RFID 3SE63 contactless safety switches meet the highest safety requirements, SIL3 or Cat. 4, for monitoring the positions of movable protective devices.

An RFID safety switch consists of a coded RFID switch with an 8-pole M12 connector plug and an identical RFID actuator.

The switch is available in several versions:

  • Family coded with M12 plug or with additional 18 N magnetic catch as an option
  • Individually coded, programmable once, with M12 plug or with additional 18 N magnetic catch as an option
  • Individually coded, programmable more than once (an unlimited number of times), with M12 plug or variant with additional 18 N magnetic catch

The actuator is therefore available in two versions:

  • Standard
  • With 18 N magnetic catch

The magnetic catch keeps doors and flaps closed with permanent magnets.

Optional accessories

Covers for sealing mounting holes, also suitable for tamper-proofing screw fixings

Spacers (approx. 3 mm high) to facilitate cleaning under the installation surface when using pressure washers, for example

Mounting and maintenance

Reduction in the number of versions, because

  • switches can be mounted on right or left sides
  • the actuator can be mounted on all sides

Quick and easy mounting by thanks to universal mounting holes

  • Standard gauge/holes for 3SE6 magnetically operated switch
  • Fine adjustment thanks to slotted holes

Little adjustment or maintenance required

  • Threshold indication by LED switch for quick and easy adjustment during installation and maintenance
  • Molded switch allows it to be used as an end stop for small and medium-sized doors

Note:

Keep metal parts and cuttings away from the vicinity of the switch

Minimum distance between two switches 100 mm

Coding

Family coded

These safety switches are delivered ready to use, i. e. no programming is necessary.

Individually coded, programmable once

The assignment of safety switch and actuator thus created is irreversible.

The actuator is programmed simply by routine during startup, thus permanently preventing any form of tampering by means of a replacement actuator.

Individually coded, programmable several times

The procedure for programming a new actuator can be repeated an unlimited number of times. When a new actuator is programmed the previous code becomes invalid. A protected coding process allows new actuators to be programmed for service purposes.

After this, a ten-minute lockout provides enhanced tamper protection. The green LED flashes until the lockout time has ended and the new actuator has been detected. If the operational voltage is interrupted during this time, the ten-minute guard time is restarted.

Programming procedure for individual coding

1. Apply operational voltage to safety sensor

2. Move actuator into detecting range: red LED lights up, yellow LED flashes (1 Hz)

3. After 10 s it changes to a shorter flashing frequency (3 Hz). In this state switch off operational voltage.

4. After the next time the operational voltage is switched on, the actuator is detected again to activate the programmed actuator code. The activated code is thus stored permanently.

Diagnostics

The RFID safety switch indicates its operating state including faults by means of the LED indicator in the switch and the short circuit-resistant diagnostic output. The signals can then be used for central displays or non-safety-related control tasks.

There are two diagnostics functions:

  • Crossover monitoring
  • Open-circuit monitoring
  • External voltage monitoring
  • Ambient temperature too high
  • Wrong or defective actuator
  • Switching interval threshold identification with LED indication

The signal combination "diagnostics output switched off" and "safety outputs still switched on" can be used to move the machine into a controlled stop position.

Any crossover or a fault that is not currently compromising the safe operation of a safety switch results in the disconnection of the safety channels after a 30 minute delay. However, the diagnostics output switches off instantaneously.

Mode of operation of the diagnostics LEDs

The safety switch indicates not only its operating state, but also faults by means of LEDs in three colors at the ends of the RFID switch.

  • The green LED indicates readiness for operation when the control supply voltage is connected.
  • The yellow LED indicates that there is an actuator in detecting range. If the actuator is in the switching interval threshold, this is indicated by flashing. This flashing can be used to identify a change in the distance between sensor and actuator at an early stage (e. g. as a result of the sagging of a protective door). The installation should be tested before the distance increases further, the safety outputs switch off and the machine stops.
  • The red LED indicates the individual causes of the fault by means of defined flashing frequencies.

RFID contactless safety switches are designed for use in safety circuits, and are used to monitor the positions of movable protective devices. They monitor the positions of rotating, laterally sliding or removable protective devices using the coded electronic actuator.

