

  • Rated output current AC Irated

A

9

9

12

  • Intermittent-duty operating current ACS6-40%

A

12

12

16

  • Peak current AC Irmax

A

18

18

24

Rated power

 

 

 

 

  • At 540 V DC link voltage

kW

4.3

4.3

5.8

  • At 600 V DC link voltage

kW

4.8

4.8

6.5

Feed 2/feed 3

A

5

9

9

  • Rated output current AC Irated

A

5

9

9

  • Intermittent-duty operating current ACS6-40%

A

6.5

12

12

  • Peak current AC Irmax

A

10

18

18

Rated power

 

 

 

 

  • At 540 V DC link voltage

kW

2.4

4.3

4.3

  • At 600 V DC link voltage

kW

2.7

4.8

4.8

Output for expansion axis

 

 

 

 

  • DC link output current DC Irated

A

40

  • DC link voltage DC

V

460 ... 720

  • Electronics output current for an expansion axis 24 V DC

A

20

Electronics current consumption at 24 V DC

 

 

 

 

  • Without external fan module

A

1.6

1.6

1.6

  • With external fan module

A

2.4

2.4

2.4

Total power loss
(incl. electronics losses)

W

492

607

733

  • Internal

W

87

100

113

  • External

W

405

507

620

Ambient temperature, max.

 

 

 

 

  • Without derating

°C (°F)

45 (113)

45 (113)

45 (113)

  • With derating

°C (°F)

55 (131)

55 (131)

55 (131)

DC link voltage DC

V

460 ... 720

  • Overvoltage trip DC

V

820 ± 2 %

  • Undervoltage trip DC

V

380 ± 2 %

DC link capacitance

μF

1645

2115

2520

Circuit breaker (UL)

 

 

 

 

  • Type

 

3VL2105-2KN30-....

3VL2105-2KN30-....

3VL2106-2KN30-....

  • Rated current

A

50

50

60

  • Rated short-circuit current SCCR at 480 V 3 AC, resulting

kA

65

65

65

Safety fuses (UL)

 

 

 

 

  • Type

 

AJT 35

AJT 35

AJT 60

  • Rated current

A

35

35

60

  • Rated short-circuit current SCCR, resulting

 

 

 

 

  • At 480 V 3 AC

kA

65

65

65

  • At 600 V 3 AC

kA

200

200

200

Cooling air requirement

m3/h

160

160

160

Dimensions

 

 

 

 

  • Width

mm (in)

260 (10.24)

260 (10.24)

260 (10.24)

  • Height

mm (in)

380 (14.96)

380 (14.96)

380 (14.96)

  • Depth

mm (in)

304 (11.97)

304 (11.97)

304 (11.97)

Weight, approx.

kg (lb)

18.9 (41.7)

18.95 (41.8)

19.05 (42)


  • Power Module with 3 or 4 integrated power units
  • Integrated line infeed with regenerative feedback capability
  • Integrated TTL encoder interface
  • Integrated motor brake control for one axis
  • Integrated fan power supply
  • Line connection voltage 380 to 480 V 3 AC
  • Supply types TT, TN and IT
  • Integrated shield connection terminals
  • Heat dissipation concept with an external heat sink for extremely low power loss in the control cabinet
  • Easy-to-mount fan module optimized for harsh environments
  • Increased availability thanks to fan monitoring
  • Derating only from 45 °C cabinet temperature
  • Power cable connection via screw terminals

The following components can be connected to the SINAMICS S120 Combi drive system:

  • SINUMERIK 828D BASIC T
  • SINUMERIK 828D BASIC M
  • SINUMERIK 828D
  • 3 or 4 spindles/feed motors
  • 3 or 4 motor encoders
  • 3 or 4 direct encoders via DMC20
  • Direct spindle encoder directly via TTL or sin/cos via SMC20
  • External fan module
  • Up to two additional Motor Modules in booksize compact format via DC link connection and 24 V DC busbars
  • Braking Module with braking resistor via DC link connection1)
  • Control Supply Module via DC link connection and 24 V DC busbars1)
  • One safe motor brake control
  • 5 or 6 DRIVE-CLiQ sockets
  • 24 V electronics power supply via connector
  • 1 safe standstill input for the infeed (enable pulses)
  • 1 safe standstill input for the spindle and feeds (enable pulses)
  • 1 temperature sensor input for the spindle (KTY84-130 or PTC)
  • PE/protective conductor connections

