RFID 3SE63 contactless safety switches meet the highest safety requirements, SIL3 or Cat. 4, for monitoring the positions of movable protective devices.
An RFID safety switch consists of a coded RFID switch with an 8-pole M12 connector plug and an identical RFID actuator.
The switch is available in several versions:
The actuator is therefore available in two versions:
The magnetic catch keeps doors and flaps closed with permanent magnets.
Covers for sealing mounting holes, also suitable for tamper-proofing screw fixings
Spacers (approx. 3 mm high) to facilitate cleaning under the installation surface when using pressure washers, for example
Reduction in the number of versions, because
Quick and easy mounting by thanks to universal mounting holes
Little adjustment or maintenance required
Note:
Keep metal parts and cuttings away from the vicinity of the switch
Minimum distance between two switches 100 mm
Family coded
These safety switches are delivered ready to use, i. e. no programming is necessary.
Individually coded, programmable once
The assignment of safety switch and actuator thus created is irreversible.
The actuator is programmed simply by routine during startup, thus permanently preventing any form of tampering by means of a replacement actuator.
Individually coded, programmable several times
The procedure for programming a new actuator can be repeated an unlimited number of times. When a new actuator is programmed the previous code becomes invalid. A protected coding process allows new actuators to be programmed for service purposes.
After this, a ten-minute lockout provides enhanced tamper protection. The green LED flashes until the lockout time has ended and the new actuator has been detected. If the operational voltage is interrupted during this time, the ten-minute guard time is restarted.
Programming procedure for individual coding
1. Apply operational voltage to safety sensor
2. Move actuator into detecting range: red LED lights up, yellow LED flashes (1 Hz)
3. After 10 s it changes to a shorter flashing frequency (3 Hz). In this state switch off operational voltage.
4. After the next time the operational voltage is switched on, the actuator is detected again to activate the programmed actuator code. The activated code is thus stored permanently.
The RFID safety switch indicates its operating state including faults by means of the LED indicator in the switch and the short circuit-resistant diagnostic output. The signals can then be used for central displays or non-safety-related control tasks.
There are two diagnostics functions:
The signal combination "diagnostics output switched off" and "safety outputs still switched on" can be used to move the machine into a controlled stop position.
Any crossover or a fault that is not currently compromising the safe operation of a safety switch results in the disconnection of the safety channels after a 30 minute delay. However, the diagnostics output switches off instantaneously.
Mode of operation of the diagnostics LEDs
The safety switch indicates not only its operating state, but also faults by means of LEDs in three colors at the ends of the RFID switch.
RFID contactless safety switches are designed for use in safety circuits, and are used to monitor the positions of movable protective devices. They monitor the positions of rotating, laterally sliding or removable protective devices using the coded electronic actuator.
Their high degree of protection (IP69K) and the use of cleaning product-resistant materials means that these switches are optimized for use under extreme environmental conditions.
Their electronic operating principle makes these switches ideal for metalworking machinery.
The switches have a larger switching interval and switching displacement than mechanical switches, improve the mounting tolerance of the protective door, and offer a wide range of diagnostics options.
The RFID switches can be connected to all standard evaluation units, e. g. an SPS, 3TK28 safety evaluation units (in which the built-in crossover monitoring function can be deactivated), or the 3RK3 modular safety system.
The following safety categories can be achieved in safety circuits:
Код | Заказной номер | Описание | Заказать |
---|---|---|---|
97455 | 3SE6310-0BC01 | standard actuator for all rfid safety switches rectangular 25mm x 91mm, without magnetic latching | Заказать |
97456 | 3SE6310-1BC01 | actuator with magnetic latching 18n for rfid safety switches rectangular 25mm x 91mm, with magnetic latching | Заказать |
47100 | 3SE6315-0BB01 | rfid non-contact safety switch rectangular 25mm x 91mm, family-coded with m12 connector 8-pole delivery state: ready for operation, order actuator separately 3se6310-0bc01 | Заказать |
47101 | 3SE6315-0BB02 | rfid non-contact safety switch rectangular 25mm x 91mm, individually coded, multiple teach-in capability with m12 connector 8-pole order actuator separately 3se6310-0bc01 | Заказать |
47102 | 3SE6315-0BB03 | rfid non-contact safety switch rectangular 25mm x 91mm, individually coded, single teach-in capability with m12 connector 8-pole order actuator separately 3se6310-0bc01 | Заказать |
47103 | 3SE6315-1BB01 | rfid non-contact safety switch rectangular 25mm x 91mm, family-coded with m12 connector 8-pole and magnetic latching delivery state: ready for operation, actuator with magnetic latching 18 n, order separately 3se6310-1bc01 | Заказать |
47104 | 3SE6315-1BB02 | rfid non-contact safety switch rectangular 25mm x 91mm, ndividually coded, multiple teach-in capability with m12 connector 8-pole and magnetic latching, order actuator separately 3se6310-1bc01 | Заказать |
47105 | 3SE6315-1BB03 | rfid non-contact safety switch rectangular 25mm x 91mm, ndividually coded, single teach-in capability with m12 connector 8-pole and magnetic latching, order actuator separately 3se6310-1bc01 | Заказать |
47203 | 3SX5600-1G | caps and spacers for rfid safety switch 3se63, comprising 8x caps for mounting holes and 4x seal washers 3mm high, suitable as spacer for cleaning purposes under the mounting surface | Заказать |
97571 | 3SX5601-2GA03 | cable, 8-pin, free cable end 3m long, for rfid safety switch 3se63, on straight socket m12, for 2a and 30v | Заказать |
97572 | 3SX5601-2GA05 | cable, 8-pin, free cable end 5m long, for rfid safety switch 3se63, on straight socket m12, for 2a and 30v | Заказать |
97573 | 3SX5601-2GA10 | cable, 8-pin, free cable end 10m long, for rfid safety switch 3se63, on straight socket m12, for 2a and 30v | Заказать |