Their high degree of protection (IP69K) and the use of cleaning product-resistant materials means that these switches are optimized for use under extreme environmental conditions.

Their electronic operating principle makes these switches ideal for metalworking machinery.

The switches have a larger switching interval and switching displacement than mechanical switches, improve the mounting tolerance of the protective door, and offer a wide range of diagnostics options.

The RFID switches can be connected to all standard evaluation units, e. g. an SPS, 3TK28 safety evaluation units (in which the built-in crossover monitoring function can be deactivated), or the 3RK3 modular safety system.

The following safety categories can be achieved in safety circuits:

  • Category 4 according to EN ISO 13849-1 (EN 954-1)
  • PL e according to EN ISO 13849-1
  • SIL 3 according to IEC 61508
  • Maximum tamper resistance by means of individual coding of switches and actuators at the highest safety level
  • Plastic enclosure with integrated connector
  • 2 electronic short circuit proof safety outputs, each 250 mA
  • Integrated crossover, open circuit and external voltage monitoring, with series circuit as far as the control cabinet
  • Safety and diagnostics signals can be connected in series
  • Series connection of safety circuits in Cat. 4 / PL e / SIL 3
  • LED status indication including switching interval threshold indication for quick and easy adjustment during installation and maintenance
  • short circuit proof conventional diagnostics output
  • Optional version with magnetic catch for interlocking hatches or small doors even when de-energized
  • Highly rugged thanks to the use of tested enclosure materials, resistant to aggressive cleaning products, with a degree of protection of up to IP69K
  • Fine adjustment thanks to slotted holes
  • Little adjustment or maintenance required
  • Molded switch allows it to be used as an end stop for small and medium-sized doors
  • Вес (кг) : 0.165
Код Заказной номер Описание Заказать
97455 3SE6310-0BC01 standard actuator for all rfid safety switches rectangular 25mm x 91mm, without magnetic latching Заказать
97456 3SE6310-1BC01 actuator with magnetic latching 18n for rfid safety switches rectangular 25mm x 91mm, with magnetic latching Заказать
47100 3SE6315-0BB01 rfid non-contact safety switch rectangular 25mm x 91mm, family-coded with m12 connector 8-pole delivery state: ready for operation, order actuator separately 3se6310-0bc01 Заказать
47101 3SE6315-0BB02 rfid non-contact safety switch rectangular 25mm x 91mm, individually coded, multiple teach-in capability with m12 connector 8-pole order actuator separately 3se6310-0bc01 Заказать
47102 3SE6315-0BB03 rfid non-contact safety switch rectangular 25mm x 91mm, individually coded, single teach-in capability with m12 connector 8-pole order actuator separately 3se6310-0bc01 Заказать
47103 3SE6315-1BB01 rfid non-contact safety switch rectangular 25mm x 91mm, family-coded with m12 connector 8-pole and magnetic latching delivery state: ready for operation, actuator with magnetic latching 18 n, order separately 3se6310-1bc01 Заказать
47104 3SE6315-1BB02 rfid non-contact safety switch rectangular 25mm x 91mm, ndividually coded, multiple teach-in capability with m12 connector 8-pole and magnetic latching, order actuator separately 3se6310-1bc01 Заказать
47105 3SE6315-1BB03 rfid non-contact safety switch rectangular 25mm x 91mm, ndividually coded, single teach-in capability with m12 connector 8-pole and magnetic latching, order actuator separately 3se6310-1bc01 Заказать
47203 3SX5600-1G caps and spacers for rfid safety switch 3se63, comprising 8x caps for mounting holes and 4x seal washers 3mm high, suitable as spacer for cleaning purposes under the mounting surface Заказать
97571 3SX5601-2GA03 cable, 8-pin, free cable end 3m long, for rfid safety switch 3se63, on straight socket m12, for 2a and 30v Заказать
97572 3SX5601-2GA05 cable, 8-pin, free cable end 5m long, for rfid safety switch 3se63, on straight socket m12, for 2a and 30v Заказать
97573 3SX5601-2GA10 cable, 8-pin, free cable end 10m long, for rfid safety switch 3se63, on straight socket m12, for 2a and 30v Заказать
;