The scope of supply of the SINAMICS S120 Combi Power Modules includes:

  • SINAMICS S120 Combi Power Module
  • Accessories pack comprising:
    • 4 DRIVE-CLiQ dust-proof blanking plugs
    • Connector X224 for electronics power supply
    • Connector X11 for motor brake control
    • Connector X21 enable pulses infeed
    • Connector X22 enable pulses drives/temp.
    • 5 shield connection terminals for power cables
    • Shield connection terminal for signal cable

1) For information about the Braking Module and Control Supply Module, please refer to Catalog NC 61 or the Siemens Industry Mall.

Код Заказной номер Описание Вес (кг) Заказать
48959 3VL2105-2KN30-.... авт. выключатель vl 150 ul; тип dg (cat no. hdx3b050) non-interchangeable frame w. approbation авт. выключатель to ul489 высок.откл.спос. 3-полюса, nema rating 65ka/480v, (molded case авт. выключатель) расцепитель tm, li tu= 40 degr. celsius in= < 50a, rated current ii= 450...700a short-circuit protection ir= 50a макс.расц. f. plant protection w/o connection аксессуар 2.2 Заказать
48975 3VL2106-2KN30-.... авт. выключатель vl 150 ul; тип dg (cat no. hdx3b060) non-interchangeable frame w. approbation авт. выключатель to ul489 высок.откл.спос. 3-полюса, nema rating 65ka/480v, (molded case авт. выключатель) расцепитель tm, li tu= 40 degr. celsius in= < 60a, rated current ii= 450...700a short-circuit protection ir= 60a макс.расц. f. plant protection w/o connection аксессуар 2.2 Заказать
115834 6SL3111-3VE21-6EA0 sinamics s120 combi силовой модуль вход: dc 400в, 16квт выход: 3ac 400в, 24a, 9a, 9a исполнение: combi внешнее воздушное охлаждение поддержка расширенных встроенных функций безопасности 18.4 Заказать
67765 6SL3111-3VE21-6FA0 sinamics s120 силовой модуль вход: ac 400в выход: 3ac 400в, 18a, 5a, 5a исполнение: combi внешнее воздушное охлаждение поддержка расширенных встроенных функций безопасности 18.35 Заказать
115835 6SL3111-3VE22-0HA0 sinamics s120 силовой модуль combi вход: dc 400в, 20квт выход: 3ac 400в, 30a, 9a, 9a исполнение: combi внешнее воздушное охлаждение поддержка расширенных функций safety integrated 18.5 Заказать
67766 6SL3111-4VE21-6EA0 sinamics s120 combi силовой модуль вход: dc 400в, 16квт выход: 3ac 400в, 24a, 9a, 9a исполнение: combi внешнее воздушное охлаждение поддержка расширенных функций safety integrated 18.95 Заказать
115836 6SL3111-4VE21-6FA0 sinamics s120 combi силовой модуль вход: dc 400в, 16квт выход: 3ac 400в, 18a,9a,5a,5a исполнение: combi внешнее воздушное охлаждение поддержка расширенных функций safety integrated 18.9 Заказать
67767 6SL3111-4VE22-0HA0 sinamics s120 combi силовой модуль вход: dc 400в, 20квт выход: 3ac 400в,30a,12a,9a,9a исполнение: combi внешнее воздушное охлаждение поддержка расширенных функций safety integrated 19.05 Заказать
115878 6SL3161-8AP00-0AA0 sinamics s120 combi набор 24в dc штекер 2-полюсный штекер для тормоза двигателя drive-cliq заглушка на место установки (3) сигнальные штекеры x11/x12/x21/x22 экранные зажимы (5 шт.) профиль кодирования x11/x12/x21/x22 защитный фиксатор x11/x12/x21/x22 информационный вкладыш 0.05 Заказать
;