Loher frequency inverters for elevators, DYNAVERT L guarantee the highest degree of reliability and travel comfort.
Depending on the particular requirement, they can be flexibly used for supply voltages extending from 230 V to 500 V. They can control both synchronous as well as induction motors.
DYNAVERT L units are efficient, easy to handle and can be used for elevator systems with ratings of up to 105 kW. They are state-of-the-art fully digitized voltage-source DC link converters equipped with fourth generation IGBTs.
Their equipping means that they can be easily used in all operating environments – even in hospitals and chemical plants.
Today, elevator drives are designed either as gearless or as geared solutions. The requirements of the respective elevator system influence which variant is selected. Loher DYNAVERT L is therefore used in both systems: DYNASYS S (gearless) and DYNASYS G (geared).
Rated input voltage | Typ. rated motor power of the units |
---|---|
400 V | 2 - 105 kW |
500 V | 2 - 105 kW |
1~AC 230V supply - using either UPS or 100V - 400V DC from a battery possible, for evacuation operation when the line supply fails |
Brief overview | |
---|---|
Setting, diagnostics | Operator panel connected to Dynavert L, LEDs, serial interface |
Control commands | Contacts or 24 V control signals (PLC-compatible for travel commands and other digital input), DCP interface |
Motor types | Synchronous / induction – gearless or with gear |
Signal outputs: | Isolated contacts, 250 V AC /1A, DCP interface |
Speed feedback for synchronous motors | 1 V-PP signal level (max. 10 m encoder cable) |
Speed feedback for induction motors | Encoder with HTL signal level or TTL signal level, the pulse number can be parameterized, |
Open-loop operation | Possible with induction motors up to 1.2 m/s elevator cabin speed |
Mechanical degree of protection | IP20 |
Ambient temperature, storage | -25 … +70 °C |
Ambient temperature, operation | 0 … + 45 °C |
Installation height | 1000 m above sea level; above this altitude, the drive unit utilization must be reduced by 10 % for every 1000 m |
Cooling | Direct forced air cooling, automatic temperature control |
Код | Заказной номер | Описание | Вес (кг) | Заказать |
---|---|---|---|---|
67186 | 6SE0202-1AA21-6AA6 | dynavert l 2l2w05400-016 3ac 230-415 v,tn/tt 50/60hz max. current 16a, compact devic free variable drive graph integr. brake chopper mains filter cl.a acc.toen55011 | 13 | Заказать |
67187 | 6SE0202-1AA22-5AA6 | dynavert l 2l2w05400-025 3ac 230-415 v,tn/tt 50/60hz max. current 25a, compact devic free variable drive graph integr. brake chopper mains filter cl.a acc.toen55011 | 14 | Заказать |
115275 | 6SE0202-1AA24-0AA6 | dynavert l 2l2w05400-040 3ac 230-415 v,tn/tt 50/60hz max. current 40 a, compact devi free variable drive graph integr. brake chopper mains filter cl.a acc.toen55011 | 18 | Заказать |
67188 | 6SE0202-1AA26-2AA6 | dynavert l 2l2w05400-062 3ac 230-415 v,tn/tt 50/60hz max. current 62 a, compact devi free variable drive graph integr. brake chopper mains filter cl.a acc.toen55011 | 20 | Заказать |
67189 | 6SE0202-1AA27-5AA5 | dynavert l 2l2w05400-075 3ac 230-500v,tn/tt 50/60hz max. current 75a compact device free variable drive graph integr. breake resistor mains filter cl.a acc.toen55011 integr.drive contactor 230 v ac | 36 | Заказать |
115276 | 6SE0202-1AA28-8AA6 | dynavert l 2l2a06400-090 3ac 230-500v,tn/tt 50/60hz max. current 90a compact device free variable drive graph mains filter cl.a acc.toen55011 | 48 | Заказать |
115277 | 6SE0202-1AA31-3AA6 | dynavert l 2l2a06400-130 3ac 230-500v,tn/tt 50/60hz max. current 130a compact device free variable drive graph mains filter cl.a acc.toen55011 | 52 | Заказать |
67190 | 6SE0202-1AA31-7AA6 | dynavert l 2l2a06400-170 3ac 230-500v,tn/tt 50/60hz max. current 170a compact device free variable drive graph mains filter cl.a acc.toen55011 | 81 | Заказать |
67191 | 6SE0202-1AA32-1AA6 | dynavert l 2l2a06400-210 3ac 230-500v,tn/tt 50/60hz max. current 210a compact device free variable drive graph mains filter cl.a acc.toen55011 | 85 | Заказать |
115278 | 6SE0202-1AA32-5AA6 | dynavert l 2l2a06400-250 3ac 230-500v,tn/tt 50/60hz max. current 250a compact device free variable drive graph mains filter cl.a acc.toen55011 | 87 | Заказать |
67192 | 6SE0202-1AB22-5AA6 | dynavert l 2l2a06500-025 3ac 230-500v,tn/tt/it 50/60hz max. current 25a compact device free variable drive graph | 15 | Заказать |
67193 | 6SE0202-1AB25-0AA6 | dynavert l 2l2a06500-050 3ac 230-500v,tn/tt/it 50/60hz max. current 50a compact device free variable drive graph | 32 | Заказать |
115279 | 6SE0202-1AB28-8AA6 | dynavert l 2l2a06500-090 3ac 230-500v,tn/tt/it 50/60hz max. current 90a compact device free variable drive graph | 51 | Заказать |
115280 | 6SE0202-1AB31-3AA6 | dynavert l 2l2a06500-130 3ac 230-500v,tn/tt/it 50/60hz max. current 130a compact device free variable drive graph | 55 | Заказать |
115281 | 6SE0202-1AB31-7AA6 | dynavert l 2l2a06500-170 3ac 230-500v,tn/tt/it 50/60hz max. current 170a compact device free variable drive graph | 90 | Заказать |
67194 | 6SE0202-1AB32-1AA6 | dynavert l 2l2a06500-210 3ac 230-500v,tn/tt/it 50/60hz max. current 210a compact device free variable drive graph | 94 | Заказать |
67195 | 6SE0202-1AB32-5AA6 | dynavert l 2l2a06500-250 3ac 230-500v,tn/tt/it 50/60hz max. current 250a compact device free variable drive graph | 96 | Заказать |